This document is derived from three reviewed papers by the same authors: (1)Elastic properties of a tungsten-silver composite by reconstruction and computation...
Although fiber reinforced polymer (FRP) composites are increasingly being used for the renewal of civil infrastructure, there are still some major questions...
Charles J. Burroughs, Samuel Benz, Todd E. Harvey, H. Sasaki
We have made several improvements to the NIST Josephson FRDC (fast reversed dc) source so that it now operates at 1 Volt. We have made a precision comparison to...
Samuel Benz, Laurie Christian, Charles J. Burroughs, Clark A. Hamilton
We have synthesized and measured dc voltages using a bipolar pulse-quantized Josephson voltage waveform synthesizer. Bias current ranges were determined for 101...
Chriss A. Jones, John H. Grosvenor Jr, Claude Weil
We report the development of a 76.84 mm (3.025 in) diameter coaxial air line system whose purpose is to measure the dielectric and magnetic properties of bulk...
As electronic signals move to higher frequencies and wider bandwidths, there is need for new methods of measuring these bandwidths, there is need for new...
X. Han, Gerard N. Stenbakken, F. J. Von Zuben, Hans Engler
This paper explores the neural network approach for empirical nonlinear error modeling. For systems that have a significant amount of nonlinearity, nonlinear...
D. Reymann, Thomas J. Witt, P. Vrabcek, Yi-hua D. Tang, Clark A. Hamilton, A. S. Katkov, Blaise Jeanneret, O. Power
The BIPM carries out a number of comparisons of DC voltage standards with National Metrology Institutes. These take the form of on-site comparisons of Josephson...
We report long-term measurements of the charge offset Q 0 in SET (single-electron tunneling) transistors, made of Al/AlO x/Al tunnel junctions. In one case, we...
A Complete characterization of Zener standards for temperature, pressure, and humidity is being performed to improve the uncertainty of a MAP that uses 10 V...
Richard L. Steiner, David B. Newell, J. Schwarz, Edwin R. Williams, Ruimin Liu
The NIST electronic kilogram experiment is being completely rebuilt into a vaccum chamber within a specially designed laboratory room. Major renovations include...
Bryan C. Waltrip, Owen B. Laug, Gerard N. Stenbakken
An improved gated-oscillator time-base and associated auto-calibration algorithm for use in a high-accuracy sampling waveform acquistion system are described...
Thomas F. Wunsch, Joseph R. Kinard Jr., Ronald R. Manginell, O. M. Solomon, Thomas E. Lipe Jr.
Advanced thin flm processing and packaging technologies are employed in the fabrication of new planar thin-film multijunction thermal converters. The processing...
Piotr S. Filipski, C. J. van Mullem, D. Janik, M. Klonz, Joseph R. Kinard Jr., Thomas E. Lipe Jr., Bryan C. Waltrip
The paper summarizes results of two international comparisons relating TVC RF voltage transfer standards of the National Research Council of Canada (NRC) to the...
Randolph Elmquist, Anne-Marie Jeffery, Dean G. Jarrett
Coaxial straight-wire resistance standards with calculable frequency dependence have been used to tie alternating-current (ac) measurements to direct-current...
Nile M. Oldham, Thomas L. Nelson, R. Bergeest, R. Carranza, M. Gibbes, K Jones, Gregory Kyriazis, H. Laiz, L. Liu, Z. Lu, U. Pogliano, K. E. Rydler, E. Shapiro, E. So, M. Temba, P. Wright
An International Comparison of 50/60 Hz Power is described. The traveling standard was an electronic power transducer which was tested at 120 volts, 5 amperes...
A new deconvolution approach is described for reconstructing fast step-like or impulsive signals that have been measured with a sampling oscilloscope for which...
Anne-Marie Jeffery, John Q. Shields, Scott H. Shields
A 4-terminal-pair ac bridge, capable of a relative uncertainty of 2 x 10^-9^, has been constructed at NIST. The bridge is a multi-ratio bridge (10:1, 2:1 and 1...
The amplitude and bandwidth of kick-out pulses used in the nose-to-nose sampler impulse response characterization method were measured as a function of offset...
Two JVS systems operated at the NIST and LMA were compared by using four traveling Zener standards. A MAP protocol was adopted for the comparison. The mean...
Joy Dunkers, M J. Everett, D P. Sanders, Donald L. Hunston
The Composites Group at the National Institute of Standards and Technology has found optical coherence tomography (OCT) to be a powerful tool for non...
The effect of cyclic hygrothermal aging on a particle-filled, epoxy-based adhesive was studied using a sequence of water absorption, desorption and reabsorption...
Gale A. Holmes, Donald L. Hunston, Walter G. McDonough, R C. Peterson
Two of the critical factors controlling the long-term performance and durability of composites in structural applications is the fiber-matrix interfacial shear...
Motohisa Kanda, Dennis G. Camell, J. Achkar, M. Alexander, Jan P. deVreede, Michele Borsero, H. Yajima, N. S. Chung, H. Trzaska
This paper descirbes the international comparison of electric field strength measurements at frequencies between 27 MHz and 10 GHz (GT/RF 86-1). The...
Jerzy Krupka, James R. Baker-Jarvis, Richard G. Geyer
The permittivity and dielectric loss tangent of bulk strontium titanate were measured from 4 to 3pp K, at frequencies from 400 MHz to 3.8 GHz, using a...
S Bird, D Day, John S. Garofolo, J Henderson, Christophe Laprun, M Liberman
We describe a formal model for annotating linguistic artifacts, from which we derive an application programming interface (API) to a suite of tools for...
S R. Kueh, Richard~undefined~undefined~undefined~undefined~undefined Parnas, Joy Dunkers, S G. Advanti, P S. Furrows, M E. Jones, T A. Bailey
One of the most important issues in liquid composite molding (LCM) is the complete saturation of the preform by the resin to eliminate voids or dry spots in the...
NIST develops Standard Reference Materials for calibration, quality assurance and research into improved measurements. Two fluid standards are being developed...