August 1, 2017
Author(s)
Arno D. Laesecke, Scott Bair
Viscosity measurements were performed with a falling cylinder viscometer on difluoromethane (R32) and the refrigerant blend R410A (R32+R125 with 50 % by mass) at the temperatures 313.15 K, 348.15 K, and 393.15 K with pressures to 350 MPa. The measurement