Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1051 - 1075 of 2521

Superconducting Thin-Film Transformers at Microwave Frequencies

June 1, 1999
Author(s)
A. H. Miklich, J. X. Przybysz, T. J. Smith, Samuel Benz, Todd E. Harvey
… superconducting transformers at frequencies up to 20 GHz. Transformers with turns ratios of 2,3, and 7 were fabricated out of Nb and tested in a liquid-He Dewar. …

Viscoelasticity of Xenon Near the Critical Point

February 1, 1999
Author(s)
Robert F. Berg, Michael R. Moldover, G A. Zimmerli
Using a novel, overdamped, oscillator flown aboard the Space Shuttle, we measured the viscosity of xenon near the liquid-vapor critical point in the frequency range 2 Hz [less than or equal to} f {less than or equal to} 12 Hz. The measured viscosity

The Growth of Iron on Iron Whiskers

January 1, 1994
Author(s)
Joseph A. Stroscio, Daniel T. Pierce
… of the Fe atoms is obtained over the temperature range of 20-250° C from the temperature dependence of the island …

Single-photon Sources and Detectors Dictionary

August 4, 2025
Author(s)
Joshua Bienfang, Thomas Gerrits, Paulina Kuo, Alan Migdall, Sergey Polyakov, Oliver Slattery
The intention of this dictionary is to define relevant terms and metrics used in the characterization of single-photon detectors and sources with the goal to promote better understanding and communication of those metrics across the single-photon

Shrinks When It's Colder

August 1, 2022
Author(s)
Patrick Egan
… cell length is measured by coordinate-measuring machine at 20 ℃. However, the refractometer will operate at the … to scale the accuracy of the dimensional metrology across 20 ℃ to the triple-point of water requires that the thermal …

Establishing an upper bound on contact resistivity of ohmic contacts to n-GaN nanowires

April 1, 2014
Author(s)
Paul T. Blanchard, Kristine A. Bertness, Todd E. Harvey, Norman A. Sanford
… by molecular beam epitaxy. Four-contact structures with 20 nm Ti/200 nm Al contacts were fabricated on individual NWs … resulting upper limits on ρ c ranged from 4.2 × 10 −6 to 7.6 × 10 −6 {Ω} cm 2 , indicating that 20 nm Ti/200 nm Al is a good choice of ohmic contact for …

Chemical Warfare Agent Detection Using MEMS Microsensor Arrays

August 1, 2005
Author(s)
Douglas C. Meier, C J. Taylor, Richard E. Cavicchi, Edward White V, M W. Ellzy, K B. Sumpter, Stephen Semancik
… stability studies carried out for 14 hours in GB exhibit 20% signal variation; similar studies in HD show little … programmed sensing (TPS) over a broad temperature range (20 C to 480 C) enhances analyte selectivity, since the …

Bending Performance of Masonry Walls Strengthened With Near-Surface Mounted FRP Bars.

June 1, 2003
Author(s)
K Bajpai, D Kuthinh
… of 6.5 mm (114 in) diameter glass FRP bars in 185 mm (7.3 in), or less than half a concrete masonry unit length. … out-of-plane bending. Three narrow (2.85 m x 0.40 m x 0.20 m or 112 in x 16 in x 8 in), grouted, concrete masonry … 45% of balanced ratio and four wide (2.85 m x 0.80 m x 0.20 m or 112 in x 32 in x 8 in) beams reinforced to 66% of …
Displaying 1051 - 1075 of 2521
Was this page helpful?