Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 476 - 500 of 2904

Automated Analysis of Organic Particles Using Cluster SIMS

June 1, 2004
Author(s)
John G. Gillen, Cynthia J. Zeissler, Christine M. Mahoney, Abigail P. Lindstrom, Robert A. Fletcher, P Chi, Jennifer R. Verkouteren, David S. Bright, R Lareau, M Boldman
… Cluster primary ion bombardment combined with secondary ion imaging is used in an ion microscope secondary ion mass spectrometer for the … SIMS, explosives, inkjet, particle searching, polyatomic ion

Application of Microcalorimeter Energy Measurement to Biopolymer Mass Spectrometry

March 1, 2001
Author(s)
B. Neuhauser, Gene C. Hilton, John M. Martinis
… microcalorimeter detector. We emphasize the measurement of ion-impact energy as a way to obtain extra information that … measurements are used to discriminate against erroneous ion-strikes, to resolve ambiguities that connot be resolved … ion energy, microcalorimeter, mixture analysis …

Quantitative Depth Profiling of an Alternating Pt/Co Multilayer and a Pt Co Alloy multilayer by SIMS using a Buckminsterfullerene (C60) Source

May 15, 2007
Author(s)
K.J. Kim, David S. Simons, J Greg Gillen
… Buckmins erfullerene ion beam has been applied o he dep h profiling of an al erna … Quan i a ive dep h profiling was performed by secondary ion mass spec rome ry (SIMS) wi h C60 ions using P Co alloy … were used o conver an original dep h profile o a composi ion dep h profile. A severe in erface ar ifac observed in he …

Enhanced Model for Scanning Tunneling Microscope Tip Geometry Measured with Field Ion Microscopy

March 10, 2004
Author(s)
P V. Rao, Carsten P. Jensen, Richard M. Silver
… as conical, spherical, or parabolic. By using a field ion microscope (FIM), the tip shape and size can be measured … characterize SPM tips, detailed shape of the tip, field ion microscopy (FIM), scanning probe microscope, tip character … Tunneling Microscope Tip Geometry Measured with Field Ion Microscopy …

Decoherence-Free Quantum Memory Using Trapped Ions

January 1, 2001
Author(s)
D Kielpinski, V Meyer, M A. Rowe, C A. Sackett, Wayne M. Itano, C Monroe, David J. Wineland
… decoherence-free subspace (DFS) of a pair of trapped 9Be+ ions, we protect the qubit from environment-induced dephasing … arbitrary qubit stored in a single ion to the DFS of two ions. … Decoherence-Free Quantum Memory Using Trapped Ions

Light-Cured Dimethacrylate-Based Resins and Their Composites: Comparative Study of Mechanical Strength, Water Sorption and Ion Release

July 30, 2008
Author(s)
Justin N. O'Donnell, Sarah Langhorst, Michael D. Fow, Joseph M. Antonucci, Drago Skrtic
… flexure strength (BFS), water sorption (WS) and mineral ion release upon immersion in HEPES-buffered saline solution … higher than the BFS of the corresponding ACP composites. Ion release data indicated that a minimum mass fraction of 35 … amorphous calcium phosphate, composites, ion release, mechanical strength, photo-polymerization, water …

Building Blocks for a Scalable Quantum Information Processor Based On Trapped Ions

January 1, 2003
Author(s)
Dietrich G. Leibfried, Murray D. Barrett, A Ben-kish, Joseph W. Britton, J Chiaverini, B. L. DeMarco, Wayne M. Itano, Branislav M. Jelenkovic, John D. Jost, Christopher Langer, D Lucas, V Meyer, Till P. Rosenband, M A. Rowe, T Schaetz, David J. Wineland
… a Scalable Quantum Information Processor Based On Trapped Ions

EUV spectra from N-shell ions of Gd, Dy and W

September 23, 2013
Author(s)
Deirdre Kilbane, John D. Gillaspy, Yuri Ralchenko, Joseph Reader, G. O'Sullivan
… radiation from gadolinium, dysprosium and tungsten ions with an open n=4 shell were performed at the National Institute of Standards and Technology. The ions were produced and confined in an electron beam ion trap … EUV spectra from N-shell ions of Gd, Dy and W …

Enthalpies of Dilution of NdCl 3 (aq) at Temperatures from 297.89 K to 372.08 K and an Extended Pitzer Ion-Interaction Model for the NdCl 3 + H 2 O System

March 1, 2004
Author(s)
C S. Oakes, J A. Rard, Donald G. Archer
… to yield the parameters of an exended form of Pitzer's ion-interaction model valid to high molalities and for the … activity coefficient, enthalpy, heat capacity, ion-interaction, neodymium chloride, phase equilibrium, … from 297.89 K to 372.08 K and an Extended Pitzer Ion-Interaction Model for the NdCl 3 + H 2 O System …

Atomic Physics in Ion Traps

March 1, 1997
Author(s)
C Monroe, John Bollinger
Ion traps allow researchers to control the position and … Atomic Physics in Ion Traps …

Thick Sintered Electrode Lithium-Ion Battery Discharge Simulations: Incorporating Lithiation-Dependent Electronic Conductivity and Lithiation Gradient due to Charge Cycle

April 21, 2021
Author(s)
Daniel S. Hussey, Jacob LaManna, David L. Jacobson, Gary Koenig
… In efforts to increase the energy density of lithium-ion batteries, researchers have attempted to both increase … Thick electrode, Modeling, Discharge Simulation, Lithium-Ion Battery … Thick Sintered Electrode Lithium-Ion Battery Discharge Simulations: Incorporating …

Scalable Quantum Logic Spectroscopy

November 2, 2022
Author(s)
Kaifeng Cui, Jose Valencia, Kevin Boyce, Ethan Clements, David Leibrandt, David Hume
… In quantum logic spectroscopy (QLS), one species of trapped ion is used as a sensor to detect the state of an otherwise inaccessible ion species. This extends precision measurements to a broader … to address the problem of scaling QLS to larger ion numbers. We demonstrate the basic features of this method …

Colloquium: Ionic phenomena in nanoscale pores through 2D materials

June 27, 2019
Author(s)
Subin Sahu, Michael P. Zwolak
Ion transport through channels and nanoscale pores cuts … develop filtration and sensing technologies, encompassing ion exclusion membranes, DNA sequencing, single molecule … We will discuss both the physics and applications of ion transport and sensing in 2D membranes. …

Depth Profiling Using C 60 + SIMS Deposition and Topography Development During Bombardment of Silicon

July 30, 2006
Author(s)
John G. Gillen, J Batteas, Chris A. Michaels, P Chi, John A. Small, Eric S. Windsor, Albert J. Fahey, Jennifer R. Verkouteren, W Kim
… A C60+ primary ion source has been coupled to an ion microscope SIMS instrument to examine sputtering of … also observed on silicon substrates after high primary ion dose C60+ bombardment. … cluster bombardment, depth profiling, fullerene, ion source, secondary ion mass spectrometry …

Energies and E1, M1, E2, and M2 transition rates for states of the 2s22p4, 2s2p5, and 2p6configurations in oxygen-like ions between F II and Kr XXIX.

September 24, 2013
Author(s)
P. Rynkun, P. Jonsson, G. Gaigalas, Charlotte F. Fischer
… 2s2p5, and 2p6 configurations in all oxygen-like ions between F II and Kr XXIX. Valence, core-valence, and … O-like ions, energies, lifetimes, transition rates, weighted … of the 2s22p4, 2s2p5, and 2p6configurations in oxygen-like ions between F II and Kr XXIX. …

Measurement of the Kr XVIII 3d 2D5/2 lifetime in a Unitary Penning Trap

April 24, 2014
Author(s)
Nicholas D. Guise, Joseph Tan, Samuel Brewer, Charlotte F. Fischer, P. Jonsson
… trapping volume. Kr17+ ions produced in an electron beam ion trap (EBIT) are extracted and captured in this unitary … that is about a factor of 102 lower than in the EBIT ion source. The 637 nm photons emitted by the captured Kr … Ion trapping, Atomic spectroscopy, Atomic Physics …

Fragmentation of Leucine Enkephalin as a Function of Laser Fluence in a MALDI TOF-TOF

April 2, 2007
Author(s)
Jennifer M. Campbell, Stephen Stein, Paul S. Blank, Jonathan Epstein, Marvin L. Vestal, Alfred L. Yergey
… The effects of laser fluence on ion formation in MALDI was studied using a tandem TOF mass … followed over laser fluence ranging from the threshold of ion formation to the maximum available, i.e., approximately … data suggest the presence of two distinct environments for ion formation. One is associated with molecular desorption at …
Displaying 476 - 500 of 2904
Was this page helpful?