Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 451 - 475 of 569

Air-Stable Cu(I) Metal-Organic Framework for Hydrogen Storage

September 1, 2023
Author(s)
Debabrata Sengupta, Patrick Melix, Saptasree Bose, Joshua Duncan, Xingjie Wang, Mohammad Mian, Kent Kirlikovali, Faramarz Joodaki, Timur Islamoglu, Taner N. Yildirim, Randall Snurr, Omar Farha
… one of the initial highest isosteric heats of adsorption (32 kJ/mol) with good hydrogen storage capability under …

Ozone Generation from a Germicidal Ultraviolet Lamp with Peak Emission at 222 nm

July 21, 2023
Author(s)
Michael F. Link, Andrew Shore, Behrang Hamadani, Dustin Poppendieck
… actinometry using tetrachloroethylene (actinometry) and (2) geometric projection of the irradiance field from radial … (irradiance). Using the estimated lamp fluence rates of 2.2 µW cm-2 (actinometry) and 3.2 µW cm-2 (irradiance) we …

Electron Paramagnetic Resonance Study of Carbonated Hydroxyapatite Synthesized through Calcium Phosphate Cements

August 5, 2022
Author(s)
Alline F. Myers, Shozo Takagi, Stanislav Frukhtbeyn, Laurence Chow, Veronika Szalai, Lonnie Cumberland, Ileana Pazos, Eaman Karim
Ionizing radiation-induced paramagnetic defects in calcified tissues like tooth enamel are indicators of irradiation dose. Hydroxyapatite (HA), the principal constituent in these materials, incorporates a variety of anions (CO32, F, Cl, SiO44 ) and

Recommended Dose Calculation Formalisms and Consensus Dosimetry Parameters for Intravascular Brachytherapy Dosimetry: An Update of the 1999 AAPM Task Group 60 Report

October 12, 2021
Author(s)
Sou-Tung Chiu-Tsao, Dennis Schaart, Christopher G. Soares, Ravinder Nath
Since the publication of AAPM Task Group 60 report in 1999, a considerable amount of dosimetry data for the three coronary brachytherapy systems in use in the United States has been reported. A subgroup of the AAPM working group on Unconventional

Bottom-Up Gold Filling in New Geometries and Yet Higher Aspect Ratio Gratings for Hard X-Ray Interferometry

August 24, 2021
Author(s)
Daniel Josell, Thomas P. Moffat, Carlos R. Beauchamp
… is examined in several near-neutral x mol∙L-1 Na3Au(SO3)2 + 0.64 mol∙L-1 Na2SO3 electrolytes (x = [0.08, 0.16, 0.32]) containing ≈ 50 mol∙L-1 Bi3+ additive. The electrolytes … used in earlier work, although the upper bound on Au(SO3)2 concentration is twofold greater than previously described. …

A gas pressure scale based on primary standard piston gauges

December 6, 2010
Author(s)
Douglas A. Olson, Robert G. Driver, Walter J. Bowers Jr.
… to determine their effective area and expanded (k=2) uncertainty. Two piston gauges operating to 7 MPa were … achieved by the primary standards range from 3.0×10-6 to 3.2×10-6. The relative standard uncertainty of the secondary standards is as low as 4.2×10-6 at 300 kPa. The effective areas and uncertainties were …

Analysis of High-Resolution Infrared and N 1 CARS Spectra of 34 S 18 O 3

October 16, 2008
Author(s)
Tony Masiello, J Barber, E T. Chrysostom, J Nibler, A G. Maki, A Weber, Thomas A. Blake, R L. Sams
… in 34 S 18 O 3 due to the close proximity of the Ņ 2 and Ņ 4 fundamental vibrations, whose wave number values … are two standard deviations. Hot band transitions from Ņ 2 , Ņ 4 levels give access to infrared inactive Ņ 2 , Ņ 4 … of 141.7340(1) and 141.7347(7) pm reported earlier for 32 S 16 O 3 and 34 S 16 O 3 . …

Internet Protocol Version 6 (IPv6)

May 30, 2008
Author(s)
Sheila E. Frankel, David Green
… Recognizing that the 32-bit addresses used by the current version of the Internet …
Displaying 451 - 475 of 569
Was this page helpful?