Search Publications by: W.Bertrand (Randy) Doriese ()

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 126 - 150 of 166

A TDMA Hybrid SQUID Multiplexer

January 25, 2008
Author(s)
Carl D. Reintsema, James A. Beall, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Kent D. Irwin, Dan Schmidt, Joel Ullom, Leila R. Vale, Yizi Xu
We have developed a multiplexed read-out for transition edge sensors based on a hybrid time- and frequency-domain basis set, similar to that used in time-division multiple-access (TDMA) mobile phones. The hybrid basis set uses bandwidth more efficiently

Large array of multiplexed gamma-ray microcalorimeters for nuclear-materials analysis

January 24, 2008
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Michael W. Rabin, Minesh K. Bacrania, Stephen Lamont, Andrew Hoover, Clifford R. Rudy, Duc Vo, C. K. Stahle, Kevin R. Boyce, Larry E. Brown, Jonathan M. King, F. S. Porter
We are developing a gamma-ray spectrometer for the analysis of nuclear materials based on an array of superconducting transition-edge-sensor microcalorimeters. The instrument includes eight columns of time-division-SQUID multiplexing circuitry capable of

Multiplexed microcalorimeter arrays for precision measurements from microwave to gamma-ray wavelengths

August 21, 2007
Author(s)
Joel Ullom, W.Bertrand (Randy) Doriese, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, Terrence J. Jach, John Mates, Nathan A. Tomlin, Galen O'Neil, Carl D. Reintsema, Nicholas Ritchie, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Andrew Hoover, Clifford R. Rudy, Derek Tournear, Duc Vo, Michael W. Rabin
Cryogenic microcalorimeters are a promising technology for ultrasensitive measurements of electromagnetic radiation from microwave to gamma-ray wavelengths. Cryogenic microcalorimeters derive their exquisite sensitivity from the minimal thermal noise at

A 14-pixel, multiplexed array of gamma-ray microcalorimeters with 47 eV energy resolution at 103 keV

May 9, 2007
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Leila R. Vale, Yizi Xu, Barry L. Zink, Andrew Hoover, Michael W. Rabin, Clifford R. Rudy, Duc Vo
We present a prototype for a high-energy-resolution, high-count-rate, gamma-ray spectrometer intended for nuclear forensics and international nuclear safeguards. The prototype spectrometer is an array of 14 transition-edge-sensor microcalorimeters with an

Demonstration and modeling of an array-compatible TES microcalorimeter gamma-ray detector with 42 eV energy resolution at 103 keV

September 20, 2006
Author(s)
Barry L. Zink, Joel Ullom, James A. Beall, Kent D. Irwin, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Carl D. Reintsema, Leila R. Vale
We describe a microcalorimeter gamma-ray detector with measured energy resolution of 42 eV full width at half maximum for 103 keV photons. This detector consists of a thermally isolated superconducting transition-edge thermometer and a superconducting bulk

Optimization of Transition-Edge Calorimeter Performance

April 15, 2006
Author(s)
Joel N. Ullom, James A. Beall, William B. Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Kent D. Irwin, Galen C. O'Neil, Carl D. Reintsema, Leila R. Vale, Barry L. Zink
Calorimeters that exploit the superconducting-to-normal transition are used to detect individual photons from near-infrared to γ-ray wavelengths. Across this wide range, absorption efficiency, speed, and energy resolution are key performance parameters

Microwave SQUID multiplexers for low-temperature detectors

January 10, 2006
Author(s)
Kent D. Irwin, James A. Beall, W.Bertrand (Randy) Doriese, William Duncan, Gene C. Hilton, John Mates, Carl D. Reintsema, Dan Schmidt, Joel Ullom, Leila R. Vale, Barry L. Zink, Konrad Lehnert
We report on the development of a SQUID multiplexer operated at microwave frequencies. This multiplexer can accommodate any detector that can be read out with SQUIDs, including transition-edge sensors, magnetic calorimeters, and superconductor-insulator

Toward kilopixel arrays: 3.8 eV microcalorimeter resolution in 8-channel SQUIDmultiplexer

January 10, 2006
Author(s)
W.Bertrand (Randy) Doriese, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Kent D. Irwin, Carl D. Reintsema, Joel Ullom, Leila R. Vale, Yizi Xu
Over the past several years, NIST has developed a SQUID time-division multiplexer (TDM) to read out large arrays of transition-edge sensors (TESs). The NIST TDM architecture has been successful in a number of submillimeterand millimeter-wave applications

Fabrication of Prototype Imaging Arrays for SCUBA-2

January 4, 2006
Author(s)
Gene C. Hilton, James A. Beall, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Kent D. Irwin, Carl D. Reintsema, Joel Ullom, Leila R. Vale, Yizi Xu, Barry L. Zink, William Parkes, Andrew S. Bunting, Camilla Dunare, Alan Gundlach, T. Stevenson, Anthony Walton, Eric Schulte, Elizabeth Corrales, Joseph P. Sienicki, Dan Bintley, Peter Ade, Rashmi Sudiwala, Adam L. Woodcraft, Mark Halpern, Wayne Holland, Damian Audley, Michael MacIntosh
Prototype imaging sub-arrays for SCUBA-2 (the Sub-millimeter Common-User Bolometer Array) have been fabricated and tested. The pixel count (1280) of these wafer-scale imagers are significantly larger than any other low-temperature detectors produced to

Optimized Transition-Edge X-ray Microcalorimeter with 2.4 eV Energy Resolution at 5.9 keV

November 1, 2005
Author(s)
Joel Ullom, James A. Beall, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Kent D. Irwin, Carl D. Reintsema, Leila R. Vale
We present measurements from a series of transition- edge x-ray microcalorimeters designed for optimal energy resolution. We used the geometry of the sensors to control their heat capacity and employed additional normal metal features and a perpendicular

Time-division multiplexing of high-resolution TES X-ray microcalotimeters: Four pixels and beyond

November 15, 2004
Author(s)
W.Bertrand (Randy) Doriese, James A. Beall, Steven Deiker, William Duncan, S. L. Ferreira, Gene C. Hilton, Kent D. Irwin, Carl D. Reintsema, Joel Ullom, Leila R. Vale, Yizi Xu
We present experimental results from a four-pixel array of transition-edge-sensor, x-ray microcalorimeters read out through a single amplifier channel via a time-division superconducting quantum interference device multiplexer. We map the dependence of the

Superconducting transition edge sensor using dilute AlMn alloys

July 6, 2004
Author(s)
Steven Deiker, William B. Doriese, Gene C. Hilton, Kent D. Irwin, William H. Rippard, Joel N. Ullom, Leila R. Vale, Steve T. Ruggiero, Anthony Williams, B. Young
We have fabricated a bolometer using a transition-edge sensor (TES) made of Al doped with Mn to suppress the superconducting critical temperature !Tc" of Al from #1 K to #100 mK. The resulting detector exhibits low-frequency noise consistent with theory

Characterization and Reduction of Unexplained Noise in Superconducting Transition-Edge Sensors

May 7, 2004
Author(s)
Joel N. Ullom, William B. Doriese, Gene C. Hilton, James A. Beall, Steven Deiker, William Duncan, S. L. Ferreira, Kent D. Irwin, Carl D. Reintsema, Leila R. Vale
The noise in superconducting Transition-Edge Sensors (TESs) commonly exceeds simple theoretical predictions. The reason for this discrepancy is presently unexplained. We have measured the amplitude and frequency dependence of the noise in TES sensors with