Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1851 - 1875 of 2522

Molecular Basis of Lubrication

February 1, 2002
Author(s)
Stephen M. Hsu
Lubrication is an art that has been practiced for thousands of years from the early days of our human civilization. The study of lubricatin as a science began in the 17th century with the development of bearings and axles. In the early 20th century, the

Compressive Strengthening of Sapphire by Neutron Irradiation

May 9, 2001
Author(s)
T M. Regan, D C. Harris, R M. Stroud, J R. White, D W. Blodgett, K C. Baldwin, J A. Miragliotta, M E. Thomas, M J. Linevsky, J W. Giles, T A. Kennedy, M Fatemi, David R. Black
… decreases the flexure strength of sapphire at 600 C by 0%-20% in some experiments. However, the c-plane ring-on-ring …

Using BEES to Select Cost-Effective Green Products

March 1, 2001
Author(s)
Barbara C. Lippiatt, A Boyles
The BEES (Building for Environmental and Economic Sustainability) version 2.0 software implements a rational, systematic technique for selecting environmentall and economically balanced building products. The technique is based on consensus standards and

Vortex Pinning in Microindented Yba 2 Cu 3 O 7-x Single Crystals

August 1, 2000
Author(s)
Marina Turchinskaya, Douglas T. Smith, Alexander L. Roytburd, Debra L. Kaiser
… at the surface of a twinned single crystal of Yba 2 Cu 3 O 7-δ as a function of applied magnetic field, H da^ (O to 68 … of an indentation is {approximately equal to} 0.4 mT/ m at 20-60 K. The average induction gradient and, thus, the … Vortex Pinning in Microindented Yba 2 Cu 3 O 7-x Single Crystals …

Microhotplate Gas Sensor Arrays

November 18, 1999
Author(s)
Richard E. Cavicchi, Stephen Semancik, R M. Walton, B Panchapakesan, Don L. DeVoe, M I. Aquino-Class, J D. Allen, John S. Suehle
… Millisecond temperature changes in the range of 20 degrees C to over 500 degrees C are employed to alter the …

Improving the Accuracy of Particle Analysis

July 1, 2000
Author(s)
John A. Small, J R. Michael, Dale E. Newbury
… The results indicate that the beam energies greater than 20 keV the error distribution is large, ranging from a high … the error distributions for beam energies less than 20 keV drops dramatically with the smallest values, ranging …

A Frequency Stabilized Laser Array for Use in Displacement Metrology

February 17, 2000
Author(s)
J Pedulla, R Deslattes, John R. Lawall
… whose accuracy requires a frequency stability of 20 kHz. In addition, each laser must be stable on both short … reduce the error in the iodine-stabilized laser to between 20-30 kHz rms (Fig. 1). To measure the quality of the …

A Frequency Stabilized Laser Array for Use in Displacement Metrology

February 1, 2000
Author(s)
J Pedulla, R Deslattes, John R. Lawall
… whose accuracy requires a frequency stability of 20 kHz. In addition, each laser must be stable on both short … reduce the error in the iodine-stabilized laser to between 20 kHz to 30 kHz rms (Fig. 1).To measure the quality of the …

The Strategic Role of 2D Nanomaterials in Grid Modernization

January 16, 2026
Author(s)
Matthew Glasscott, James Burgess, Peter Byrley, Maria Fernanda Campa, Mark Griep, Alexander Kirk, Stephanie Mack, Birgit Schwenzer, Ryan Welch, Elisabeth Mansfield
… of thermoelectrics from the benchmark 5% to over 20%. Regarding energy storage, the tunability of these …

ReRAM/CMOS Array Integration and Characterization via Design of Experiments

July 21, 2025
Author(s)
Imtiaz Hossen, William Borders, Advait Madhavan, Shweta Joshi, Patrick Braganca, Jabez McClelland, Brian Hoskins, Gina Adam
No two fabricated ReRAM devices are alike. This experimental reality is evident when large device arrays have to be characterized and optimized for system-level performance. Each device can have their individual optimal set of operating parameters that

Time evolution of a pumped molecular magnet - a time resolved inelastic neutron scattering study

January 1, 2025
Author(s)
T. Reeder, Paraj Titum, J. Kindervater, Qiang Ye, Jose Rodriguez Rivera, Yiming Qiu, Nicholas C. Maliszewskyj, T. McQueen, Collin L. Broholm
… energy states |λ ≥ 3 were extracted during and after 20 s long microwave pulses incident along the (101) direction … thermalization time scales ranging from 1.6(2) s to 5.7(2) s depending on the power level. This contrasts with the …
Displaying 1851 - 1875 of 2522
Was this page helpful?