Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1801 - 1825 of 4041

Single bead detection with a NMR micro capillary probe

December 6, 2012
Author(s)
Yoshihiro Nakashima, Michael A. Boss, Stephen E. Russek, John M. Moreland
We have developed a nuclear magnetic resonance (NMR) microcapillary probe for the detection of single magnetic microbeads. The geometry of the probe has been optimized so that the signal from the background water has a similar magnitude compared to the

Broad-band frequency references in the near-infrared: accurate dual comb spectroscopy of methane and acetylene

December 1, 2012
Author(s)
Alexander M. Zolot, Fabrizio R. Giorgetta, Esther Baumann, William C. Swann, Ian R. Coddington, Nathan R. Newbury
The Doppler-limited spectra of methane between 176 THz and 184 THz (5870-6130 cm −1) and acetylene between 193 THz and 199 THz (6430-6630 cm −1) are acquired via comb-tooth resolved dual comb spectroscopy with frequency accuracy traceable to atomic

Long-term stability of metal-envelope enclosed ionization gauges

December 1, 2012
Author(s)
James A. Fedchak, Dana R. Defibaugh
Ionization vacuum gauges are used as secondary standards by calibration laboratories and as transfer standards in intercomparisons among metrology laboratories. A quantitative measurement of gauge stability with respect to the gauge calibration factor is

Immobilization of Proteins on Carboxylic Acid-Functionalized Nanopatterns

November 28, 2012
Author(s)
John Peter Ngunjiri, Daniel J. Stark, Tian Tian, Kimberly Briggman, Jayne C. Garno
The immobilization of proteins on nanopatterned surfaces was investigated using in situ atomic force microscopy (AFM) and ex situ infrared reflectance-absorption spectroscopy (IRAS). The AFM-based lithography technique of nanografting provided control of

Absolute line intensities for ethylene from 1800 to 2350 cm-1.

November 17, 2012
Author(s)
Walter J. Lafferty, Jean-Marie Flaud, A. Ben Hassen, F. K. Kwabia Tchana, X Landsheere, H Aroui
Fourteen Fourier transform spectra of ethylene (C2H4) have been recorded in the 1800-2350 spectral domain with different path-lengths and pressures and used to derive individual line intensities for lines belonging to the ν7 + ν8, ν4 + ν8 , ν6 + ν10, ν6 +

High-resolution infrared studies of the V10, V11, V14, and V18 levels of [1.1.1] propellane

November 15, 2012
Author(s)
Robynne Kirkpatrick, Tony Masiello, Mathew A. Martin, Joseph W. Nibler, Arthur Maki, Alfons Weber, Thomas A. Blake
This paper is a continuation of earlier work for which the high resolution infrared spectrum of [1.1.1]propellane was measured and its k and l structure resolved for the first time. Here we present results from an analysis of more than 16,000 transitions

East versus West: Organic Contaminant Differences in Brown Pelican (Pelecanus occidentalis) Eggs from South Carolina, USA and the Gulf of California, Mexico

November 1, 2012
Author(s)
Stacy S. Schuur, Daniel W. Anderson, Patrick G. Jodice, Joyce E. Stuckey
Brown pelicans (Pelecanus occidentalis) were listed as endangered in the United States in 1970, largely due to reproductive failure and mortality caused by organochlorine contaminants, such as DDT. The southeast population, P.o. carolinensis, was delisted
Displaying 1801 - 1825 of 4041
Was this page helpful?