Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 176 - 200 of 370

Spectroscopic analysis of M- and N-intrashell transitions in Co-like to Na-like Yb ions

December 19, 2021
Author(s)
Yuri Ralchenko, Dipti Goyal, Roshani Silwal, Endre Takacs, Joan Dreiling, Samuel Sanders, Amy Gall, Hemalatha Rudramadevi, John Gillaspy
The M-intrashell spectra from Co-like Yb$^43+}$ through Na-like Yb$^59+}$ ions produced in an electron beam ion trap (EBIT) at the National Institute of Standards and Technology have been studied in the extreme ultraviolet (EUV) range. A few N-intrashell

Combining secondary ion mass spectrometry image depth profiling and single particle inductively coupled plasma mass spectrometry to investigate the uptake and biodistribution of gold nanoparticles in Caenorhabditis elegans

May 20, 2021
Author(s)
Monique Johnson, Joe Bennett, Antonio Montoro Bustos, Shannon Hanna, Andrei Kolmakov, Nicholas Sharp, Elijah Petersen, Christopher Sims, Bryant Nelson, Patricia Lapasset
… number of AuNPs within the nematode, ranging from 2 to 36 NPs depending on the size of AuNP. The complementary data …

Chopped Cold Neutron Beam Activation Analysis

May 17, 2021
Author(s)
Danyal J. Turkoglu, Heather H. Chen-Mayer
… results from test samples containing Se-77 (T1/2 = 17.36 s) and Yb-175m (T1/2 =0.0682 s). The chopper timing was … shown in a sample containing Yb-175m and Dy-165 (T1/2 = 75.4 s). …

Coupled-cavity ring-down spectroscopy technique

August 6, 2012
Author(s)
Jeremie B. Courtois, Joseph T. Hodges
… times as long as 0.50 ms, equivalent to a finesse of 6.4105 and an effective mirror transmittance of 4.9106. …

Tests of the Extended Lee Model Using Three Different Turbine Meters

June 20, 2012
Author(s)
Jodie G. Pope, John D. Wright, Sherry D. Sheckels
We report additional tests of our “extended Lee model” for calibrating turbine meters. The model accounts for 1) Reynolds number (Re) dependent drag and lift, 2) bearing static drag and 3) bearing viscous drag. Initially, we tested this model using a dual

Effects of Scanner Height on Fingerprint Capture

June 27, 2007
Author(s)
Mary Theofanos, Shahram Orandi, Ross J. Micheals, Brian Stanton, Nien F. Zhang
… sequence with a six inch high sensor ?a counter height of 36 inches (914mm) gives the fastest performance. ?a counter …

A summary of the Planck constant measurements using a watt balance with a superconducting solenoid at NIST

February 5, 2015
Author(s)
Stephan Schlamminger, Richard L. Steiner, Darine El Haddad, David B. Newell, Frank C. Seifert, Leon S. Chao, Ruimin Liu, Edwin R. Williams
… The final value of h measured with NIST-3 is h = 6.626 069 36(37) x 10^-34 Js. This result is 77(57) x 10^-9 … conventional value of the Planck constant given by h_90~ 4 /(KJn^2 RKn), where KJn and RKn denote the conventional …

Diffusion Barrier Cladding in Si/SiGe Resonant Interband Tunneling Diodes and Their Patterned Growth on PMOS Source/Drain Regions

January 1, 2003
Author(s)
N Jin, A T. Rice, P R. Berger, P E. Thompson, C Rivas, R Lake, S Sudirgo, J J. Kempisty, B Curanovic, S L. Rommel, K D. Hirschman, S K. Kurinec, P Chi, David S. Simons, S.J. Chung
Si/SiGe resonant interband tunnel diodes (RITD) employing delta-doping spikes that demonstrate negative differential resistance (NDR) at room temperature are presented. Efforts have focused on improving the tunnel diode peak-to-valley current ratio (PVCR)