Experiment Name | Plot of Heat Release Rate | Ignition Photo | Date/Time | Project Sort descending | Specimen | Fuel Type | Total Heat Released (MJ) | Peak HRR (kW) |
---|---|---|---|---|---|---|---|---|
D2 | Chair mockup | Composite | 268
|
498
|
||||
BSEE_Test_001 | gravel burner | Methane | 18.4
|
39.1
|
||||
BSEE_Test_002 | gravel burner | Methane | 2.24
|
44.0
|
||||
Methanol_1m_Pool_R1 | Characteristics of a 1 m Methanol Pool Fire | 1 m diameter pool burner | Methanol | 753
|
282
|
|||
Methanol_1m_Pool_R2 | Characteristics of a 1 m Methanol Pool Fire | 1 m diameter pool burner | Methanol | 1,243
|
279
|
|||
NGCal15m20MWburner | Cross Laminated Timber Compartments | tube gas burner | Natural Gas | 28,734
|
23,535
|
|||
NGCal15m20MWburner2 | Cross Laminated Timber Compartments | tube gas burner | Natural Gas | 22,938
|
22,018
|
|||
CLT_Room_Test_1-1 | Cross Laminated Timber Compartments | furnished studio apartment | Cellulose, Plastic | 17,883
|
9,487
|
|||
CLT_Room_Test_1-2 | Cross Laminated Timber Compartments | furnished studio apartment | Cellulose, Plastic | 18,541
|
12,451
|
|||
CLT_Room_Test_1-3 | Cross Laminated Timber Compartments | furnished studio apartment, CLT wall | Cellulose, Plastic | 32,448
|
14,171
|
|||
CLT_Room_Test_1-4 | Cross Laminated Timber Compartments | furnished studio apartment, CLT ceiling | Cellulose, Plastic | 35,941
|
13,114
|
|||
CLT_Room_Test_1-5 | Cross Laminated Timber Compartments | furnished studio apartment, CLT wall | Cellulose, Plastic | 53,580
|
10,372
|
|||
CLT_Room_Test_1-6 | Cross Laminated Timber Compartments | furnished studio apartment, CLT wall and ceiling | Cellulose, Plastic | 78,200
|
12,910
|
|||
CornerTest1 | Cross Laminated Timber Compartments | room corner mockup | Cellulose, Plastic | 1,522
|
1,624
|
|||
CornerTest2 | Cross Laminated Timber Compartments | room corner mockup | Cellulose, Plastic | 1,572
|
2,083
|
|||
WateredTree3 | Dry Tree Fire Hazard | watered pine tree, upholstered chair and shelf in room corner | Cellulose, Plastic | below detection limit
|
6.7
|
|||
Dry_Pine_Tree | Dry Tree Fire Hazard | dry pine tree, upholstered chair and shelf in room corner | Cellulose, Plastic | 938
|
7,362
|
|||
Propane Burner Check | Fire Barriers in Full-Scale Chair Mock-ups | gas tube burner | Propane | 3.22
|
24.3
|
|||
B4-1 | Fire Barriers in Full-Scale Chair Mock-ups | upholstered chair mockup | Polyurethane Foam | 310
|
2,084
|
|||
C0-1 | Fire Barriers in Full-Scale Chair Mock-ups | upholstered chair mockup | Polyurethane Foam | 315
|
2,834
|
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314