Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 101 - 125 of 850

Intrinsically accurate sensing with an optomechanical accelerometer

May 18, 2022
Author(s)
Benjamin Reschovsky, David Long, Feng Zhou, Yiliang Bao, Richard A. Allen, Jason J. Gorman, Thomas W. LeBrun
We demonstrate a microfabricated optomechanical accelerometer that is capable of percent-level accuracy without external calibration. To achieve this capability, we use a mechanical model of the device behavior that can be characterized by the thermal

Time Programmable Frequency Comb

May 15, 2022
Author(s)
Emily Caldwell, Laura Sinclair, Nathan R. Newbury, Jean-Daniel Deschenes
We demonstrate a programmable optical frequency comb that emits coherent pulses with user-specified time and phase at sub-10 attosecond accuracy while maintaining the underlying referenced stability characteristic of combs.

A self-validated detector for characterization of quantum network components

May 7, 2022
Author(s)
Anouar Rahmouni, Thomas Gerrits, Alan Migdall, Oliver T. Slattery, Ping-Shine Shaw, Joseph P. Rice
We are developing a nearly polarization-independent, low-cost optical trap detector between 1000 nm and 1550 nm for optical power measurements. A NIST-traceable optical power calibration of this trap detector showed a promising result.

White Rabbit-assisted quantum network node synchronization with quantum channel coexistence

May 7, 2022
Author(s)
Thomas Gerrits, Ivan Burenkov, Ya-Shian Li-Baboud, Anouar Rahmouni, DJ Anand, FNU Hala, Oliver T. Slattery, Abdella Battou, Sergey Polyakov
We show that the Ethernet-based time transfer protocol 'White Rabbit' can synchronize two distant quantum-networked nodes to within 4 ps, enabling HOM interference at >90 % visibility using 17.6 ps FWHM single-photons coexisting with White Rabbit.

Measurements of Absolute, SI-traceable Lunar Irradiance with the Airborne LUnar Spectral Irradiance (air-LUSI) Instrument

May 5, 2022
Author(s)
John T. Woodward IV, Kevin Turpie, Thomas Stone, S. Andrew Gadsden, Andrew Newton, Stephen Maxwell, Steven Grantham, Thomas Larason, Steven W. Brown
The Airborne LUnar Spectral Irradiance (Air-LUSI) instrument is designed to make low uncertainty, hyperspectral measurements of the lunar spectral irradiance from an ER-2 aircraft from altitudes above 95 % to 99 % of the atmosphere. Measurements cover the

Photon Efficient Optical Time Transfer

April 24, 2022
Author(s)
Emily Caldwell, Laura Sinclair, William C. Swann, Nathan R. Newbury, Benjamin Stuhl, Jean-Daniel Deschenes
We present a novel frequency comb-based system for optical two-way time-frequency transfer to support very long distance free-space links between clocks. Our Photon-Efficient Agile Comb Optical Clock Synchronization (PEACOCS) system supports sub

Exceptional points in lossy media lead to deep polynomial wave penetration with spatially uniform power loss

April 21, 2022
Author(s)
Alexander Yulaev, Sangsik Kim, Qing Li, Daron Westly, Brian Roxworthy, Kartik Srinivasan, Vladimir Aksyuk
Waves entering a spatially uniform lossy medium typically undergo exponential decay, arising from either the energy loss of the Beer–Lambert–Bouguer transmission law or the evanescent penetration during reflection. Recently, exceptional point singularities

A pyroelectric detector-based method for low uncertainty spectral irradiance and radiance responsivity calibrations in the infrared using tunable lasers

April 4, 2022
Author(s)
Brian Alberding, John Woodward, Ping-Shine Shaw, Leonard Hanssen, Catherine Cooksey, Joseph P. Rice
The standard uncertainty of detector-based radiance and irradiance responsivity calibrations in the short-wave infrared (SWIR) traditionally has been limited to around 1 % or higher by the low spatial uniformity of detectors used to transfer the scale from

Thermal Noise-Limited Laser Stabilization to an 8 mL Volume Fabry-Perot Reference Cavity with Microfabricated Mirrors

March 29, 2022
Author(s)
Charles McLemore, Naijun Jin, Megan Kelleher, James Hendrie, David Mason, Yizhi Luo, Dahyeon Lee, Peter Rakich, Scott Diddams, Franklyn Quinlan
Lasers stabilized to vacuum-gap Fabry-Perot optical reference cavities display extraordinarily low noise and high stability, with linewidths much less than 1 Hz. These lasers can expand into new applications and ubiquitous use with the development of

Models for an Ultraviolet-C Research and Development Consortium

March 25, 2022
Author(s)
Dianne L. Poster, C Cameron Miller, Yaw S. Obeng, John J. Kasianowicz, Michael T. Postek, Norman Horn, Troy Cowan, Richard Martinello
The development of an international, precompetitive, collaborative, ultraviolet (UV) research consortium is discussed as an opportunity to lay the groundwork for a new UV commercial industry and the supply chain to support this industry. History has

Laser-lithographically written micron-wide superconducting nanowire single-photon detectors

March 23, 2022
Author(s)
Maximilian Protte, Varun Verma, Jan Philipp Hopker, Richard Mirin, Sae Woo Nam, Tim Bartley
In this paper, we demonstrate our results on micron-wide tungsten silicide superconducting nanowire single-photon detectors fabricated by laser lithography. Laser-lithographically written devices allow for fast and easy structuring of large areas while

Imaging 3D molecular orientation by orthogonal-pair polarization IR microscopy

February 28, 2022
Author(s)
Shuyu Xu, Chad Snyder, Jeremy Rowlette, Young Lee
Anisotropic molecular alignment occurs ubiquitously and often heterogeneously in three dimensions (3D). However, conventional imaging approaches based on polarization can map only molecular orientation projected onto the 2D polarization plane. Here, an

Predicting solar cell performance from terahertz and microwave spectroscopy

February 26, 2022
Author(s)
Hannes Hempel, Edwin J. Heilweil, Timothy Magnanelli
Mobilities and lifetimes of photogenerated charge carriers are core properties of photovoltaic materials and can both be characterized by contactless terahertz or microwave measurements. Previously reported values for lead-halide perovskites vary by orders

Thermal-light heterodyne spectroscopy with frequency comb calibration

February 18, 2022
Author(s)
Scott Diddams, Connor Fredrick, Franklyn Quinlan, Ryan Terrien, Suvrath Mahadevan, Freja Olsen
Precision laser spectroscopy is key to many developments in atomic and molecular physics and the advancement of related technologies such as atomic clocks and sensors. However, in important spectroscopic scenarios, such as astronomy and remote sensing, the

Femtometer-amplitude imaging of coherent super high frequency vibrations in micromechanical resonators

February 4, 2022
Author(s)
Lei Shao, Vikrant Gokhale, Bo Peng, Peng-Hui Song, Jingjie Cheng, Justin Kuo, Amit Lal, Wen-Ming Zhang, Jason Gorman
The ability to measure femtometer scale vibrations at microwave frequencies is important in applications as diverse as ultracoherent resonators for 5G wireless communications, ultrasensitive detectors for mass and force, and acoustic resonators for quantum

1-GHz mid-infrared frequency comb spanning 3 to 13 mm

January 18, 2022
Author(s)
Nazanin Hoghooghi, Sida XIng, Peter Chang, Daniel Lesko, Alexander Lind, Greg Rieker, Scott Diddams
Mid-infrared (MIR) spectrometers are invaluable tools for molecular fingerprinting and imaging. Among the available spectroscopic approaches, MIR dual-comb absorption spectrometers have the potential to simultaneously combine the high-speed, high spectral

Ultra-broadband Kerr microcomb through soliton spectral translation

December 14, 2021
Author(s)
Gregory Moille, Edgar Perez, Jordan Stone, Ashutosh Rao, Xiyuan Lu, Tahmid Rahman, Yanne Chembo, Kartik Srinivasan
Broad bandwidth and stable microresonator frequency combs are critical for optical atomic clocks, optical frequency synthesis, dual comb spectroscopy, and a host of other applications that require accurate and precise optical frequency measurements in a

Mixture model analysis of Transition Edge Sensor pulse height spectra

December 9, 2021
Author(s)
Kevin J. Coakley, Jolene D. Splett, Thomas Gerrits
To calibrate an optical transition edge sensor, for each pulse of the light source (e.g., pulsed laser), one must determine the ratio of the expected number of photons that deposit energy and the expected number of photons created by the laser. Based on

Semiclassical Theory of Photon Echoes with Application to Pr:YSO

November 4, 2021
Author(s)
Zachary H. Levine
Coherent states are used to prepare a crystal using the Atomic Frequency Comb protocol for quantum memory. Here, semiclassical theory is developed and compared to experimental photon echoes of a coherent pulse.

Generation of perfect vortex beams by dielectric geometric metasurface for visible light

October 31, 2021
Author(s)
Qianwei Zhou, Mingze Liu, Wenqi Zhu, Lu Chen, Yongze Ren, Henri Lezec, Yanqing Lu, Ting Xu, Amit Agrawal
Perfect vortex beam (PVB) is a propagating optical field carrying orbital angular momentum (OAM) with a radial intensity profile that is independent of topological charge. PVB can be generated through the Fourier transform of a Bessel-Gaussian beam, which
Displaying 101 - 125 of 850
Was this page helpful?