Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1376 - 1400 of 3361

Anatomy of Spin-Transfer Torque

July 1, 2002
Author(s)
Mark D. Stiles, A Zangwill
… component of a spin current that flows from a non-magnet into a ferromagnet is absorbed at the interface. We …

Reply to "Comment on: 'Ultrafast Demagnetization Measurements Using Extreme Ultraviolet Light: Comparison of Electronic and Magnetic Contributions'"

September 4, 2013
Author(s)
Justin Shaw, Thomas J. Silva, Hans Nembach, Emrah Turgut, Patrik Grychtol, Chan La-O-Vorakiat, Henry C. Kapteyn, Margaret M. Murnane, Stefan Mathias, Martin Aeschlimann, Claus Schneider, Daniel E. Adams
… Extreme Ultraviolet Light: Comparison of Electronic and Magnetic Contributions" are correct. The Comment of Vodungbo … (less than or equal to} 2%), below the noise level of the magnetic-asymmetry measurements. First, we use a few … Extreme Ultraviolet Light: Comparison of Electronic and Magnetic Contributions'" …

Constraints on the Possible Long-Range Orbital Ordering in LaCoO 3

January 1, 2014
Author(s)
Daniel P. Phelan, Peter M. Gehring
A neutron powder diffraction measurement was performed to distinguish between the proposed monoclinic (I2/a) structure of LaCoO 3, which is consistent with orbital ordering, and the rhombohedral (R3c) structure, which is inconsistent with orbital ordering

Controllable Positive Exchange Bias via Redox-Driven Oxygen Migration

March 21, 2016
Author(s)
Dustin A. Gilbert, Justin Olamit, Randy K. Dumas, Brian J. Kirby, Alexander J. Grutter, Brian B. Maranville, Elke Arenholz, Julie A. Borchers, Kai Liu
We have observed oxygen migration across buried interfaces in Gd^xdx^Fe 1-x/NiCoO films, which leads to tunable positive exchange bias over a relatively small cooling field range of 300 mT. The tunability is shown to be the result of an interfacial layer

Dimensional Evolution of Spin Correlations in the Magnetic Pyrochlore Yb 2 Ti 2 O 7

November 30, 2011
Author(s)
K. A. Ross, L. R. Yaraskavitch, M. Laver, Jason S. Gardner, J. A. Quilliam, S. Meng, J. B. Kycia, Deepak Singh, Th. Proffen, H. A. Dabkowska, B. D. Gaulin
… 2 Ti 2 O 7 displays unexpected quasi-two-dimensional (2D) magnetic correlations within a cubic lattice environment at … Dimensional Evolution of Spin Correlations in the Magnetic Pyrochlore Yb 2 Ti 2 O 7 …

Design and Experimental Verification of a 3D Magnetic EZ Antenna at 300 MHz

August 11, 2009
Author(s)
Christopher L. Holloway, Richard Ziolkowski, Chia-Ching Lin, J. A. Nielsen, M. H. Tanielian
… of the electrically small coax-fed three-dimensional (3D) magnetic EZ antenna were designed and tested. The final … Design and Experimental Verification of a 3D Magnetic EZ Antenna at 300 MHz …

ENVIRONMENTAL METABOLOMICS: NMR TECHNIQUES

December 8, 2013
Author(s)
Myrna Simpson, Dan Bearden
Environmental metabolomics is a rapidly growing area of research, and over the last decade the focus has been on organism responses to various types of environmental stressors (pollutants, nutritional shifts, and global climate change, for example)

Absolute radiation pressure detector using a diamagnetically levitating test mass

October 28, 2021
Author(s)
Anna Vaskuri, Daniel Rahn, Paul A. Williams, John H. Lehman
… mN/m) afforded by diamagnetic levitation above a permanent magnet array and a lock-in amplifier in the feedback loop to … the shuttle, and its position is restored by tilting the magnet array with a piezoelectric actuator. The closed-loop … and the interferometrically measured tilt angle of the magnet array. The system is demonstrated with a laser power …

Advances in Weld Hydrogen Sensors

June 1, 2002
Author(s)
David Olson, B. Mishra, R D. Smith, S. Niyomsoan, P. Termsuksawad, Y D. Park, V I. Kaydanov, Z Gavra, Ronald B. Goldfarb
Through the application of modern physics concepts, advanced hydrogen sensors are being developed for rapid determination of weld hydrogen content and distribution. Electronic, optical, and magnetic property measurements have demonstrated the ability to

Advantages of superconducting quantum interference device-detected magnetic resonance over conventional high-frequency electron paramagnetic resonance for characterization of nanomagnetic materials

May 16, 2005
Author(s)
Brant Cage, Stephen E. Russek, David Zipse, Naresh S. Dalal
… technique provides quantitative determination of the dc magnetic moment as a function of microwave power, magnetic field and temperature. The EPR spectra obtained do … of superconducting quantum interference device-detected magnetic resonance over conventional high-frequency electron …

Macrospin Models of Spin Transfer Dynamics

July 1, 2005
Author(s)
J Xiao, A Zangwill, Mark D. Stiles
The current-induced magnetization dynamics of a spin valve are studied using a macrospin (single-domain) approximation and numerical solutions of a generalized Landau-Lifshitz-Gilbert equation. For the purpose of quantitative comparison to experiment [S. I
Displaying 1376 - 1400 of 3361
Was this page helpful?