Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Robert R. Zarr (Assoc)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 1 - 25 of 43

Thermal Properties of Pyroceram Code 9606

October 12, 2021
Author(s)
Daniel R. Flynn, James H. Yen, James J. Filliben, Robert R. Zarr, E M. Hohlfeld
In the late 1950s, Corning Glass Works measured the heat capacity, thermal diffusivity, and thermal expansion of Pyroceram Code 9606. In the early 1960s the National Bureau of Standards (NBS) measured the thermal diffusivity and the thermal conductivity of

Certification of Standard Reference Material(R) 1450e Fibrous Glass Board

April 17, 2020
Author(s)
Robert R. Zarr, Nathanael A. Heckert
Thermal conductivity measurements at and near room temperature are presented as the basis for certified values of thermal conductivity for SRM 1450e, Fibrous Glass Board. The meas-urements have been conducted in accordance with a randomized full factorial

SUPPLEMENTARY COMPARISON CCT Supplementary comparison S2 on thermal conductivity measurements of insulating materials by guarded hot plate

January 1, 2020
Author(s)
Bruno Hay, Robert R. Zarr, Clark Stacey, Nikolay Sokolov, Leonel Lira Cortes, Ulf Hammerschmidt, Jintao Zhang, Jean Remy Filtz, Fleurence N.
Seven National Metrology Institutes (NMIs) from France, United States, United Kingdom, Russia, Mexico, China and Germany participated in an inter-laboratory comparison on thermal conductivity measurements by the Guarded Hot Plate method. This action was

Historical Review of the Metered Section Area for Guarded Hot Plates

December 31, 2019
Author(s)
Robert R. Zarr, Stacy M. Bruss, David McElroy
Results of an extensive literature review and investigation of the metered section area for the guarded-hot-plate method, standardized as ASTM C177, Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means

Sensitivity Analysis Affecting the Calibration of Heat-Flow-Meter Apparatus

July 1, 2019
Author(s)
Robert R. Zarr, Sergio A. Carvajal, James J. Filliben
Results and analysis of a sensitivity study of four procedural variables on the calibration response of two commercial heat-flow-meter apparatus in compliance with ASTM Test Method C 518 are presented. The apparatus ranged in plate size from 305 mm by 305

Comparison of Models for Heat Transfer in High-Density Fibrous Insulation

May 13, 2019
Author(s)
Sergio A. Carvajal, Edward Garboczi, Robert R. Zarr
This paper evaluates different models for calculating the effective thermal conductivity of fibrous insulation by comparing predicted values with certified values of Standard Reference Material 1450c, Fibrous Glass Board. The fiber diameter distribution

Collaborative guarded-hot-plate tests between the Laboratoire national de metrologie et d’essais and the National Institute of Standards and Technology

January 20, 2017
Author(s)
Robert R. Zarr, William F. Guthrie, Bruno Hay, Alain Koenen
A collaborative study to compare the long-term measurement performance between guardedhot- plate facilities at the Laboratoire national de métrologie et d’essais (LNE) in France and the National Institute of Standards and Technology (NIST) in the United

Bilateral NMI Comparison of Guarded-Hot-Plate Apparatus

April 27, 2014
Author(s)
Alain Koenen, Robert R. Zarr, William F. Guthrie
Two national metrology laboratories (NMI) have conducted an international interlaboratory comparison on thermal conductivity on two thermal insulation reference materials. The Laboratoire national de métrologie et d'Essais (LNE) from France and the

Metrological Traceability for Guarded-Hot-Plate Apparatus

May 9, 2013
Author(s)
Robert R. Zarr
An approach for establishing metrological traceability for measurement results from guarded-hot-plate apparatus consistent with policy at the National Institute of Standards and Technology (NIST) is presented. A brief example for initiating met-rological

Analysis of Thermal-Conductivity Measurement Data from International Comparison of National Laboratories

June 19, 2012
Author(s)
Bruno Hay, Robert R. Zarr, Clark Stacey, Leonel Lira Cortes, Ulf Hammerschmidt, Nikolay Sokolov, J.T. Zhang, Jean Remy Filtz
For the first time under the auspices of the Bureau International des Poids et Mesures (BIPM), seven national metrology institutes (NMIs) participated in an international interlaboratory comparison on thermal-conductivity measurements by the guarded hot

SRM 1450d, Fibrous-Glass Board, for Thermal Conductivity from 280 K to 340 K

August 1, 2011
Author(s)
Robert R. Zarr, Amanda C. Harris, John F. Roller, Stefan D. Leigh
Thermal conductivity measurements at and near room temperature are presented as the basis for certified values of thermal conductivity for SRM 1450d, Fibrous Glass Board. The measurements have been conducted in accordance with a randomized full factorial

Assessing the Measurement Uncertainty of Thermophysical Properties

September 2, 2009
Author(s)
Robert R. Zarr
A generalized approach for the expression of measurement uncertainty consistent with current international practice is presented. The approach is applicable to all kinds of quantitative measurements including measurements of thermophysical properties. A

International Comparison on Thermal Conductivity Measurements of Insulating Materials by Guarded Hot Plate

September 2, 2009
Author(s)
Bruno Hay, Leonel Lira Cortes, Benoit Doucey, Jean Remy Filtz, Nikolay Sokolov, Clark Stacey, Robert R. Zarr, Jintao Zhang
An inter-laboratory comparison on thermal conductivity measurements of insulating materials is currently organized under the auspices of the Bureau International des Poids et Mesures (BIPM). Thermal conductivity measurements are carried out by seven