Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Thomas R. Gentile (Assoc)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 51 - 75 of 202

Friedel-like Oscillations from Interstitial Iron in Superconducting Fe 1+y Te 0.62 Se 0.38

March 7, 2012
Author(s)
V. Thampy, J. Kang, Jose Rodriguez Rivera, W. Bao, A. T. Savici, J. Hu, T. J. Liu, B. Qian, D. Fobes, Z. Q. Mao, C. B. Fu, Wangchun Chen, Q. Ye, Ross Erwin, Thomas R. Gentile, Z. Tesanovic, Collin L. Broholm
Using polarized and unpolarized neutron scattering we show that interstital Fe in superconducting Fe 1=yTe 1-xSe x induces a magnetic Friedel-like oscillation that idffracts at Q = (1⁄20) and involves greater than}50 neighboring Fe sites. The interstitial

Magnetic field effects on large area avalanche photodiodes at cryogenic temperatures

August 30, 2011
Author(s)
Thomas R. Gentile, C. D. Bass, Jeffrey S. Nico, H Breuer, R Farrell
We present results for detection of X-rays by large area avalanche photodiodes (APDs) in strong magnetic fields and at cryogenic temperatures. Whereas at room temperature we observe essentially no effects on the response, at cryogenic temperature we

Polarized He-3 cell development and application at NIST

June 14, 2011
Author(s)
Thomas R. Gentile, WangChun Chen, Changbo Fu, Shannon Watson, Gordon L. Jones, J. W. McIver, D. R. Rich
Over a period of well over a decade, a large number and variety of polarized 3He cells for neutron applications have been developed and tested at the U.S. National Institute of Standards and Technology (NIST). These cells have primarily been employed for

Neutron Charged Radius and the Neutron Electric Form Factor

May 2, 2011
Author(s)
Thomas R. Gentile, C.B. Crawford
For nearly forty years, the Galster parametrization has successfully fit existing data for the neutron electric form factor, GEn,vs. the square of the four-momentum transfer, Q^2. Typically this parametrization is constrained to be consistent with

A Measurement of the Parity Violating Gamma-ray Asymmetry in the Capture of Polarized Cold Neutrons on Protons

January 31, 2011
Author(s)
Thomas R. Gentile, M T. Gericke, R. Alarcon, S. Balascuta, L. Barron, C S. Blessinger, J D. Bowman, R D. Carlini, W.C. Chen, T E. Chupp, C. Crawford, S. Covrig, M Dabaghyan, N. Formin, S J. Freedman, R C. Gillis, G L. Greene, F W. Hersman, T. Ino, Gordon L. Jones, B Lauss, M Leuschner, W R. Lozowski, R Mahurin, Y Masuda, J Mei, G S. Mitchell, S Muto, H Nann, S A. Page, S I. Penttila, W D. Ramsay, A. Salas-Bacci, S Santra, Katelynn A. Sharma, P.-N. Seo, E I. Sharapov, T B. Smith, William M. Snow, W S. Wilburn, V Yuan
The NPDGamma collaboration reports results from the first phase of a measurement of the parity violating up-down asymmetry A_gamma with respect to the neutron spin direction of gamma-rays emitted in the reaction n + p -> d + gamma using the capture of

In-situ Polarized He3-Based Neutron Polarization Analyzer for SNS Magnetism Reflectometer

January 31, 2011
Author(s)
W-T Lee, X Tong, J. Pierce, M. Fleenor, A. Ismaili, JL Robertson, Wangchun Chen, Thomas R. Gentile, A. Hailemariam, R J. Goyette, A. Parizzi, V Lauter, F. Klose, H. Kaiser, C. Lavelle, DV Baxter, G L. Jones, J. Wexler, L. McCollum
We report here the construction and neutron transmission test results of an in-situ polarized 3He-based neutron polarization analyzer system for the Magnetism Reflectometer at the Spallation Neutron Source, Oak Ridge National Laboratory. The analyzer uses

A Wide Angle Neutron Spin Filter System Using Polarized 3He

October 16, 2010
Author(s)
Changbo Fu, Thomas R. Gentile, Wangchun Chen, Ross Erwin, Shannon M. Watson, Collin L. Broholm, Jose Rodriguez Rivera, Julia Scherschligt, G L. Jones
Polarized 3He neutron spin filters can operate over a wide neutron energy range and provide a large angular acceptance. A compact 3He neutron spin filter system has been developed for the Multi Axis Crystal Spectrometer at the NIST Center for Neutron

Internal quantum efficiency modeling of silicon photodiodes

April 1, 2010
Author(s)
Thomas R. Gentile, Steven W. Brown, Keith R. Lykke, Ping-Shine Shaw, John T. Woodward IV
Results are presented for modeling of the internal quantum efficiency (IQE) of silicon photodiodes in the 400 nm to 900 nm wavelength range. The IQE data are based on measurements of the external quantum efficiencies of three transmission trap detectors

Effects of High Flux Neutron Beams on He-3 cells Polarized In-situ with Spin-exchange Optical Pumping

December 30, 2009
Author(s)
E Babcock, Stephen Boag, Maria Becker, W.C. Chen, T E. Chupp, Thomas R. Gentile, G L. Jones, A K. Petukhov, Torsten Soldner, T G. Walker
Polarized 3He produced by spin-exchange optical pumping (SEOP) has potential as a neutron spin filter for polarization and polarization analysis in many neutron scattering and neutron particle physics applications. The advantage of the SEOP method is its
Was this page helpful?