Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 201 - 225 of 617

A novel measure and significance testing in data analysis of cell image segmentation

April 20, 2017
Author(s)
Jin Chu Wu, Michael W. Halter, Raghu N. Kacker, John T. Elliott, Anne L. Plant
… CIS algorithms taken from ImageJ. Further, the SE and 95% confidence interval (CI) of TER are computed based on the … between two CIS algorithms is also provided. Hence, the 95% CI error bars can be used to classify CIS algorithms. The …

Variability and bias assessment in breast ADC measurement across multiple systems

February 29, 2016
Author(s)
Kathryn E. Keenan, Sheye O. Aliu, Lisa J. Wilmes, David C. Newitt, Ella F. Jones, Wen Li, Michael A. Boss, Karl F. Stupic, Stephen E. Russek, Nola M. Hylton
… scannercoil-sequences ranged from low variability (0.47, 95% confidence interval [CI]: 0.22-1.00) to high variability (1.69, 95% CI: 0.17-17.26), depending on material, with the lowest …

Methylmercury inTtuna: Demonstrating Measurement Capabilities and Evaluating Comparability of Results Worldwide From the CCQM P-39 Comparison

October 12, 2021
Author(s)
C Quetel, J P. Snell, Y Aregbe, L Abranko, Z S. Jokai, C Brunori, R Morabito, W Hagan, S. Azemard, E Wyse, V Fajon, M. Horvat, M. Logar, O.F. X. Donard, E Krupp, J Entwisle, R Hearn, Michele M. Schantz, K Inagaki, A Takatsu, P Grinberg, S. N. Willie, H Hintelmann, E Bjorn, E Blanco Gonzalez, G Centineo, J Ignacio Garcia Alonso, A Sanz-Medel
… Metre Convention and 2 international organisations, and 8 expert laboratories selected outside CIPM have compared … 14 participants the average was 1.93 0.57 10 5 mol Kg-1 (95 % confidence) and the mixture mode median, calculated also … stated by the participants, was 1.967 0.204 10 5 mol Kg-1 (95 % confidence). Twelve of these results were regrouped …

High resolution X-ray transition-edge sensor cooled by tunnel junction refrigerators and operated above the transition temperature

April 21, 2008
Author(s)
Nathan A. Tomlin, Galen C. O\'Neil, James A. Beall, Gene C. Hilton, Kent D. Irwin, Daniel R. Schmidt, Leila R. Vale, Joel N. Ullom
We demonstrate cooling of an X-ray transition-edge sensor (TES) using solid-state refrigerators based on normal-metal / insulator / superconductor (NIS) tunnel junctions. We are able to operate the TES at a bath temperature of 260 mK, which is 75 mK above

The Free Energy Surface of Supercooled Water

December 1, 2000
Author(s)
A Scala, Francis W. Starr, E LaNave, H E. Stanley, F Sciortino
… predictions [Y. Rosenfeld and P. Tarazona, Mol. Phys. 95, 141 (1998)], and it to locate the position of a …

A Reference High-Pressure CH4 Adsorption Isotherm for Zeolite Y: Results of an Interlaboratory Study

September 11, 2020
Author(s)
Huong Giang T. Nguyen, Christopher M. Sims, Blaza Toman, Jarod C. Horn, Roger D. van Zee, Mathias Thommes, Riaz Ahmad, Joeri F. Denayer, Gino V. Baron, Emilio Napolitano, Marek Bielewski, Enzo Mangano, Stefano Brandani, Broom Darren, M.J. Benham, Anne Dailly, Frieder Dreisbach, Satyannarayana Edubilli, Sasidhar Gumma, Jens Mollmer, Marcus Lange, Mi Tian, Tim Mays, T. Shigeoka, S. Yamakita, M. Hakuman, Y. Nakada, K. Nakai, Junyoung Hwang, Ronny Pini, Huan Jiang, Armin Ebner, Marjorie Nicholson, James Ritter, Judit Farrando Perez, Carlos Cuadrado, Joaquin Silvestre Albero, Christos Tampaxis, Theodore Steriotis, Daniela Rimnacova, Martina Svabova, Maryna Vorokhta, Hai Wang, Eric Bovens, Nicolas Heymans, Guy de Weireld
… empirical reference equation was determined, along with a 95% uncertainty interval (Uk=2). By requiring participants to …

Uncertainty in RECIST as a measure of volume for lung nodules and liver malignoma

April 27, 2012
Author(s)
Zachary H. Levine, Adam L. Pintar, John G. Hagedorn, Charles D. Fenimore, Claus P. Heussel
… predicts volume to a factor of 17 or 10 respectively with 95 % confidence and that changes in volume are predicted only a little better: to within a factor of 8 for the liver data. Additionally, we show the RECIST …
Displaying 201 - 225 of 617
Was this page helpful?