Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 22901 - 22925 of 73741

Common Mass Spectral Fragmentation Patterns of Organic Compound Families

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table provides a guide to the identification and interpretation of commonly observed mass spectral fragmentation patterns for common organic functional groups [1-10]. It is of course highly desirable to augment mass spectroscopic data with as

Common Mass Spectral Fragments Lost

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table gives a list of neutral species that are most commonly lost when measuring the mass spectra of organic compounds. The list is suggestive rather than comprehensive, and should be used in conjunction with other sources [1-5]. The listed

Common Spurious Infrared Absorption Bands

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table provides some of the common potential sources of spurious infrared absorptions that might appear on a spectrum.

Common Spurious Signals Observed in Mass Spectrometers

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table provides guidance in the recognition and interpretation of spurious signals (m/z peaks) that will sometimes be observed in measured mass spectra [1]. Often, the occurrence of these signals can be predicted by the recent history of the

Common Spurious Signals Observed in Mass Spectrometers

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table provides guidance in the recognition of spurious signals (m/z peaks) that will sometimes be observed in measured mass spectra, especially when the mass spectrometer is interfaced to a gas chromatograph [1]. Often, the occurrence of

Detection of outliers in measurements

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The field of outlier detection and treatment is considerable, and a rigorous mathematical discussion is well beyond any treatment that is possible here. Moreover, the practice in the treatment of analytical results is usually simplified, since the number

Detectors for Gas Chromatography

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table provides some comparative data for the selection and operation of the more common detectors applied to capillary and packed column gas chromatography [1-8]. For more detailed information regarding operation and interpretation of results

Electro-Mechanical Properties of Graphene Drumheads

June 22, 2012
Author(s)
Nikolai N. Klimov, Suyong S. Jung, Shuze Zhu, Teng Li, C. Alan Wright, Santiago Solares, David B. Newell, Nikolai B. Zhitenev, Joseph A. Stroscio
The electro-mechanical properties of a suspended graphene layer are determined by scanning tunneling microscopy (STM) and spectroscopy (STS) measurements and computational simulations of the graphene membrane mechanics and morphology. The graphene membrane

Eluotropic Values of Solvents on Octadecylsilane and Octylsilane

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table provides, for comparative purposes, eluotropic values on bonded octadecyl silane (ODS) and octyl silane (OS) for common solvents.[1-3] For additional information on common, specific and chiral stationary phases for HPLC, and for

Indicators for Acids and Bases

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table lists the most common indicators together with their pH range and colors in acidic and basic media. Since the color change is not instantaneous at the pKa value, a pH range is given where a combination of colors is present. This pH

Middle-Range Infrared Absorption Correlation Charts

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following charts provide characteristic middle range infrared absorptions obtained from particular functional groups on molecules [1,2]. These include a general mid-range correlation chart, a chart for aromatic absorptions, and a chart for carbonyl

Organic Analytical Reagents for the Determination of Inorganic Cations

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The table entitled Organic Analytical Reagents for the Determination of Inorganic Substances, by G. Ackermann, L. Sommer, and D. Thorburn Burns, has been revamped and considerably expanded for this edition. The many recent advancements in this area have

Photo-induced Surface Transformation of Silica Nanocomposites

June 22, 2012
Author(s)
Justin M. Gorham, Tinh Nguyen, Coralie Bernard, Deborah S. Jacobs, Richard D. Holbrook
The physicochemical, UV-induced surface modifications to silica nanoparticle (SiNP) - epoxy composites have been investigated. The silica nanocomposites (SiNCs) were prepared using a two-part epoxy system with 10 % mass fraction of SiNPs and exposed to

Preparation of Special Analytical Reagents

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
This listing of analytical reagents has been updated to include formulations based on more recent experience, and also safety notes. In the absence of specific cautions, the user must observe sound laboratory practice and housekeeping to avoid exposure and

Properties of Common Cross-Linked Silicone Stationary Phases

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
Modern gas chromatography is most often performed with high efficiency capillary (open tubular) columns coated with a cross linked polymeric stationary phase. We provide chromatographic data on the two most common cross-linked phases [1]. The retention

Properties of Important NMR Nuclei

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table lists the magnetic properties at higher field strengths required for choosing the nuclei to be used in NMR experiments [1-15]. The reader is referred to several excellent texts and the literature for guidelines in nucleus selection. For

Proton NMR Absorption of Major Chemical Families

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table gives the region of the expected nuclear magnetic resonance absorptions of hydrocarbon families. These absorptions are reported in the dimensionless units of parts per million (ppm) versus the standard compound tetramethylsilane (TMS

Solid-Phase Microextraction Sorbents

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
While trapping sorbents have been used for many years in headspace analysis (most commonly with gas chromatography), the modern techniques of solid phase microanalysis (SPME) are particularly applicable to survey analyses [1]. In the following tables, we

Standards for Laboratory Weights

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table provides a summary of the requirements for metric weights and mass standards commonly used in chemical analysis1-3. The actual specifications are under the jurisdiction of ASTM Committee E-41 on General Laboratory Apparatus and are the

TESTING LONG-WAVELENGTH ACOUSTIC FLOWMETER CONCEPTS FOR FLUE GAS FLOWS

June 22, 2012
Author(s)
Lee J. Gorny, Keith A. Gillis, Michael R. Moldover
As a part of NIST’s program to standardize measurements of greenhouse gas emissions, we are developing a long-wavelength acoustic flowmeter (LWAF) for accurate, economical measurements of exhaust flows from coal-burning power plants. Measurements of the

Wavelength-Wavenumber Conversion Table

June 22, 2012
Author(s)
Thomas J. Bruno, Paris D. Svoronos
The following table provides a conversion between wavelength and wavenumber units, for use in infrared spectrophotometry [1]. Since spectra are presented in different formats, this table is an aid in interpretation.

How nanorough is rough enough?

June 21, 2012
Author(s)
Konrad Rykaczewski, William A. Osborn, Jeff Chinn, Marlon L. Walker, John H. Scott, Wanda Jones, Chonglei Hao, Shuhuai Yao, Zuankai Wang
Surfaces which evince superhydrophobic properties during water condensation have a potential to dramatically enhance energy efficiency in power generation and desalination systems. Although various such surfaces have been reported, their development has

Hydrodynamic chromatography

June 21, 2012
Author(s)
Andre M. Striegel, Amandaa Brewer
Hydrodynamic chromatography (HDC) has experienced a resurgence in recent years for particle and polymer characterization due, principally, to its coupling to a multiplicity of physical detection methods. Coupled to light scattering (both multi-angle static
Displaying 22901 - 22925 of 73741
Was this page helpful?