Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Galen O'Neil (Fed)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 26 - 50 of 61

Optimization of Time-and Code-Division-Multiplexed Readout for Athena X-IFU

March 18, 2019
Author(s)
William B. Doriese, Simon R. Bandler, Saptarshi Chaudhuri, Carl S. Dawson, Edward V. Denison, Shannon M. Duff, Malcolm S. Durkin, C. T. FitzGerald, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Kent D. Irwin, Young I. Joe, Kelsey M. Morgan, Galen C. O'Neil, Christine G. Pappas, Carl D. Reintsema, David A. Rudman, Stephen J. Smith, Robert W. Stevens, Daniel S. Swetz, Paul Szypryt, Joel N. Ullom, Leila R. Vale, Joel C. Weber, B. A. Young
Readout of a large, spacecraft-based array of superconducting transition-edge sensors (TESs) requires careful management of the layout area and power dissipation of the cryogenic-circuit components. We present three optimizations of our time- (TDM) and

High-Throughput, DC-Parametric Evaluation of Flux-Activated-Switch-Based TDM and CDM SQUID Multiplexers

March 12, 2019
Author(s)
Carl D. Reintsema, Douglas A. Bennett, Edward V. Denison, Malcolm S. Durkin, William B. Doriese, Joseph W. Fowler, Johnathon D. Gard, Arpi L. Grigorian, Gene C. Hilton, Johannes Hubmayr, Galen C. O'Neil, John A. Mates, Kelsey M. Morgan, Daniel R. Schmidt, Robert W. Stevens, Daniel S. Swetz, Leila R. Vale, Joel N. Ullom, Kent D. Irwin, Saptarshi Chaudhuri, Charles J. Titus, Carl S. Dawson
The successful realization and broad deployment of transition edge sensor (TES)-based detector systems has led to significant demand for time-division and code-division superconducting quantum interference device (SQUID) multiplexers time division

A Highly Linear Calibration Metric for TES X-ray Microcalorimeters

August 2, 2018
Author(s)
Christine G. Pappas, Joseph W. Fowler, Douglas A. Bennett, William B. Doriese, Young I. Joe, Kelsey M. Morgan, Galen C. O'Neil, Joel N. Ullom, Daniel S. Swetz
Transition-edge sensor X-ray microcalorimeters are usually calibrated empirically, as the most widely-used calibration metric, optimal filtered pulse height (OFPH), in general has an unknown dependance on photon energy, E γ. Because the calibration

Approaches to the Optimal Nonlinear Analysis of Microcalorimeter Pulses

March 8, 2018
Author(s)
Joseph W. Fowler, Christine G. Pappas, Bradley K. Alpert, William B. Doriese, Galen C. O'Neil, Joel N. Ullom, Daniel S. Swetz
We consider how to analyze microcalorimeter pulses for quantities that are nonlinear in the data, while preserving the signal-to-noise advantages of linear optimal filtering. We apply the approach to compute the electrothermal feedback energy deficit (the

Near- and extended-edge x-ray-absorption fine-structure spectroscopy using ultrafast coherent high-order harmonic supercontinua

March 1, 2018
Author(s)
Dimitar Popmintchev, Benjamin Galloway, Ming-Chang Chen, Franklin Dolar, Christopher Mancuso, Amelia Hankla, Luis Miaja Avila, Galen O'Neil, Guangyu Fan, Skirmantas Alisauskas, Giedrius Andriukaitis, Tadas Balciunas, Oliver M?cke, Audrius Pugzlys, Andrius Baltuska, Henry C. Kapteyn, Tenio Popmintchev, Margaret M. Murnane
Phase matching of the high-order harmonic generation process now makes it possible to produce spatially and temporally coherent ultrafast X-ray beams, with bandwidths spanning more than 12 octaves, from the UV to the keV region. Here we report the first

L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array

December 7, 2017
Author(s)
Daniel S. Swetz, William B. Doriese, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Kelsey M. Morgan, Galen C. O'Neil, Joel N. Ullom
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition- edge-sensor (TES)

A Reassessment of Absolute Energies of X-ray L Lines of Lanthanide Metals

June 28, 2017
Author(s)
Bradley Alpert, W.Bertrand (Randy) Doriese, Gene C. Hilton, Lawrence T. Hudson, Young I. Joe, Kelsey Morgan, Carl D. Reintsema, Dan Schmidt, Daniel Swetz, Csilla Szabo-Foster, Joel Ullom, Joseph Fowler, Galen O'Neil, Douglas Bennett
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors

A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

May 16, 2017
Author(s)
William B. Doriese, Peter Abbamonte, Douglas A. Bennett, Edward V. Denison, Yizhi Fang, Daniel A. Fischer, Colin P. Fitzgerald, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Cherno Jaye, Jessica L. McChesney, Luis Miaja Avila, Kelsey M. Morgan, Young Il Joe, Galen C. O'Neil, Carl D. Reintsema, Fanny Rodolakis, Daniel R. Schmidt, Hideyuki Tatsuno, Jens Uhlig, Leila R. Vale, Joel N. Ullom, Daniel S. Swetz
We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more

Ultrafast time-resolved x-ray absorption spectroscopy of ferrioxalate photolysis with a laser plasma x-ray source and microcalorimeter array

February 17, 2017
Author(s)
Galen C. O'Neil, Joel N. Ullom, Luis Miaja Avila, Young Il Joe, Joseph W. Fowler, Carl D. Reintsema, Daniel S. Swetz, Kevin L. Silverman, Daniel R. Schmidt, Bruce D. Ravel, Gene C. Hilton, William B. Doriese, Bradley K. Alpert, Ralph Jimenez
Using a table-top apparatus based upon a laser plasma x-ray source and an array of cryogenic microcalorimeter x-ray detectors, we have measured the transient x-ray absorption spectrum during the ferrioxalate photoreduction reaction. We observe the Fe K

When "Optimal Filtering" Isn't

December 7, 2016
Author(s)
Joseph Fowler, Bradley Alpert, W.Bertrand (Randy) Doriese, James P. Hays-Wehle, Young I. Joe, Kelsey Morgan, Galen O'Neil, Joel Ullom, Dan Schmidt, Daniel Swetz
The so-called ''optimal filter'' analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy

Ultrafast time-resolved hard x-ray emission spectroscopy on a table top

September 27, 2016
Author(s)
Luis Miaja Avila, Galen C. O'Neil, Young Il Joe, Bradley K. Alpert, Niels Damrauer, William B. Doriese, Steven Fatur, Joseph W. Fowler, Gene C. Hilton, Ralph Jimenez, Carl D. Reintsema, Daniel R. Schmidt, Kevin L. Silverman, Daniel S. Swetz, Hideyuki Tatsuno, Joel N. Ullom
Chemical reactions driven by light are fundamental to biology and a source of inspiration for engineering materials to perform tasks such as solar energy harvesting and data storage. Observing and understanding photodynamics requires experimental tools

Code-division-multiplexed readout of large arrays of TES microcalorimeters

September 15, 2016
Author(s)
Kelsey M. Morgan, Bradley K. Alpert, Douglas A. Bennett, William B. Doriese, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Kent D. Irwin, Young Il Joe, Galen C. O'Neil, Carl D. Reintsema, Edward V. Denison, Daniel R. Schmidt, Joel N. Ullom, Daniel S. Swetz
Code-division multiplexing (CDM) offers a path to reading out large arrays of transition edge sensor (TES) X-ray micro-calorimeters with excellent energy and timing resolution. We demonstrate the readout of X-ray TESs with a 32-channel flux-summed code

Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam Environment

January 19, 2016
Author(s)
Hideyuki Tatsuno, William B. Doriese, Douglas A. Bennett, Catalina Curceanu, Joseph W. Fowler, Johnathon D. Gard, Fredrick P. Gustafsson, Tadashi Hashimoto, Ryugo S. Hayano, James P. Hays-Wehle, Gene C. Hilton, Mihail Iliescu, Shigeru Ishimoto, Kenta Itahashi, Masashiko Iwasaki, Keisuke Kuwabara, Yue Ma, Johann Marton, Hirofumi Noda, Galen C. O'Neil, Shinji Okada, Haruhiko Outa, Carl D. Reintsema, Masaharu Sato, Daniel R. Schmidt, Hexi Shi, Ken Suzuki, Takatoshi Suzuki, Jens Uhlig, Joel N. Ullom, Eberhard Widmann, Shinya Yamada, Johann Zmeskal, Daniel S. Swetz
A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV

Developments in time-division multiplexing of X-ray transition-edge sensors.

December 8, 2015
Author(s)
William B. Doriese, Kelsey M. Morgan, Douglas A. Bennett, Edward V. Denison, Colin P. Fitzgerald, Joseph W. Fowler, Johnathon D. Gard, James P. Hays-Wehle, Gene C. Hilton, Kent D. Irwin, Young Il Joe, John A. Mates, Galen C. O'Neil, Carl D. Reintsema, Nigel O. Robbins, Daniel R. Schmidt, Daniel S. Swetz, Hideyuki Tatsuno, Joel N. Ullom, Leila R. Vale
Time-division multiplexing (TDM) is a mature scheme for the readout of transition-edge sensors. Variants of TDM, which is based on superconducting-quantum-interference-device (SQUID) current amplifiers, have to date been field-deployed in several

Observation of Iron Spin-States using Tabletop X-ray Emission Spectroscopy and Microcalorimeter Sensors

December 2, 2015
Author(s)
Young Il Joe, Galen C. O'Neil, Luis Miaja Avila, Joseph W. Fowler, Kevin L. Silverman, Daniel S. Swetz, Joel N. Ullom, Ralph Jimenez
X-ray emission spectroscopy (XES) is a powerful probe of the electronic and chemical state of elemental species embedded within more complex compounds. X-ray sensors that combine high resolving power and high collecting efficiency are desirable for photon

The Practice of Pulse Processing

November 12, 2015
Author(s)
Joseph W. Fowler, Bradley K. Alpert, William B. Doriese, Young Il Joe, Galen C. O'Neil, Joel N. Ullom, Daniel S. Swetz
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important systematic errors

Microcalorimeter Spectroscopy at High Pulse Rates: a Multi-Pulse Fitting Technique

August 24, 2015
Author(s)
Joseph W. Fowler, Bradley K. Alpert, William B. Doriese, Young Il Joe, Galen C. O'Neil, Cherno Jaye, Joel N. Ullom, Daniel A. Fischer, Daniel S. Swetz
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each sensor must be

Macroscopic Subkelvin Refrigerator Employing Superconducting Tunnel Junctions

August 10, 2015
Author(s)
Xiaohang NMN Zhang, Peter J. Lowell, Brandon L. Wilson, Galen C. O'Neil, Joel N. Ullom
In this paper, we demonstrate a general-purpose macroscopic refrigerator based on the transport of hot electrons through superconducting tunnel junctions. Our refrigerator is intended to provide access to temperatures below those accessible using pumped

High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential

May 1, 2015
Author(s)
W.Bertrand (Randy) Doriese, Joseph Fowler, Daniel Swetz, Cherno Jaye, Daniel A. Fischer, Carl D. Reintsema, Douglas Bennett, Leila R. Vale, Gene C. Hilton, Dan Schmidt, Joel Ullom, Jens Uhlig, Ujjwal Mandal, Galen O'Neil, Luis Miaja Avila, Young I. Joe, wilfrid fullagar, Fredrick P. Gustafsson, Dharma Kurunthu, Villy Sundstrom
X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low

Sub-100 mK cooling using normal-metal?insulator?superconductor tunnel junctions

December 15, 2013
Author(s)
Peter J. Lowell, Galen C. O'Neil, Jason M. Underwood, Xiaohang NMN Zhang, Joel N. Ullom
Normal-metal∖insulator∖superconductor (NIS) junctions can be used as solid-state refrigerators since the hottest electrons preferentially tunnel from the normal metal into the superconductor. In this paper, we present NIS junctions optimized to cool

Macroscale refrigeration by nanoscale electron transport

February 26, 2013
Author(s)
Peter J. Lowell, Galen C. O'Neil, Jason M. Underwood, Joel N. Ullom
Nano- and Micro- Electromechanical devices (NEMS & MEMS) have become ubiquitous; examples include automobile accelerometers, inkjet printer heads, infrared viewers, and mirrors for image manipulation and projection. Applications fall broadly in the

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

September 28, 2012
Author(s)
Douglas A. Bennett, Robert D. Horansky, Daniel R. Schmidt, Andrew Hoover, Ryan Winkler, Bradley K. Alpert, James A. Beall, William B. Doriese, Joseph W. Fowler, Gene C. Hilton, Kent D. Irwin, Nathan J. Hoteling, Vincent Y. Kotsubo, John A. Mates, Galen C. O'Neil, Michael W. Rabin, Carl D. Reintsema, Francis J. Schima, Daniel S. Swetz, Leila R. Vale, Joel N. Ullom
Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gammaray microcalorimeters, based on transition-edge sensors (TESs)