Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1926 - 1950 of 7702

Suppression Limits of Low Strain Rate Non-Premixed Flames

January 5, 2011
Author(s)
Matthew F. Bundy, Anthony P. Hamins
The suppression of low strain rate non-premixed flames was investigated experimentally in a counterflow configuration through the development of a methodology that allows establishment of laminar flames free from conductive heat losses. The method allows

Clean agent suppression of energized electrical equipment fires

January 3, 2011
Author(s)
Gregory T. Linteris
The NFPA 2001 standard on the use of clean agents for the suppression of fires arose from the phase-out of Halon 1301. Standard methods exists for specifying the amount of clean agent required for Class A and Class B fires, but the recommendation for Class

Effects of Fuel Location and Distribution on Full-Scale Underventilated Compartment Fires

January 3, 2011
Author(s)
Andrew J. Lock, Cheolhong Hwang, Matthew F. Bundy, Erik L. Johnsson, Gwon H. Ko
Experimental and numerical studies were conducted to investigate the effect of fuel location and distribution on full-scale underventilated compartment fires in an ISO 9705 room. Heptane fuel was burned in three different fuel distributions: single

Modeling Smoldering Fires using the Computer Model CONTAM

December 1, 2010
Author(s)
William D. Davis
The computer model CONTAM was used to simulate the spread of smoke in a house with a working furnace during smoldering fires. Three smoldering experiments from a study on detector sensitivity and siting requirements conducted in 1975 using a two story

Fire Suppression

November 16, 2010
Author(s)
Cary Presser, Jiann C. Yang
Water sprinkler sprays (with relatively large droplet sizes) in residential and commercials structures are probably the most well known application of sprays in fire suppression. In more recent years, water mists (characterized by reduced droplet sizes

PERFORMANCE ASSESSMENTS INSIGHTS ON THE USE OF CEMENTS IN WASTE MANAGEMENT

November 7, 2010
Author(s)
David W. Esh, Jacob Philip, Kenneth A. Snyder
The use of cementitious materials has been proposed in a variety of waste management systems because these materials can have a variety of desirable performance characteristics: hydraulic isolation, chemical isolation, structural stability. Cementitious

A Review of Building Evacuation Models, 2nd Edition

November 1, 2010
Author(s)
Erica D. Kuligowski, Richard D. Peacock, Bryan L. Hoskins
Evacuation calculations are increasingly becoming a part of performance-based analyses to assess the level of life safety provided in buildings. In some cases, engineers are using back-of-the-envelope (hand) calculations to assess life safety, and in

Technical Study of the Sofa Super Store Fire- South Carolina, June 18, 2007 Volume I ***DRAFT FOR PUBLIC COMMENT*** (for final version, see NIST SP 1118, March 2011)

October 28, 2010
Author(s)
Nelson P. Bryner, Anthony D. Putorti Jr., Stephen P. Fuss, Bryan W. Klein
A fire occurred on the evening of June 18, 2007, in the Sofa Super Store in Charleston, SC. NIST analyzed the fire ground, consulted with other experts, and performed computer simulations of fire growth alternatives. Based on these analyses, the following
Displaying 1926 - 1950 of 7702