Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1576 - 1600 of 2717

Influence of molecular mass on the modulus of thin polystyrene films

March 21, 2010
Author(s)
Jessica M. Torres, Christopher Stafford, Bryan D. Vogt
In this work, we examine the influence of relative molecular mass (Mn, or the number average molecular mass) of PS on the thickness-dependent moduli using a wrinkling based instability of a stiff film on an elastic substrate. This wrinkling based metrology

Measurement Science Roadmap for Net-Zero Energy Buildings

March 18, 2010
Author(s)
Joan Pellegrino, Arthur H. Fanney, Andrew K. Persily, Piotr A. Domanski, William M. Healy, Steven T. Bushby
Buildings account for nearly a third of the world s energy use today, and this share is expected to rise along with population growth and levels of prosperity. In the United States, residential and commercial buildings consume about 40% of primary energy

Neutron radioscopy: industrial and scientific applications

March 15, 2010
Author(s)
Daniel Hussey, Michael A. Hickner
Neutron imaging has been a unique, precise, measurement tool for water transport in proton exchange membrane fuel cells (PEMFCs), enabling the direct measurement of the water distribution in standard, commercially viable fuel cell hardware. Thus, in the

Water based Polyurethane Graphene Oxide Nanocomposites

March 3, 2010
Author(s)
Coralie Bernard, Tinh Nguyen, Bastien T. Pellegrin, Mat Celina, Alexander J. Shapiro, Deborah Jacobs, Kar T. Tan, Sungjin Park, R. S. Ruoff, Joannie W. Chin
Graphene oxides are potentially a new class of nanomaterial to enhance multifunctional properties of polymers because of their remarkable thermal conductivity, mechanical strength, and more importantly, low cost. The graphene oxides, produced by

Utility Assessment in TRANSTAC: Using a set of complementary methods

February 8, 2010
Author(s)
Michelle P. Steves, Emile L. Morse
This paper describes the methods used during formative utility assessments for speech-to-speech, real-time translation systems intended for tactical use. The systems, while still prototypical, had hardware platforms that could be exercised indoors or

Comparison of Large-Signal-Network-Analyzer Calibrations

February 5, 2010
Author(s)
Dylan F. Williams, Catherine A. Remley, Joe Gering, Grand Aivazian
We develop a procedure and metrics for comparing large-signal-network-analyzer calibrations. The metrics we develop provide a bound on differences between measurements obtained from large-signal-network-analyzer calibrations, as well as more specific

Characterization of SiGe Films for use as a National Institute of Standards and Technology (NIST) Microanalysis Reference material (RM 8905)

February 1, 2010
Author(s)
Ryna B. Marinenko, Shirley Turner, David S. Simons, Savelas A. Rabb, Rolf L. Zeisler, Lee L. Yu, Dale E. Newbury, Rick L. Paul, Nicholas W. Ritchie, Stefan D. Leigh, Michael R. Winchester, Lee J. Richter, Douglas C. Meier, Keana C. Scott, D Klinedinst, John A. Small
Bulk SiGe wafers cut from single-crystal boules and two SiGe thick films (4 m and 5 m thick) on Si wafers were evaluated with the electron probe microanalyzer for the extent of heterogeneity and composition for use as reference materials needed by the

NIST HB 105-4, Specifications and Tolerances for Reference Standards and Field Standard Weights and Measures 4. Specifications and Tolerances for Liquefied Petroleum Gas and Anhydrous Ammonia Pressurized Volumetic Field Standards

February 1, 2010
Author(s)
Georgia L. Harris, L.F. Eason
These specifications and tolerances are recommended as minimum requirements for standards used by state and local weights and measures officials and others in the regulatory verification of meters used in quantity determination of pressurized liquid

Three steps towards metrological traceability for ballistics signature measurements

February 1, 2010
Author(s)
Jun-Feng Song, Theodore V. Vorburger, Robert M. Thompson, Thomas Brian Renegar, Xiaoyu Alan Zheng, Li Ma, James H. Yen, Martin Ols
The National Institute of Standards and Technology (NIST) in collaboration with the Bureau of Alcohol, Tobacco, Firearms, and Explosives (ATF) has developed the Standard Reference Material (SRM) 2460 bullets and 2461 casings. NIST and ATF are proposing to

NIST HB 105-3, Specifications and Tolerances for Reference Standards and Field Standard Weights and Measures, 3. Specifications and Tolerances for Graduated Neck Type Volumetric Field Standards

January 31, 2010
Author(s)
Georgia L. Harris, L.F. Eason
These specifications and tolerances are recommended as minimum requirements for standards used by state and local weights and measures officials and others in the regulatory verification of meters used in quantity determination of liquid commodities. Other

DYNAMIC PERCEPTION WORKSHOP REPORT: Requirements and Standards for Advanced Manufacturing

January 14, 2010
Author(s)
Tsai Hong Hong, Elena R. Messina, Hui-Min Huang, Michael O. Shneier, Roger D. Eastman, Jane Shi, James Wells
The Dynamic Perception workshop was intended to further the development of standardized, reproducible, and portable test methods that can advance the technology of sensors and perception systems for new, flexible robotic and automation applications in

Vibration spectrum of a low-vibration pulse-tube cryostat from 1 Hz to 20 kHz

January 11, 2010
Author(s)
Akobuije D. Chijioke, John R. Lawall
The vibrations of the cold finger of a low-vibration helium pulse-tube cryostat are measured from 1 Hz to 20 kHz using an optical interferometer specially designed to measure small vibrations at high frequencies in the presence of large vibrations at lower

Demonstrating the metrological compatibility of uranium isotope amount ratio measurement results performed by GSMS, TIMS and MC-ICPMS techniques

January 5, 2010
Author(s)
Olivio Pereira de Oliveira, Willy De Bolle, Stefan Richter, Adolfo Alonso, Emmanuel Ponzevera, Christophe Qu?tel, Jorge Eduardo de Souza Sarkis, Roger Wellum, Ruediger Kessel
The metrological compatibility of n(234U)/n(238U), n(235U)/n(238U) and n(236U)/n(238U) isotope amount ratio measurement results performed by gas source mass spectrometry (GSMS), thermal ionisation mass spectrometry (TIMS) and multi-collector inductively
Displaying 1576 - 1600 of 2717
Was this page helpful?