Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1076 - 1100 of 2521

Solidification of Ni-Re Peritectic Alloys

February 4, 2019
Author(s)
William J. Boettinger, Dale E. Newbury, Nicholas W. Ritchie, Maureen E. Williams, Ursula R. Kattner, Eric Lass, Kil-Won Moon, Michael B. Katz
… DTA and as-cast Ni-Re alloys with compositions between 0.20 and 0.44 mass fraction Re provide information to resolve …

Octave-spanning dual frequency comb spectroscopy in the molecular fingerprint region

June 4, 2018
Author(s)
Henry R. Timmers, Abijith S. Kowligy, Alexander J. Lind, Flavio Caldas da Cruz, Nima Nader, Myles C. Silfies, Thomas K. Allison, Gabriel G. Ycas, Peter G. Schunemann, Scott B. Papp, Scott A. Diddams
… in the molecular fingerprint spectral region (6.5-20 $\mu$m) yields critical information on material structure …

A Faraday-shielded, DC Stark-free optical lattice clock

May 2, 2018
Author(s)
Kyle P. Beloy, Xiaogang Zhang, William F. McGrew, Nathan M. Hinkley, Tai H. Yoon, Daniele Nicolodi, Robert J. Fasano, Stefan A. Schaeffer, Roger C. Brown, Andrew D. Ludlow
… place a constraint on the DC Stark shift at the 10 -20 level, in units of the clock frequency. Moreover, we …

Small Particle Driven Chain Disentanglements in Polymer Nanocomposites

April 5, 2017
Author(s)
Erkan NMN Senses, Siyam M. Ansar, Christopher L. Kitchens, Yimin NMN Mao, Suresh Narayanan, Bharath NMN Natarajan, Antonio Faraone
… size ({approximately equal}5 nm), at a volume fraction of 20%. The tube diameter remains unchanged in composite with …

Public Safety Analytics R&D Roadmap

April 19, 2016
Author(s)
Tracy A. McElvaney, Ryan Felts, Marc Leh
… is in a period of great transition. Over the next 20 years, technology advancements will increase accessibility …

Magnetoencephalography with a chip-scale atomic magnetometer

April 17, 2012
Author(s)
Svenja A. Knappe, Tillman H. Sander, Jan Preusser, Rahul R. Mhaskar, John E. Kitching, Lutz Trahms
We report on the measurement of somatosensory-evoked and spontaneous magnetoencephalography signals with a chip-scale atomic magnetometer. This uncooled, fiber-coupled sensor has a sensitive volume of 0.58 mm 3 inside a sensor head of volume 1 cm 3. When

A circular dielectric grating for vertical extraction of single quantum dot emission

July 25, 2011
Author(s)
Marcelo I. Davanco, Matthew T. Rakher, Dieter Schuh, Antonio Badolato, Kartik A. Srinivasan
… e±ciency > 80% with a high numerical aperture (NA=0.7) optic, and with 12 times Purcell radiative rate … % photon collection effciency with a NA=0.42 objective, a 20 times improvement over quantum dots in unpatterned GaAs. A …

A Compact Variable-Temperature Broadband Series-Resistor Calibration

January 1, 2011
Author(s)
Nathan D. Orloff, Jordi Mateu, Arkadiusz C. Lewandowski, Eduard Rocas, Joshua P. King, Dazhen Gu, Juan C. Collado Gomez, Ichiro Takeuchi, Xiaoli Lu, James C. Booth
… where the model parameters are extracted at 300 K down to 20 K to determine their temperature dependence. The resultant …

Spectroradiometric Characterization of the NIST Pulsed Solar Simulator

August 20, 2009
Author(s)
Howard W. Yoon, Brian P. Dougherty, Vladimir Khromchenko
The spectroradiometric characterization of the NIST indoor pulsed solar simulator is described. The solar simulator has a flash duration of 36.4 ms and is designed for solar panels having a maximum size of 2.0 m by 1.6 m. As per industry standards, the

High-performance, vibration-immune, fiber-laser frequency comb

March 1, 2009
Author(s)
Esther Baumann, Fabrizio R. Giorgetta, Jeffrey W. Nicholson, William C. Swann, Ian R. Coddington, Nathan R. Newbury
… between the comb and cw reference laser of −94 dBc/Hz from 20 Hz to 200 kHz and an integrated in-loop phase noise of 32 …

High Contrast Scanning Nano-Raman Spectroscopy of Silicon

June 15, 2007
Author(s)
N Lee, R Hartschuh, D Mehtani, A Kisliuk, M D. Foster, Alexei Sokolov, J F. Maguire, Martin L. Green
We have demonstrated that scanning nano-Raman spectroscopy (SNRS), generally known as tip enhanced Raman spectroscopy (TERS), with side illumination optics can be effectively used for analysis of silicon based structures at the nanoscale. Even though the

Observation of the 1 S 0 - 3 P 0 clock transition in 27 Al +

June 1, 2007
Author(s)
Till P. Rosenband, P. O. Schmidt, David Hume, Wayne M. Itano, Tara M. Fortier, Jason Stalnaker, Scott A. Diddams, Jeroen Koelemeij, James C. Bergquist, David J. Wineland
… to measure the lifetime fo the metastable clock state, τ = 20.6+/-1.4 s, the ground state 1 S 0 g factor, gs = …
Displaying 1076 - 1100 of 2521
Was this page helpful?