An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Heather J. Patrick, Ravikiran Attota, Bryan M. Barnes, Thomas A. Germer, Michael T. Stocker, Richard M. Silver, Michael R. Bishop
We demonstrate optical critical dimension measurement of lines in silicon grating targets using back focal plane scatterfield microscopy. In this technique...
Room temperature p-type GaSb bulk coupled mode spectra were measured as a function hole concentration. These spectra were obtained using an optical system based...
Recently it has been demonstrated that a careful treatment of both longitudinal and transverse matrix elements in electron energy loss spectra can explain the...
Ian R. Coddington, William C. Swann, Nathan R. Newbury
The broadband, coherent nature of narrow-linewidth fiber frequency combs is exploited to measure the full complex spectrum of a molecular gas through...
Magnetic properties of NiO nanoparticles (NP) prepared by the sol-gel method in the size range D = 5 nm to 20 nm, with and without oleic acid (OA) coating, are...
Richard E. Cavicchi, C Avedisian, Paul M. McEuen, Xinjian Zhou, Wilbur S. Hurst, Joseph T. Hodges
We report the electrical characteristics of two substrate-supported metallic single walled carbon nanotubes (SWNT) at temperatures up to 573 K over a range of...
Christopher D. Zangmeister, Roger D. van Zee, Steven W. Robey, N E. Gruhn, Yuxing Yao, J M. Tour
Photoemission spectra of para-phenylene-ethynylene thiols chemisorbed on gold have been measured. Four compounds were studied: 4,4'-bis(phenylethynyl)...
Balasubramanian Muralikrishnan, Jack A. Stone Jr., John R. Stoup
Several radiometric and photometric measurements depend on high accuracy area measurement of precision apertures. Some apertures have sharp edges and are...
Michael R. Souryal, E G. Larsson, B M. Peric, B R. Vojcic
This paper derives new soft decision metrics for coded orthogonal signaling in impulsive noise, more specifically symmetric alpha-stable noise. For the case of...
Designing and managing an economys technology infrastructure requires both accurate economic models and data to drive them. Previous models treat technology as...
Ravikiran Attota, Richard M. Silver, Ronald G. Dixson
We present a detailed experimental study of a new through-focus technique to measure line width (CD) with nanometer sensitivity using a bright field optical...
procedure has been developed, based on a dilute-solution model of the liquid phase and the rigorous virial expansion for the vapor phase, for modeling the vapor...
Marek Franaszek, Geraldine S. Cheok, Christoph J. Witzgall
3D imaging systems are line of sight instruments and multiple scans from different locations are often needed to get a good representation of an entire scene...
We discuss the dynamics of a Bose-Einstein condensate of atoms suddenly coupled to a condensate of molecules by an optical or magnetic Feshbach resonance. Three...
David T. Read, Walter Gerstle, Stewart Silling, Vinod K. Tewary, Richard Lehoucq
A theoretical framework, based upon the peridynamic model, is presented for analytical and computational simulation of electromigration. The framework allows...
We describe an automated apparatus for the calibration of hydrometers by hydrostatic weighing (Cuckow s method). The apparatus uses a laser light sheet and a...
Graphene nanoribbons with both armchair- and zigzag-shaped hydrogen-passivated edges (AGNR and ZGNR) have band gaps. Son et al. showed that the gap s value...
To assure quality measurements, the algorithms used in data analysis need to be demonstrably correct. In practice, however, some less transparent or more...
Ruby I. Chen, Nathan D. Gallant, Jack R. Smith, Matt J. Kipper, Carl G. Simon Jr.
From a biomaterials perspective, three primary events can occur when a biodegradable polymer is implanted in vivo: 1) polymer degradation, 2) protein adsorption...
A scanning thermal microscope (SThM) was used to investigate the spatial and temporal distribution of temperature in electrical interconnect structures designed...
D J. Robichaud, Joseph T. Hodges, D Lisak, Charles E. Miller, Mitchio Okumura
We describe a high-precision method for measuring pressure shifting of absorption lines. The technique involves the acquisition of high-resolution spectra using...
The purpose of this study was to measure hydroxyl ion diffusion through dentinal tubules. Eighty single-rooted teeth were instrumented and divided into 8 groups...
H M. Lawler, J J. Rehr, F Vila, SD Dalosto, Eric L. Shirley, Zachary H. Levine
A first-principles approach is presented for calculations of optical to ultraviolet spectra including excitonic effects. The approach is based on the Bethe...
Michael W. Cresswell, Richard A. Allen, William F. Guthrie, Christine E. Murabito, Ronald G. Dixson, Amy Hunt
CD (Critical Diminsion) measurements have been extracted from SEM (Scanning Electron Microscopy) and HRTEM (High Resolution Transmission Electron Microscopy)...
This paper is mainly concerned with multi-channel transmission of real-time information such as video over multi-hop ad-hoc links. We propose two multi-channel...
The use of physical identifiable characteristics (biometrics) in border and transportation security has increased since 9/11. Currently, the United States...
Steven W. Brown, Joseph P. Rice, David W. Allen, Maritoni A. Litorja, Karel Zuzak, Edward Livingston
As optical imaging modalities gain acceptance for medical diagnostics and become common in clinical applications, standardized protocols to quantitatively...