Legendre Fit to the Reflection Coefficient of a Radiating Rectangular Waveguide Aperture

August 1, 2012
Author(s)
Dylan F. Williams, Mohammad T. Ghasr, Bradley K. Alpert, Zhongxiang Shen, Alexander Arsenovic, Robert M. Weikle, Reza Zoughi
We accurately calculate the reflection coefficient and normalized admittance of radiating open-ended rectangular waveguides and fit our results with a linear combination of Legendre polynomials. We verify the expression to an accuracy of 0.005 with other

Microscopic Insights into Ion Gel Dynamics using Neutron Spectroscopy

August 1, 2012
Author(s)
Maiko Kofu, Takenori Someya, Soichi Tatsumi, Kazuhide Ueno, Takeshi Ueki, Masayoshi Watanabe, Takuro Matsunaga, Mitsuhiro Shibayama, Victoria Garcia Sakai, Madhu Sudan Tyagi, Osamu Yamamuro
We have investigated the microscopic dynamics of ion gels consisting of a PMMA [poly(methyl methacrylate)] network and EMITSFI [1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl) imide] as the ionic liquid, by means of quasi-elastic neutron

Mid-infrared virtually imaged phased array spectrometer for rapid and broadband trace gas detection

August 1, 2012
Author(s)
Lora L. Nugent-Glandorf, Tyler W. Neely, Florian B. Adler, Adam J. Fleisher, Kevin C. Cossel, Bryce Bjork, Tim P. Dinneen, Chris S. Wood, Jun Ye, Scott A. Diddams
We present and analyze a 2-D imaging spectrometer based on a virtually imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs. A broad bandwidth, MIR laser source centered at ~3.1 υm

Sensing Trace Amounts of Nitro-Aromatic Explosives using Nanowire-Nanocluster Hybrids

August 1, 2012
Author(s)
Geetha G. Aluri, Abhishek Motayed, Albert Davydov, Vladimir P. Oleshko, Kristine A. Bertness, Norman A. Sanford
The threat of terrorism and the need for homeland security calls for advanced technologies to detect the concealed explosives safely and efficiently. We demonstrated highly sensitive and selective detection of traces of nitro-aromatic explosive compounds

Using Viscosity Modifiers to Reduce Effective Diffusivity in Mortars

August 1, 2012
Author(s)
Kenneth A. Snyder, Dale P. Bentz, Jeffrey M. Davis
Three viscosity modifiers (a commercial shrinkage-reducing admixture, a polypropylene glycol, and cellulose ether) are used to reduce the effective diffusivity of chloride ions through mortars during a one-year exposure. Two delivery mechanisms were

A Literature Review of the Effects of Fire Smoke on Electrical Equipment

July 31, 2012
Author(s)
Richard D. Peacock, Thomas G. Cleary, Paul A. Reneke, Daniel Murphy
A review is presented of the state of the art of smoke production measurement, prediction of smoke impact as part of computer-based fire modeling, and measurement and prediction of the impact of smoke through deposition of soot on and corrosion of

Calibration uncertainty for the NIST PM/AM noise standards

July 31, 2012
Author(s)
Archita Hati, Craig W. Nelson, Neil Ashby, David A. Howe
NIST provides an on-site calibration service of the accuracy of phase modulation (PM) noise, amplitude modulation (AM) noise and noise floor of the measurement systems at a customer's site using one or more portable PM/AM secondary noise standards. In this

Efficient Methods for Interoperability Testing Using Event Sequences

July 31, 2012
Author(s)
David R. Kuhn, James M. Higdon, J .M. Lawrence, Raghu N. Kacker, Yu Lei
Many software testing problems involve sequences of events. The methods described in this paper were motivated by testing needs of mission critical systems that may accept multiple communication or sensor inputs and generate output to several communication

Mobile Application Device Power Usage Measurements

July 31, 2012
Author(s)
Rahul Murmuria, Jeffrey Medsger, Angelos Stavrou, Jeff Voas
Reducing power consumption has become a crucial design tenet for both mobile and other small computing devices that are not constantly connected to a power source. However, unlike devices that have a limited and predefined set of functionality, recent

Topography Measurements and Performance Comparisons between NIST SRM 2460 Standard Bullet Masters and BKA Bullet Replicas

July 31, 2012
Author(s)
Jun-Feng Song, Theodore V. Vorburger, Robert M. Thompson, Susan M. Ballou, Xiaoyu Alan Zheng, Thomas Brian Renegar, Richard M. Silver
Two Standard Reference Material (SRM) 2460 Bullets produced by the National Institute of Standards and Technology (NIST) were used as masters for the fabrication of replica bullets at the Bundeskriminalamt (BKA). The surface topography of the SRM masters

Information Retrieval on the Blogosphere

July 30, 2012
Author(s)
Ian M. Soboroff, Rodrygo Santos, Craig Macdonald, Richard McCreadie, Iadh Ounis
Blogs have recently emerged as a new open, rapidly evolving and reac- tive publishing medium on the Web. Rather than managed by a central entity, the content on the blogosphere—the collection of all blogs on the Web—is produced by millions of independent