Test Description For details of the test structure, materials, fire source, and instrumentation, see the full NIST report: NIST Technical Note 1455-1 , February 2008 Revision, Full Report (3/3/2008) Performance of Home Smoke Alarms Analysis of the Response of Several Available Technologies in Residential Fire Settings.
Temperature Temperature. Bedroom 1. 25 mm from ceiling
Temperature. Bedroom 1. 300 mm from ceiling
Temperature. Bedroom 1. 610 mm from ceiling
Temperature. Bedroom 1. 900 mm from ceiling
Temperature. Bedroom 1. 1220 mm from ceiling
Temperature. Hallway. 25 mm from ceiling
Temperature. Hallway. 300 mm from ceiling
Temperature. Hallway. 610 mm from ceiling
Temperature. Hallway. 900 mm from ceiling
Temperature. Hallway. 1220 mm from ceiling
Temperature. Bedroom 3. 25 mm from ceiling
Temperature. Bedroom 3. 300 mm from ceiling
Temperature. Bedroom 3. 610 mm from ceiling
Temperature. Bedroom 3. 900 mm from ceiling
Temperature. Bedroom 3. 1220 mm from ceiling
Temperature. Foyer. 25 mm from ceiling
Temperature. Foyer. 300 mm from ceiling
Temperature. Foyer. 610 mm from ceiling
Temperature. Foyer. 900 mm from ceiling
Temperature. Foyer. 1220 mm from ceiling
Temperature. Den. 25 mm from ceiling
Temperature. Den. 300 mm from ceiling
Temperature. Den. 610 mm from ceiling
Temperature. Den. 900 mm from ceiling
Temperature. Den. 1220 mm from ceiling
Temperature. Living Room. 25 mm from ceiling
Temperature. Living Room. 300 mm from ceiling
Temperature. Living Room. 610 mm from ceiling
Temperature. Living Room. 900 mm from ceiling
Temperature. Living Room. 1220 mm from ceiling
Temperature. Kitchen. 25 mm from ceiling
Temperature. Kitchen. 300 mm from ceiling
Temperature. Kitchen. 610 mm from ceiling
Temperature. Kitchen. 900 mm from ceiling
Temperature. Kitchen. 1220 mm from ceiling
Temperature. Bedroom 3. Above Fire
Temperature. Living Room. Above Fire
Temperature. Kitchen. Above Fire
Temperature at data acquisition system
Smoke Obscuration Smoke Obscuration. Bedroom 1. 25 mm from ceiling
Smoke Obscuration. Bedroom 1. 300 mm from ceiling
Smoke Obscuration. Hallway. 25 mm from ceiling
Smoke Obscuration. Hallway. 300 mm from ceiling
Smoke Obscuration. Foyer. 25 mm from ceiling
Smoke Obscuration. Foyer. 300 mm from ceiling
Smoke Obscuration. Foyer. 300 mm from ceiling #2
Smoke Obscuration. Den. 25 mm from ceiling
Smoke Obscuration. Den. 300 mm from ceiling
CO Concentration Carbon Monoxide concentration. Bedroom 1. Data
CO2 Concentration Carbon Dioxide concentration. Bedroom 1. Data
O2 Concentration Oxygen concentration. Bedroom 1. Data
CO Concentration Carbon Monoxide concentration. Foyer. Data
CO2 Concentration Carbon Dioxide concentration. Foyer. Data
O2 Concentration Oxygen concentration. Foyer. Data
Smoke Alarm Carbon Monoxide Alarm 2. Bedroom 1
Ionization Smoke Alarm 3. Bedroom 1
Photoelectric Smoke Alarm 1. Bedroom 1
Carbon Monoxide Alarm 3. Bedroom 1
Photoelectric Smoke Alarm 1. Bedroom 1
Ionization Smoke Alarm 4. Bedroom 1
Carbon Monoxide Alarm 1. Bedroom 1
Carbon Monoxide Alarm 2. Foyer
Ionization Smoke Alarm 3. Foyer
Photoelectric Smoke Alarm 1. Foyer
Carbon Monoxide Alarm 3. Foyer
Photoelectric Smoke Alarm 3. Foyer
Ionization Smoke Alarm 3. Foyer
Carbon Monoxide Alarm 1. Foyer
Carbon Monoxide Alarm 2. Den
Ionization Smoke Alarm 3. Den
Photoelectric Smoke Alarm 1. Den
Carbon Monoxide Alarm 3. Den
Photoelectric Smoke Alarm 3. Den
Ionization Smoke Alarm 3. Den
Carbon Monoxide Alarm 1. Den
Carbon Monoxide Alarm 2. Hallway
Ionization Smoke Alarm 3. Hallway
Photoelectric Smoke Alarm 1. Hallway
Carbon Monoxide Alarm 3. Hallway
Photoelectric Smoke Alarm 3. Hallway
Ionization Smoke Alarm 3. Hallway
Carbon Monoxide Alarm 1. Hallway
Aspirated Smoke Alarm 1. Bedroom 1
Aspirated Smoke Alarm 1. Foyer
Aspirated Smoke Alarm 1. Den
Ionization Smoke Alarm 1. Bedroom 1
Ionization Smoke Alarm 1. Foyer
Ionization Smoke Alarm 1. Den