Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Leila R. Vale (Fed)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 26 - 50 of 128

Low noise kinetic inductance traveling-wave amplifier using three-wave mixing

October 1, 2015
Author(s)
Michael R. Vissers, Robert P. Erickson, Leila R. Vale, Xian Wu, Gene C. Hilton, David P. Pappas
We have fabricated a wide-bandwidth, high dynamic range, low noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By

High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential

May 1, 2015
Author(s)
W.Bertrand (Randy) Doriese, Joseph Fowler, Daniel Swetz, Cherno Jaye, Daniel A. Fischer, Carl D. Reintsema, Douglas Bennett, Leila R. Vale, Gene C. Hilton, Dan Schmidt, Joel Ullom, Jens Uhlig, Ujjwal Mandal, Galen O'Neil, Luis Miaja Avila, Young I. Joe, wilfrid fullagar, Fredrick P. Gustafsson, Dharma Kurunthu, Villy Sundstrom
X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low

Integration of TES microcalorimeters with microwave SQUID multiplexed readout.

December 22, 2014
Author(s)
Douglas A. Bennett, John A. Mates, Johnathon D. Gard, Andrew Hoover, Micheal Rabin, Carl D. Reintsema, Daniel R. Schmidt, Leila R. Vale, Joel N. Ullom
The demonstration of a microwave SQUID multiplexed readout of transition-edge sensor (TES) microcalorimeters has the potential to dramatically expand the scale of arrays of TESs. In this manuscript we discuss recent work to develop an instrument for high

Table-top ultrafast x-ray microcalorimeter spectrometry for molecular structure

March 26, 2013
Author(s)
Jens (. Uhlig, William B. Doriese, Joseph W. Fowler, Daniel S. Swetz, Carl D. Reintsema, Douglas A. Bennett, Leila R. Vale, Gene C. Hilton, Kent D. Irwin, Joel N. Ullom, Ilari Maasilta, Wilfred Fullagar, Niklas Gador, Sophie Canton, Kimmo Kinnunen, Villy Sundstrom
This work presents an x-ray absorption measurement by use of ionizing radiation generated by a femtosecond pulsed laser source. The spectrometer was a microcalorimetric array whose pixels are capable of accurately measuring energies of individual radiation

Dual-polarization sensitive MKIDs for far infrared astrophysics

December 12, 2012
Author(s)
Johannes Hubmayr, James A. Beall, Daniel T. Becker, Hsiao-Mei Cho, Brad Dober, Mark Devlin, Anna E. Fox, Dale Li, Michael D. Niemack, David P. Pappas, Leila R. Vale, Kent D. Irwin, Gene C. Hilton
We present the design for arrays of dual-polarization sensitive, superconducting sensors for far infrared astrophysics. Each pixel is feedhorn-coupled and consists of orthogonal, lumped-element kinetic inductance detectors (LEKIDs) both fabricated in the

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

September 28, 2012
Author(s)
Douglas A. Bennett, Robert D. Horansky, Daniel R. Schmidt, Andrew Hoover, Ryan Winkler, Bradley K. Alpert, James A. Beall, William B. Doriese, Joseph W. Fowler, Gene C. Hilton, Kent D. Irwin, Nathan J. Hoteling, Vincent Y. Kotsubo, John A. Mates, Galen C. O'Neil, Michael W. Rabin, Carl D. Reintsema, Francis J. Schima, Daniel S. Swetz, Leila R. Vale, Joel N. Ullom
Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gammaray microcalorimeters, based on transition-edge sensors (TESs)

Demonstration of code-division multiplexing for x-ray microcalorimeters

February 13, 2012
Author(s)
Greg Stiehl, W.Bertrand (Randy) Doriese, Gene C. Hilton, Kent D. Irwin, Carl D. Reintsema, Dan Schmidt, Daniel Swetz, Joel Ullom, Leila R. Vale, Joseph Fowler
We demonstrate the code-division multiplexing (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the

Advanced Code-Division Multiplexers for Superconducting Detector Arrays

February 11, 2012
Author(s)
Kent D. Irwin, Hsiao-Mei Cho, William B. Doriese, Joseph W. Fowler, Gene C. Hilton, Michael D. Niemack, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Leila R. Vale
Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays

Optimization of the TES-bias circuit for a multiplexed microcalorimeter array

January 27, 2012
Author(s)
William B. Doriese, Bradley K. Alpert, Joseph W. Fowler, Gene C. Hilton, Alex S. Hojem, Kent D. Irwin, Carl D. Reintsema, Daniel R. Schmidt, Greg Stiehl, Daniel S. Swetz, Joel N. Ullom, Leila R. Vale
In the detector-bias circuit of a transition-edge-sensor (TES) microcalorimeter, the TES-shunt resistor (Rsh) and the thermal conductance to the cryogenic bath (G) are often considered to be interchangeable knobs with which to control detector speed

Optimization and analysis of code-division multiplexed TES microcalorimeters

January 20, 2012
Author(s)
Joseph W. Fowler, William B. Doriese, Gene C. Hilton, Kent D. Irwin, Daniel R. Schmidt, Greg Stiehl, Daniel S. Swetz, Joel N. Ullom, Leila R. Vale
We are developing code-division multiplexing (CDM) readout systems for TES arrays for good scalability to large multiplexing factors. We report high energy resolution x-ray measurements made through four-channel CDM that employ a flux-summing architecture

Quantum superposition of a single microwave photon in two different colour states

July 3, 2011
Author(s)
Eva A. Zakka-Bajjani, Francois E. Nguyen, Minhyea Lee, Leila R. Vale, Raymond Simmonds, Joe Aumentado
The ability to manipulate photonic states is an important tool for quantum information processing. In cavity quantum electrodynamics (QED), coupling between bosonic modes has, until now, required a qubit to mediate the interaction. As an alternative, it is

Strongly quadrature-dependent noise in superconducting microresonators measured at the vacuum-noise limit

June 9, 2011
Author(s)
Jiansong Gao, Kent D. Irwin, Gene C. Hilton, John A. Mates, Daniel R. Schmidt, Leila R. Vale, Konrad W. Lehnert, Francois Mallet, Jonas Zmuidzinas
We report noise measurement of superconducting micro-resonators with a Josephson parametric amplifier. These resonators show significant amount of frequency noise caused by surface two-level systems. However, in the dissipation quadrature, no excess noise

Effect of metal/substrate interfaces on radio-frequency loss in superconducting coplanar waveguides

November 8, 2010
Author(s)
David S. Wisbey, Jiansong Gao, Fabio C. da Silva, Jeffrey S. Kline, Michael Vissers, David P. Pappas, Leila R. Vale
Microscopic two-level systems (TLSs) are known to contribute to loss in resonant superconducting microwave circuits. This loss increases at low power and temperatures as the TLSs become unsaturated. We find that the loss is dependent on both the substrate

An Analytical Model for Pulse Shape and Electrothermal Stability in Two-Body Microcalorimeters

September 9, 2010
Author(s)
Douglas A. Bennett, Robert D. Horansky, Daniel R. Schmidt, Daniel S. Swetz, Leila R. Vale, Joel N. Ullom, Andrew Hoover, Michael W. Rabin, Nathan J. Hoteling
High resolution superconducting gamma-ray sensors show potential for the more accurate analysis of nuclear material. These devices are part of a larger class of microcalorimeters and bolometers based on transition edge sensors (TESs) that have two distinct

Code-division SQUID multiplexing

April 23, 2010
Author(s)
Michael D. Niemack, Kent D. Irwin, Joern Beyer, Hsiao-Mei Cho, William B. Doriese, Gene C. Hilton, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Leila R. Vale
Multiplexed superconducting quantum interference device (SQUID) readout systems are a critical technology for measuring large arrays of superconducting transition-edge sensor (TES) detectors. Current successful SQUID multiplexing architectures are

Superconductor Science and Technology

February 22, 2010
Author(s)
Kent D. Irwin, Michael D. Niemack, Joern Beyer, Hsiao-Mei Cho, William B. Doriese, Gene C. Hilton, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Leila R. Vale
Multiplexed superconducting quantum interference device (SQUID) amplifiers have recently enabled the deployment of kilopixel arrays of superconducting transition-edge sensor (TES) detectors on a variety of receivers for astrophysics. Existing multiplexing

Improved Isotopic Analysis With a Large Array of Gamma-Ray Microcalorimeters

June 30, 2009
Author(s)
Nikhil Jethava, Joel N. Ullom, Douglas A. Bennett, William B. Doriese, James A. Beall, Gene C. Hilton, Robert D. Horansky, Kent D. Irwin, Eric Sassi, Leila R. Vale, Minesh K. Bacrania, Andrew Hoover, P. J. Karpius, Michael W. Rabin, Clifford R. Rudy, Duc T. Vo
We present results from the largest array of gamma-ray microcalorimeters operated to date. The microcalorimeters consist of Mo/Cu transition-edge sensors with attached Sn absorbers. The detector array contains 66 pixels each with an active area 2.25 mm 2

High resolution X-ray transition-edge sensor cooled by tunnel junction refrigerators and operated above the transition temperature

April 21, 2008
Author(s)
Nathan A. Tomlin, Galen C. O\'Neil, James A. Beall, Gene C. Hilton, Kent D. Irwin, Daniel R. Schmidt, Leila R. Vale, Joel N. Ullom
We demonstrate cooling of an X-ray transition-edge sensor (TES) using solid-state refrigerators based on normal-metal / insulator / superconductor (NIS) tunnel junctions. We are able to operate the TES at a bath temperature of 260 mK, which is 75 mK above

Analysis of Nuclear Material by Alpha Spectroscopy with a Transition-Edge Microcalorimeter

January 26, 2008
Author(s)
Rob Horansky, Joel Ullom, James A. Beall, Gene C. Hilton, Kent D. Irwin, Leila R. Vale, Don Dry, Stephen Lamont, Clifford R. Rudy, Michael W. Rabin
We present measurements from a cryogenic microcalorimeter designed to detect alpha particles. The enhanced resolution of microcalorimeter alpha detectors will provide new capabilities for actinide analysis. We demonstrate a spectral resolution of 2.4 keV

A TDMA Hybrid SQUID Multiplexer

January 25, 2008
Author(s)
Carl D. Reintsema, James A. Beall, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Kent D. Irwin, Dan Schmidt, Joel Ullom, Leila R. Vale, Yizi Xu
We have developed a multiplexed read-out for transition edge sensors based on a hybrid time- and frequency-domain basis set, similar to that used in time-division multiple-access (TDMA) mobile phones. The hybrid basis set uses bandwidth more efficiently

Large array of multiplexed gamma-ray microcalorimeters for nuclear-materials analysis

January 24, 2008
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Michael W. Rabin, Minesh K. Bacrania, Stephen Lamont, Andrew Hoover, Clifford R. Rudy, Duc Vo, C. K. Stahle, Kevin R. Boyce, Larry E. Brown, Jonathan M. King, F. S. Porter
We are developing a gamma-ray spectrometer for the analysis of nuclear materials based on an array of superconducting transition-edge-sensor microcalorimeters. The instrument includes eight columns of time-division-SQUID multiplexing circuitry capable of

Operation of an X-ray transition-edge sensor cooled by tunnel junction refrigerators

January 19, 2008
Author(s)
Nathan A. Tomlin, James A. Beall, Gene C. Hilton, Kent D. Irwin, Galen O'Neil, Dan Schmidt, Leila R. Vale, Joel Ullom
We demonstrate successful cooling of an X-ray transition-edge sensor (TES) using solid-state refrigerators based on normal-metal/insulator/superconductor (NIS) tunnel junctions. Above the TES transition temperature (Tc), we use Johnson noise thermometry to

Demonstration of a Multiplexer of Dissipationless SQUIDs}

January 18, 2008
Author(s)
John Mates, Gene C. Hilton, Kent D. Irwin, Leila R. Vale, Konrad Lehnert
We report on the development of a microwave SQUID multiplexer for reading out arrays of low-temperature detectors. In this frequency-division multiplexer, each SQUID couples to a high-Q superconducting resonator so that flux through the SQUID shifts the

Multiplexed microcalorimeter arrays for precision measurements from microwave to gamma-ray wavelengths

August 21, 2007
Author(s)
Joel Ullom, W.Bertrand (Randy) Doriese, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, Terrence J. Jach, John Mates, Nathan A. Tomlin, Galen O'Neil, Carl D. Reintsema, Nicholas Ritchie, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Andrew Hoover, Clifford R. Rudy, Derek Tournear, Duc Vo, Michael W. Rabin
Cryogenic microcalorimeters are a promising technology for ultrasensitive measurements of electromagnetic radiation from microwave to gamma-ray wavelengths. Cryogenic microcalorimeters derive their exquisite sensitivity from the minimal thermal noise at

A 14-pixel, multiplexed array of gamma-ray microcalorimeters with 47 eV energy resolution at 103 keV

May 9, 2007
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Leila R. Vale, Yizi Xu, Barry L. Zink, Andrew Hoover, Michael W. Rabin, Clifford R. Rudy, Duc Vo
We present a prototype for a high-energy-resolution, high-count-rate, gamma-ray spectrometer intended for nuclear forensics and international nuclear safeguards. The prototype spectrometer is an array of 14 transition-edge-sensor microcalorimeters with an
Was this page helpful?