An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Gregory A. Cooksey, Anne L. Plant, Francisco J. Atencia
The lack of simple interfaces for microfluidic devices with a large number of inlets significantly limits production and utilization of these devices. In this
Recent developments in optical microscopy promise to advance optical metrology and imaging to unprecedented levels through theoretical and experimental
An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from
We developed artificial neural network models to simultaneously identify three separate impairments that can degrade optical channels, namely optical signal-to
Dale P. Bentz, Max A. Peltz, Kenneth A. Snyder, Jeffrey M. Davis
Our nation's infrastructure and long term containment of nuclear waste are two critical applications requiring concrete with an increased service life. In this
Dean G. Jarrett, Randolph E. Elmquist, Nien F. Zhang, Alejandra Tonina, M Porfiri, Janice Fernandes, H Schechter, Daniel Izquierdo, C Faverio, Daniel Slomovitz, Dave Inglis, Kai Wendler, Felipe Hernandez-Marquez, B Rodriguez
A set of regional comparisons of dc resistance standards at the nominal values of 1 {Ω}, 1 M {Ω}, and 1 G {Ω} has recently been completed in the Sistema
Joannie W. Chin, Sylvain H. Petit, Amanda L. Forster, Michael A. Riley, Kirk D. Rice
During routine field use of soft body armor, the ballistic panels often become saturated with perspiration. This condition motivates the user to clean and/or
James E. Maslar, Wilbur S. Hurst, Walter J. Bowers Jr., Jay H. Hendricks
Alloy 600 coupons were exposed to air-saturated water at pressures of 15.65 MPa and 25.4 MPa and temperatures ranging from 21 C to 543 C in an optically
With a modulator based 10 GHz optical frequency comb generator at 1.55 mm, we report a 20 GHz repetitive train of optical pulses as short as 450 femtoseconds
James C. Booth, Jordi Mateu, Carlos Collado, Eduard Rocas, Juan M. O'Callaghan, Nathan D. Orloff
This paper describes the procedure to obtain analytical expressions for the spurious signals generated in nonlinear transmission lines with impedance mismatch
A mapping between the CIMsteel Integration Standards (CIS/2) and the Industry Foundation Classes (IFC) product data models for structural steel has been
D. M. Rampulla, N Oncel, E Abelev, Y Yi, Svenja A. Knappe, S Bernasek
Coated atomic resonance cells are used in atomic magnetometers, atomic clocks, and magneto-optical traps. Recent work has shown that there is a significant
M Feinholz, S Flora, M Yarbrough, Keith R. Lykke, Steven W. Brown, B. Carol Johnson, Dennis Clark
The Marine Optical System is a spectrograph-based sensor used in the Marine Optical Buoy for the vicarious calibration of ocean color satellite sensors. It is
Elisa Martinelli, Sara Menghetti, Giancarlo Galli, Antonella Glisenti, Sitaraman Krishnan, Marvin Y. Paik, Christopher K. Ober, Detlet-M Smilgies, Daniel A. Fischer
A series of diblock copolymers prepared from styrenic monomers was synthesized using ATRP. One block was derived from styrene while the second block was
Steve M. Gwynne, Jessica Kratchman, Erica D. Kuligowski, James A. Milke
This paper suggests that the currently assumed linear relationship between exit width and achievable flow is a simplification that may lead to an overly
David F. Plusquellic, Weimin Zhang, Karen M. Siegrist, Susan K. Gregurick
Terahertz (THz) spectra of the crystalline VA class dipeptide nanotubes were calculated at both the harmonic and Vibrational Self-consistent Field (VSCF) level
Acoustic emission (AE) sources in a plate generate dispersive Lamb waves. In this research, pencil lead breaks (PLBs) were made on an edge of a 3.1 mm thick
Foreword. This is the calendar year 2008 edition of a report series summarizing the technology transfer activities and achievements of the Department of
D. K. Singh, J. S. Helton, S. Chu, T. Han, C. Bonnoit, Sung Chang, Hye J. Kang, Jeffrey W. Lynn, Y. S. Lee
We report neutron scattering studies of the spin correlations of the geometrically frustrated py- rochlore Tb 2Mo 2O 7using single crystal samples. Elastic
Health care informatics deals with all the processes or "software" of the health care enterprise: modeling, design, simulation and implementation of health care
Dan B. Dougherty, Jim Wei, William Cullen, Janice Reutt-Robey, Steven W. Robey
Pentacene deposited onto a Ag(111) surface at 300 K is studied using scanning tunneling microscopy at temperatures of 300 K and 50 K. At 300 K, ordered
Calcium phosphate cement (CPC) can be molded to conform to complex bone cavities and set in situ to form bioresorbable hydroxyapatite. The aim of this study was
Justin N. O'Donnell, Gary E. Schumacher, Joseph M. Antonucci, Drago Skrtic
Aims. The objective of this study was to measure the adhesive strength to dentin, work to fracture, and failure modes of three resin composites (with differing
Yi-Lei Zhao, Jason W. Flora, Stephen Garrison, Carlos A. Gonzalez, K. N. Houk, Manuel Marquez
A yellow solid material [PxHy] has been obtained in the reaction of phosphine (PH3) and nitric oxide (NO) at room temperature, and characterized by TGA-MS and