Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 351 - 375 of 382

Refrigerant Flow Through Flexible Short-Tube Orifices

April 1, 2002
Author(s)
William V. Payne, Y C. Kim, Dennis L. O'Neal, Mohsen Farzad
… of 9860 kPa. Both short tubes had identical lengths (14.5 mm), entrance diameters (2.06 mm), and exit diameters (2.46 … which corresponded to saturated condensing temperatures of 29.4 to 54.4°C. Experimental results were presented as a …

An Octacalcium Phosphate Forming Cement

April 16, 2010
Author(s)
Milenko Markovic, Laurence C. Chow
… α TCP/DCPA molar ratio of 1/1 and distilled water or 0.5 mol/L phosphate aqueous solution (pH = 6.1 ± 0.1 ) as the … time was (30 ± 1) min for the CPC mixed with water and (5 ± 1) min for the CPC mixed with phosphate solution. … (41.44 ± 1.25) vol % after 1 d, respectively, (4.38 ± 0.29) MPa and (42.52 ± 2.15) vol % after 3 d, respectively, and …

Strong Calcium Phosphate Cement-Chitosan-Mesh Construct Containing Cell-Encapsulating Hydrogel Beads for Bone Tissue Engineering

April 25, 2006
Author(s)
Michael Weir, Hockin D. Xu, Carl G. Simon Jr.
… Absorbance at 450 nm (arbitrary units) (mean sd; n = 5) was (1.36 0.41) for cells inside conventional CPC, (1.29 0.24) for cells inside CPC-chitosan, and (0.73 0.22) for … with chitosan, 4.3 MPa with chitosan and one mesh, and 9.5 MPa with chitosan and three sheets of mesh on the specimen …

Reinforcement of a Self-Setting Calcium Phosphate Cement with Different Fibers

October 1, 2000
Author(s)
Hockin D. Xu, F Eichmiller, Anthony A. Giuseppetti
… from 3-200 mm, and fiber volume fraction ranged from 1.9-9.5%. The fibers were mixed with CPC paste and placed into … SD; n = 6) was (62 16) for aramid, (59 11) for carbon, (29 8) for E-glass, and (24 4) for polyglactin, with 5.7% volume fraction and 75 mm fiber length. In comparison, …

High Throughput Measurement of Peel of a Pressure Sensitive Adhesive

January 1, 2006
Author(s)
P M. McGuiggan, James J. Filliben
The peel force of a pressure sensitive adhesive (PSA) tape is measured on a surface that varied linearly in temperature. As the tape is peeled from the surface, the adhesive is peeled from a surface at a different temperature. The temperature can be

Chemical and Physical Changes During Seawater Flow through Intact Dunite Cores: An Experimental study at 150-200 degC

October 1, 2017
Author(s)
Andrew J. Luhmann, Benjamin M. Tutolo, Brian C. Bagley, David F. Mildner, Peter P. Scheuermann, Joshua M. Feinberg, Konstantin Ignatyev, Jr. Seyfried
Two flow-through experiments were conducted to assess serpentinization of intact dunite cores. Permeability and fluid chemistry indicate significantly more reaction during the second experiment at 200 °C than the first experiment at 150°C. Permeability

Study of Isochoric Specific Heat Capacity Measurements for Liquid Isobutane

October 12, 2021
Author(s)
Hiroyuki Miyamoto, Hiroshi Kitajima, Noboru Kagawa, Joe W. Magee, Seizo Tsuruno, Koichi Watanabe
… between the cells was maintained within plus or minus} 5 mK. Each cell temperature was measured with a platinum … range of temperatures 227 K ¿ 417 K and pressures 3 MPa ¿ 29 MPa (Figure 3). Figure 4 shows comparisons of the 119 …

AN INFORMATION MODELING METHODOLOGY FOR STANDARDS

August 31, 2011
Author(s)
Anantha Narayanan Narayanan, Jae H. Lee, Paul W. Witherell, Prabir Sarkar, Sudarsan Rachuri
… in Engineering Conference IDETC/CIE 2011 August 29-31, 2011, Washington, DC, USA …
Displaying 351 - 375 of 382
Was this page helpful?