Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 28901 - 28925 of 73830

A Method for Fabricating Conductometric Gas Sensors of Metal Oxide Nanotubes Formed in Porous Aluminum Oxide Membranes

February 2, 2009
Author(s)
Reit Artzi-Gerlitz, Kurt D. Benkstein, David L. Lahr, Joshua L. Hertz, Christopher B. Montgomery, John E. Bonevich, Stephen Semancik, Michael J. Tarlov
We describe a general, simple strategy for fabricating conductometric gas sensors from metal oxide nanotubes formed in nanoporous aluminum oxide membranes. In this approach, the aluminum oxide membrane serves as both a template for growth of the sensing

Coherent measurements with fiber-laser frequency combs

February 2, 2009
Author(s)
Nathan R. Newbury, Ian R. Coddington, Tasshi Dennis, William C. Swann, Paul A. Williams
The coherent and broad spectral output of fiber-laser frequency combs can be exploited for a variety of high-resolution measurements outside of conventional frequency metrology. We will discuss recent measurements in spectroscopy, ranging, and

Low noise frequency comb based on an all-fiber polarization-maintaining figure-8 laser

February 2, 2009
Author(s)
Esther Baumann, Fabrizio R. Giorgetta, Jeffrey W. Nicholson, William C. Swann, Ian R. Coddington, Nathan R. Newbury
We present a frequency comb based on an all-fiber polarization-maintaining figure-8 laser. It is locked to an optical reference through an intracavity high bandwidth electro-optical modulator and has a flat phase noise of -78 dBc/Hz.

Prolonging qubit coherence: dynamic decoupling schemes studied in a Penning ion trap

February 2, 2009
Author(s)
Hermann Uys, Michael J. Biercuk, Aaron Vandevender, N. Shiga, Wayne M. Itano, John J. Bollinger
We present a study of dynamical decoupling schemes for the suppression of phase erros due to various noise environments using ions in a Penning ion trap as a model ensemble of qubits. By injecting frequency noise we demonstrate that in an Ohmic noise

Radiative Beta Decay of the Free Neutron

February 2, 2009
Author(s)
R L. Cooper, T E. Chupp, Maynard S. Dewey, Thomas R. Gentile, Hans Pieter Mumm, Jeffrey S. Nico, Alan Keith Thompson, B M. Fisher, I Kremsky, F E. Wietfeldt, E J. Beise, H Breuer, K G. Kiriluk, J Bryne, Kevin Coakley, Changbo Fu
The theory of quantum electrodynamics predicts that the beta decay of the neutron into a proton, electron, and antineutrino is accompanied by a continuous spectrum of emitted photons described as inner bremsstrahlung. While this phenomenon has been

Statistical analysis of a round-robin measurement survey of two candidate materials for a Seebeck coefficient Standard Reference Material

February 2, 2009
Author(s)
John Lu, Nathan Lowhorn, Winnie Wong-Ng, Weiping Zhang, Evan L. Thomas, Makoto Otani, Martin L. Green, Thanh N. Tran, Chris Caylor, Neil Dilley, Adams Downey, B Edwards, Norbert Elsner, S Ghamaty, Timothy Hogan, Qing Jie, Qiang Li, Joshua B. Martin, George S. Nolas, H Obara, Jeffrey Sharp, Rama Venkatasubramanian, Rhonda Willigan, Jihui Yang, Terry Tritt
In an effort to develop a Standard Reference Material (SRM ) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials undoped Bi2Te3 and constantan (55% Cu and 45% Ni alloy). Measurements were performed in two

Comparison of national air kerma standards for ISO 4037 narrow spectrum series in the range 30 kV to 300 kV.

February 1, 2009
Author(s)
C M. O'Brien, L. Buermann, P. Butler, I. Csete, F. Gabris, A. Hakanen, J. -. Lee, M. Palmer, N. Saito, W. deViries
For the first time results are presented of an indirect comparison of ten national standards for air kerma for ten radiation qualities of the ISO 4037 narrow spectrum series in the range of 30 kV to 300 kV. Nine of the ten participants maintain primary air

Fish-Related Standard Reference Materials

February 1, 2009
Author(s)
Michele M. Schantz, Steven J. Christopher, William C. Davis, Russell D. Day, Jennifer M. Lynch, John R. Kucklick, Stephen E. Long, Elizabeth A. Mackey, Barbara J. Porter, Dianne L. Poster, Katherine E. Sharpless, Gregory C. Turk, Stephen A. Wise
The National Institute of Standards and Technology (NIST) has developed four Standard Reference Materials (SRMs) related to the monitoring of contaminants in fish and marine mammals: SRM 1588b Organics in Cod Liver Oil, SRM 1945 Organics in Whale Blubber

HBAR-Based 3.6GHz Oscillator with Low Power Consumption and Low Phase Noise

February 1, 2009
Author(s)
Hongyu Yu, Chuang-yuan Lee, Wei Pang, Hao Zhang, Alan Brannon, John E. Kitching, Eun Sok Kim
We have designed and built two oscillators, based on High-overtone Bulk Acoustic Resonators (HBAR) for application in Chip-Scale Atomic Clocks (CSAC). The measured phase noise of the 3.6-GHz oscillator is -67 dBc/Hz at 300 Hz offset and ?102 dBc/Hz at 10

ASME International Steam Tables for Industrial Use, Second Edition

January 31, 2009
Author(s)
William T. Parry, J Bellows, J.S. Gallagher, Allan H. Harvey
This book provides printed documentation, tables, and charts for the international standards for water and steam properties for industrial use as adopted by the International Association for the Properties of Water and Steam (IAPWS). This Second Edition

NIST-NRC Comparison of Total Immersion Liquid-in-Glass Thermometers

January 31, 2009
Author(s)
Ken D. Hill, D. J. Gee, Christina D. Cross, Gregory F. Strouse
The use of liquid-in-glass thermometers is described in many documentary standards in the fields of environmental testing, material testing, and material transfer. Many national metrology institutes, including the National Institute of Standards and

ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers

January 30, 2009
Author(s)
Balasubramanian Muralikrishnan, Daniel S. Sawyer, Christopher J. Blackburn, Steven D. Phillips, Bruce R. Borchardt, William T. Estler
Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings), and possibly in the calculated lengths of
Displaying 28901 - 28925 of 73830
Was this page helpful?