Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1826 - 1850 of 2493

Mid-infrared upconversion spectroscopy based on a Yb:fiber frequency laser

October 11, 2011
Author(s)
Scott A. Diddams, Todd Johnson
We present a system for molecular spectroscopy using a mid-infrared broadband frequency comb source with near infrared detection. Difference frequency generation of a Yb:fiber frequency comb produced a mid-infrared (MIR) comb tunable from 2.7 − 4.7 υm

Carbon nanotube arrays for absolute IR and THz radiometry

October 2, 2011
Author(s)
John H. Lehman, Kerry N. Betz, Erich N. Grossman
We have assembled and evaluated a novel electrically calibrated thermopile having an array of 1.5 mm long multiwalled carbon nanotubes as the radiation absorber. We find very low reflectance at the 390 υm laser wavelength and excellent agreement between

The Evolution of Time Measurement, Part 2 - Quartz Clocks

October 1, 2011
Author(s)
Michael A. Lombardi
A historical article about the origins and the development of quartz clocks and oscillators (Part II of a IV-part series). It describes the discovery of piezoelectricity, the development of the first quartz oscillators, how quartz oscillators were

SEM Induced Shrinking of Solid State Nanopores for Single Molecule Detection

September 22, 2011
Author(s)
Anmiv Prahbu, Kevin J. Freedman, Joseph W. Robertson, Zhorro Nikolov, John J. Kasianowicz, MinJun Kim
We have investigated the shrinkage of solid state nanopores by a scanning electron microscope and find the process to be reproducible and dependant beam parameters such as the accelerating voltage and electron flux. The shrinking phenomenon does not

A Laser-Cooled Frequency Standard for GPS

September 20, 2011
Author(s)
Thomas P. Heavner, Stephan E. Barlow, Marc A. Weiss, Neil Ashby, Steven R. Jefferts
NIST is in an initial phase of developing a prototype laser-cooled atomic frequency standard (AFS) for potential use in a future GPS system. The expected fractional frequency stability or Allan deviation, ς y(τ), will be 2x10 -13 at one second, improving

5 MHz Phase Detector With Low Residual Flicker

September 15, 2011
Author(s)
Corey A. Barnes, Archita Hati, Craig W. Nelson, David A. Howe
The measurement of close-to carrier phase modulation (PM) noise of state-of-the-art oscillators is always challenging. Quite often the residual noise of the phase detector used in these measurements is the source of difficulty. In particular at Fourier

Testing Passive UHF Tag Performance Evolution

September 15, 2011
Author(s)
Daniel G. Kuester, David R. Novotny, Jeffrey R. Guerrieri, Zoya Popovic
Trends in tag development since the introduction of the ISO 18000-6C and EPC Global standards are investigated empirically with measurements of power harvesting and backscattering performance from 20 samples of passive tags across 860-960MHz. The

Chip-scale room-temperature atomic magnetometers for biomedical measurements

September 14, 2011
Author(s)
Svenja A. Knappe, Rahul R. Mhaskar, Jan Preusser, John E. Kitching, Lutz Trahms, Tillman H. Sander
We describe a portable 4-channel array of chip-scale atomic magnetometers in a flexible flying-lead configuration. These microfabricated, uncooled sensors with volumes below 1 cm 3 demonstrate sensitivities around 100 fT/Hz 1/2 and bandwidths of several

Single-qubit-gate error below 10 -4 in a trapped ion

September 14, 2011
Author(s)
Kenton R. Brown, Andrew C. Wilson, Yves Colombe, Christian Ospeklaus, Adam M. Meier, Emanuel H. Knill, Dietrich G. Leibfried, David J. Wineland
In theory, quantum computers can solve certain problems much more efficiently than classical computers [1]. This has motivated experimental efforts to construct and verify devices that manipulate quantum bits (qubits) in a variety of physical systems [2]

Frequency-stabilization to 6x10 -16 via spectral-hole burning

September 11, 2011
Author(s)
Michael J. Thorpe, Tara M. Fortier, Matthew S. Kirchner, Till P. Rosenband, Lars Rippe
We demonstrate two-stage laser stabilization based on a combination of Fabry-Pérot and spectral-hole burning techniques. The laser is first pre-stabilized by the Fabry-Pérot cavity to a fractional-frequency stability of ς y(τ) -13. A pattern of spectral

Near-ground-state transport of trapped-ion qubits through a multidimensional array

September 8, 2011
Author(s)
Dietrich G. Leibfried, Rodney B. Blakestad, Christian Ospelkaus, Aaron Vandevender, Janus Wesenberg, Michael J. Biercuk, David J. Wineland
We have demonstrated transport of 9Be+ ions through a 2D Paul-trap X-junction array while maintaining the ions near the motional ground-state of their local potential well. We expand on the first report of the experiment in [1], including a detailed

State Discriminiation Signal Nulling Receivers

September 6, 2011
Author(s)
Francisco E. Becerra Chavez, Jingyun Fan, Gerald Baumgartner, Sergey V. Polyakov, Julius Goldhar, Jonathan Kosloski, Alan L. Migdall
Optimized state-discrimination receiver strategies for nonorthogonal states can improve the capacity of the communication channels operating with error rates below the ones corresponding to conventional receivers. Coherent signal-nulling receivers use a

p-Wave Cold Collisions in an Optical Lattice Clock

September 2, 2011
Author(s)
Nathan D. Lemke, Andrew D. Ludlow, J. von Stecher, Jeffrey A. Sherman, A.M. Rey, Christopher W. Oates
State-of-the-art optical clocks with neutral atoms employ an optical lattice to tightly confine the atoms, enabling high-resolution spectroscopy and the potential for high-accuracy timekeeping. Interrogating many atoms simultaneously facilitates high

An Interlaboratory Stopwatch Comparison in the SIM Region

September 1, 2011
Author(s)
Michael A. Lombardi, Raul Solis, Harold Sanchez, J. Mauricio Lopez-Romero, Francisco Jimenez, Henry Postigo, Daniel Perez, Walter Adad, Victor Masi, Ahmed Ibrahim, Bill Hoger, Ricardo de Carvalho, Jose L. Kronenberg, Gustavo C. Orozco, Theodore Reddock, Leonardo Trigo
Stopwatches and timers are used for an almost unlimited number of applications and are among the most common devices calibrated by metrology laboratories. In large nations, stopwatch calibrations are typically handled by secondary laboratories, such as

Atomic Sensors - A Review

September 1, 2011
Author(s)
John E. Kitching, Svenja A. Knappe, Elizabeth A. Donley
We discuss the basic physics and instrumentation issues related to high performance physical and inertial sensors based on atomic spectroscopy.

SURF III: A flexible Synchrotron Radiation Source for Radiometry and Research

September 1, 2011
Author(s)
Uwe Arp, Charles W. Clark, Lu Deng, Nadir S. Faradzhev, Alex P. Farrell, Mitchell L. Furst, Steven E. Grantham, Edward W. Hagley, Shannon B. Hill, Thomas B. Lucatorto, Ping-Shine Shaw, Charles S. Tarrio, Robert E. Vest
The calculability of synchrotron radiation (SR) makes electron storage rings wonderful light sources for radiometry. The broadband nature of SR allows coverage of the whole spectral region from the x-ray to the far-infrared. Compact low-energy storage

Offset phase locking of noisy diode lasers aided by frequency division

August 31, 2011
Author(s)
Elizabeth A. Donley, Eugene N. Ivanov, Francois-Xavier R. Esnault
For heterodyne phase locking, frequency division of the beat note between two oscillators can improve the reliability of the phase lock and the quality of the phase synchronization. Frequency division can also reduce the size, weight, power, and cost of

Note: Detection of a single cobalt microparticle with a microfabricated atomic magnetometer

August 23, 2011
Author(s)
Svenja A. Knappe, D. Maser, S. Pandey, H. Ring, Micah P. Ledbetter, John E. Kitching, Dimitry Budkerl
Detection of the magnetic signal of a single, 2 {um}m cobalt microparticle using an atomic magnetometer based on a microfabricated vapor cell is presented. These results represent an improvement by a factor of 10 in terms of the detected magnetic moment

Ultralow phase noise microwave generation with an Er:fiber-based optical frequency divider

August 15, 2011
Author(s)
Franklyn J. Quinlan, Tara M. Fortier, Matthew S. Kirchner, Jennifer A. Taylor, Michael J. Thorpe, Nathan D. Lemke, Andrew D. Ludlow, Yanyi Jiang, Christopher W. Oates, Scott A. Diddams
We present an optical frequency divider based on a 200 MHz repetition rate Er:fiber mode-locked laser that, when locked to a stable optical frequency reference, generates microwave signals with absolute phase noise that is equal to or better than cryogenic

A digital time scale at the National Institute of Standards and Technology

August 13, 2011
Author(s)
Stefania Romisch, Steven R. Jefferts, Thomas E. Parker
An integrated time scale has as primary data unit of duration (time interval) defined by atomic standards according to the definition of the SI second. The availability of more than one atomic standard allows for averaging, thereby improving the

Real-Time Generation of the SIM Time Scale (SIMT) from International Clock Comparisons

August 13, 2011
Author(s)
Michael A. Lombardi, Jose M. Lopez, Andrew N. Novick, Francisco Jimenez, Nelida Diaz-Munoz, Eduardo de Carlos Lopez, Jean-Simon Boulanger, Raymond Pelletier, Ricardo de Carvalho, Raul Solis, Harold Sanchez, Liz C. Forero, Junior Gordon, Daniel Perez, Eduardo Bances, Leonardo Trigo, Victor Masi, Henry Postigo, Anthony Questelles, Anselm Gittens, Rodrigo Ramos P.
The Sistema Interamericano de Metrologia (SIM) is one of the world’s five major regional metrology organizations (RMOs). The SIM members are the national metrology institutes (NMIs) located in the 34 nations of the Organization of American States (OAS)
Displaying 1826 - 1850 of 2493
Was this page helpful?