Displaying 26 - 50 of 69

Certification of NIST Gas Mixture Standard Reference Materials

February 10, 2022
Author(s)
Christina Cecelski, Kimberly Harris, Cassie Goodman, William A. Kimes, Philip Liu, Walter R. Miller Jr., Jennifer Carney
The Gas Sensing Metrology Group at NIST provides accurate, stable gaseous standards for use in various types of emissions testing and environmental monitoring. The group develops and maintains the highest level of primary gas standards, which provide

Certification of Standard Reference Material(R) 2386 Avocado Powder

October 20, 2021
Author(s)
Melissa M. Phillips, Laura J. Wood, George Caceres, Grace Hahm, Karen E. Murphy, Rick L. Paul, Benjamin Place, James H. Yen
The National Institute of Standards and Technology (NIST) recently released SRM 2386 Avocado Powder which has value assignment for over 70 analytes. This material has certified values assigned for 22 analytes and non-certified values assigned for 53

Certification of Standard Reference Material(R) 1992 / ERM(R)-FD305 Zeta Potential - Colloidal Silica (Nominal Mass Fraction 0.15 %)

November 24, 2020
Author(s)
Yannic Ramaye, Vikram Kestens, J. Charoud-Got, S. Mazoua, G. Auclair, Tae Joon Cho, Blaza Toman, Vincent A. Hackley, T. Linsinger
This report describes the production of SRM 1992/ERM-FD305, silica particles suspended in a borate buffer, certified for electrophoretic mobility and zeta potential by electrophoretic light scattering (ELS). This material was produced following ISO 17034

Certification of Standard Reference Material(R) 1993 / ERM(R)-FD306 Zeta Potential - Colloidal Silica (Nominal Mass Fraction 2.2 %)

November 24, 2020
Author(s)
Yannic Ramaye, Vikram Kestens, J. Charoud-Got, S. Mazoua, G. Auclair, Tae Joon Cho, Blaza Toman, Vincent A. Hackley, T. Linsinger
This report describes the production of SRM 1993/ERM-FD306, silica particles suspended in a borate buffer, certified for electrophoretic mobility and zeta potential by electrophoretic light scattering (ELS). This material was produced following ISO 17034

Certification of Standard Reference Material(R) 955d, Toxic Elements and Metabolites in Frozen Human Blood

October 15, 2020
Author(s)
Lee L. Yu, Karen E. Murphy, Colleen E. Bryan Sallee, Thomas W. Vetter, Robert C. Hagwood, George C. Caceres, Stephen E. Long, J M. Jarrett, M A. Franklin, J Castro Georgi, D M. Jones, Robert Jones, Z Li, Y L. Sommer, D S. Tevis, K Wallon, C D. Ward, M Maras, S Erdahl, C Gilmer, M Wermers, H Woldeysus, K F. Mehigan, M Morrissette, Christopher D. Palmer, Patrick J. Parsons
Standard Reference Material (SRM) 955d is intended for use in validating analytical methods for measuring toxic elements and mercury species in human blood, and in value assigning locally produced control materials analyzed using the validated methods. A

Metrological Tools for the Reference Materials and Reference Instruments of the NIST Material Measurement Laboratory

July 15, 2020
Author(s)
Carlos R. Beauchamp, Johanna Camara, Jennifer Carney, Steven J. Choquette, Kenneth D. Cole, Paul C. DeRose, David L. Duewer, Michael Epstein, Margaret C. Kline, Katrice Lippa, Enrico Lucon, Karen W. Phinney, Maria Polakoski, Antonio Possolo, Katherine E. Sharpless, John R. Sieber, Blaza Toman, Michael R. Winchester, Donald Windover
The National Institute of Standards and Technology (NIST), formerly the National Bureau of Standards, was established by the U.S. Congress in 1901 and charged with establishing a measurement foundation to facilitate U.S. and international commerce. NIST

Certification of Standard Reference Material 3389 Ginsenoside Calibration Solution

May 10, 2019
Author(s)
Walter B. Wilson, Lane C. Sander, Benjamin J. Place, James H. Yen
Standard Reference Material (SRM) 3389 is intended as a calibration solution for use for the determination of ginsenosides in natural matrix samples. A unit of SRM 3389 consists of two different ampule solutions: (1) four ampules of a six-component mixture

Reference Material 8634: Ethylene Tetrafluoroethylene for Particle Size Distribution and Morphology

May 1, 2019
Author(s)
Dean C. Ripple, Srivalli Telikepalli, Kristen L. Steffens, Michael J. Carrier, Christopher B. Montgomery, Nicholas W. Ritchie, John Lu
Reference Material (RM) 8634 is a NIST particle standard produced from abraded ethylene tetrafluoroethylene (ETFE), a chemically inert polymer, that will help standardize and allow more accurate monitoring of subvisible proteinaceous particles in

Certification of Standard Reference Material(R) 2372a Human DNA Quantitation Standard

March 19, 2018
Author(s)
Erica L. Romsos, Margaret C. Kline, Natalia Farkas, David L. Duewer, Blaza Toman
Standard Reference Material (SRM) 2372a is intended for use in the value assignment of human genomic deoxyribonucleic acid (DNA) forensic quantitation materials. A unit of SRM 2372a consists of three well-characterized human genomic DNA materials

Certification of SRM 2493:Standard Reference Mortar for Rheological Measurements

October 4, 2017
Author(s)
Alex Olivas, Chiara C. Ferraris, Nicos Martys, Edward Garboczi, Blaza Toman, William L. George
Rheological measurements are often performed using a rotational rheometer. In this type of rheometer, the tested fluid is sheared between two surfaces, one of which acts as the rotating surface [1]. Usually, the rotational velocity is imposed and the