Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 23226 - 23250 of 74202

NIST Test Personal Identity Verification (PIV) Cards

July 12, 2012
Author(s)
David A. Cooper
In order to facilitate the development of applications and middleware that support the Personal Identity Verification (PIV) Card, NIST has developed a set of test PIV Cards and a supporting public key infrastructure. This set of test cards includes not

Testing Environments for Assessing Conformance and Interoperability

July 12, 2012
Author(s)
Robert D. Snelick, Leonard E. Gebase
We present a classification framework of testing environments that support conformance and interoperability testing of distributed systems. We describe each testing environment and state the applicability and requirements placed on a realization of a

Data Dependency on Measurement Uncertainties in Speaker Recognition Evaluation

July 11, 2012
Author(s)
Jin Chu Wu, Alvin F. Martin, Craig S. Greenberg, Raghu N. Kacker
The National Institute of Standards and Technology conducts an ongoing series of Speaker Recognition Evaluations (SRE). Speaker detection performance is measured using a detection cost function defined as a weighted sum of the probabilities of type I and

Determination of graphene work function and graphene-insulator-semiconductor band alignment by internal photoemission spectroscopy

July 11, 2012
Author(s)
Rusen Yan, Qin Zhang, Wei Li, Irene G. Calizo, Tian T. Shen, Curt A. Richter, Angela R. Hight Walker, Xuelei X. Liang, David J. Gundlach, Nhan Van Nguyen, Huili G. Xing, Alan Seabaugh
We determined the band alignment of a graphene-oxide-silicon structure using internal photoemission spectroscopy. From the flatband voltage and Dirac voltage we infer a 4.3  10e11 cm-2 negative extrinsic charge present on the graphene surface. Also, we

Structural and biochemical studies of a plant formamidopyrimidine-DNA glycosylase reveal why eukaryotic Fpg glycosylases do not excise 8-oxoguanine.

July 11, 2012
Author(s)
M Miral Dizdar, Pawel Jaruga, Susan Duclos, Pierre Aller, Susan Wallace, Susan Doublie
Formamidopyrimidine-DNA glycosylase (Fpg; MutM) is a DNA repair enzyme widely distributed in bacteria. Fpg recognizes and excises oxidatively modified purines, 4,6-diamino-5-formamidopyrimidine, 2,6-diamino-4-hydroxy-5-formamidopyrimidine and 8-oxoguanine

Switching Mechanisms in Flexible Solution-Processed TiO2 Memristors

July 11, 2012
Author(s)
Joseph L. Tedesco, Laurie Stephey, Madelaine H. Hernandez, Curt A. Richter, Nadine Gergel-Hackett
Memristors are emerging as unique electrical devices with potential applications in memory, reconfigurable logic, and biologically-inspired computing. Due to the novelty of these devices, the complete details of their switching mechanism are not yet well

A Restricted English for Constructing Ontologies (RECON)

July 10, 2012
Author(s)
Edward J. Barkmeyer Jr., Andreas K. Mattas
Verifying correctness of stated facts, rules, and term definitions for an industrial domain of work requires the contributions of experts in the domain. Conversely, use of automated reasoning technologies to assist in making industry decisions and

Preparing for and Responding to CA Compromise and Fraudulent Certificate Issuance

July 10, 2012
Author(s)
Paul Turner, William Polk, Elaine B. Barker
As the use of Public Key Infrastructure (PKI) and digital certificates (e.g., the use of Transport Layer Security [TLS] and Secure Sockets Layer [SSL]) for the security of systems has increased, the certification authorities (CAs) that issue certificates

Verification of the Back-EMF Method for Piston Velocity Measurements

July 10, 2012
Author(s)
Ray Radebaugh, Michael A. Lewis, Peter E. Bradley
Linear compressors are used to drive pulse tube or Stirling cryocoolers, and they can be used as expanders in place of inertance tubes when inertance tubes cannot provide sufficient phase shifts between flow and pressure. Commercial linear compressors

A method for comparing remote optical clocks over a free-space optical link

July 9, 2012
Author(s)
William C. Swann, Fabrizio R. Giorgetta, Ian R. Coddington, Esther Baumann, Jean-Daniel Deschenes, Laura C. Sinclair, Alexander M. Zolot, Nathan R. Newbury
We demonstrate a method to compare optical clocks approaching 10 -17 uncertainties through the exchange of optical pulses from phase-locked frequency combs. We discuss results over a 120 m air path and prospects for longer distances.

Continuous-variable quantum compressed sensing

July 9, 2012
Author(s)
Yi-Kai Liu, Matthias Ohliger, Vincent Nesme, David Gross, Jens Eisert
We introduce a novel method to faithfully reconstruct unknown quantum states that are approximately low-rank, using only a few measurement settings. The method is general enough to allow for measurements from a continuous family, and is also applicable to

Power Density Rating for Embedded Resistors

July 9, 2012
Author(s)
Jan Obrzut, Jason D. Ferguson, MIchael H. Azarian
The Power Density Ratting (PDR) for Embedded Resistors test method covers procedures for the demonstration of the ability to operate the embedded device safely within nominal tolerance, at rated power, and to withstand the transient voltage waves resulting

Reference Correlation of the Thermal Conductivity of Sulfur Hexafluoride from the Triple Point to 1000 K and up to 150 MPa

July 9, 2012
Author(s)
Marc J. Assael, I.A. Koini, K.D. Antoniadis, Marcia L. Huber, Ilmutdin M. Abdulagatov, Richard A. Perkins
This paper contains new, representative reference equations for the thermal conductivity of SF6. The equations are based in part upon a body of experimental data that has been critically assessed for internal consistency and for agreement with theory

Room Temperature Acoustic Transducers for High-Temperature Thermometry

July 9, 2012
Author(s)
Dean C. Ripple, William E. Murdock, Gregory F. Strouse, Keith A. Gillis, Michael R. Moldover
We have successfully conducted highly-accurate, primary acoustic thermometry at 600 K using a sound source and a sound detector at room temperature. We describe the source, the detector, and the ducts that connected them to our cavity resonator. This
Displaying 23226 - 23250 of 74202
Was this page helpful?