Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1126 - 1150 of 2714

Measurement Science for 6DOF object pose ground truth

June 28, 2013
Author(s)
Roger D. Eastman, Jeremy Marvel, Joseph Falco, Tsai H. Hong
Users of perception systems in industrial manufacturing applications need standardized, third party ground truth procedures to validate system performance before deployment. Many manufacturing robotic applications require parts and assemblies to be

NIST Micronutrients Measurement Quality Assurance Program Summer 2001 Comparability Studies: Results for Round Robin L Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 15 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Katherine E. Sharpless, Jeanice M. Brown Thomas, Sam A. Margolis
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Summer 2002 Comparability Studies: Results for Round Robin LII Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 17 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Katherine E. Sharpless, Margaret C. Kline, Jeanice M. Brown Thomas, Sam A. Margolis
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Summer 2003 Comparability Studies: Results for Round Robin LIV Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 19 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Katherine E. Sharpless, Jeanice M. Brown Thomas
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Summer 2004 Comparability Studies: Results for Round Robin LVI Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 21 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Jeanice M. Brown Thomas
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Summer 2005 Comparability Studies: Results for Round Robin LVIII Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 23 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Jeanice M. Brown Thomas
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Summer 2006 Comparability Studies: Results for Round Robin LX Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 25 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Jeanice M. Brown Thomas
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Winter 2002 Comparability Studies: Results for Round Robin LI Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 16 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Katherine E. Sharpless, Jeanice M. Brown Thomas, Sam A. Margolis
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Winter 2003 Comparability Studies: Results for Round Robin LIII Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 18 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Katherine E. Sharpless, Jeanice M. Brown Thomas
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Winter 2004 Comparability Studies: Results for Round Robin LV Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 20 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Jeanice M. Brown Thomas
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Winter 2005 Comparability Studies: Results for Round Robin LVII Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 22 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Jeanice M. Brown Thomas
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Winter 2006 Comparability Studies: Results for Round Robin LIX Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 24 Ascorbic Acid in Human Serum

June 27, 2013
Author(s)
David L. Duewer, Jeanice M. Brown Thomas
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

On the Field Evaporation Behavior of c-axis GaN Nanowires in Laser-Pulsed Atom Probe Tomography

June 26, 2013
Author(s)
Matthew D. Brubaker, Kristine A. Bertness, Norman A. Sanford, Brian Gorman, David R. Diercks, R Kirchofer
GaN has seen use in many applications such as photovoltaics, blue and ultraviolet lasers, and light-emitting diodes with additional research into expanded and new applications. GaN in the form of nanowires present additional possibilities due to their high

Evaluation of dome-input geometry for pyroelectric detectors

June 24, 2013
Author(s)
Jinan Zeng, Leonard M. Hanssen, George P. Eppeldauer
Dome-input pyroelectric radiometers with different black coatings were developed to extend the spectral responsivity scale from near infrared (NIR) to 20 μm. The reflective dome with shiny gold-coating has been known to be an efficient light trap to

Cubic Silsesquioxanes as Tunable High Performance Coating Materials

June 19, 2013
Author(s)
Christopher Soles, Hyun W. Ro, Aaron Forster, Dave J. Krug, Vera Popova, Richard M. Laine
In this manuscript a series of cubic silsequioxane monomers with their eight vertices functionalized with different organic ligands terminated with triethoxysilane groups were acid hydrolyzed, spin cast into thin films, and then vitrified into hard

Radio-Frequency and DC Electrical Characterization on a Modular MEMS Mechanical Test Platform for Nanomaterials

June 16, 2013
Author(s)
J. J. Brown, Thomas Mitchell (Mitch) Wallis, Pavel Kabos, Kristine A. Bertness, Norman Sanford, Victor Bright
In order to enable radio frequency (RF) data collection from a micromechanical system designed to strain nanomaterials, a coplanar electrical waveguide has been integrated with an actuated microscale stage. RF (100 MHz to 20 GHz) admittance measurements

The Effect of Turbulence on a Multi-Hole Pitot Calibration

June 10, 2013
Author(s)
Christopher J. Crowley, Iosif I. Shinder, Michael R. Moldover
Abstract- Accurate calibrations of multi-hole Pitot tubes require thousands of measurements spanning ranges of the fluid’s velocity, and the pitch and yaw angles. When calibrating a commercially-manufactured multi-hole Pitot tube in NIST’s low-turbulence

SHREC13 Track: Large Scale Sketch-Based 3D Shape Retrieval

June 6, 2013
Author(s)
Afzal A. Godil, Bo Li , Yijuan Lu, Tobias Schreck
Sketch-based 3D shape retrieval has become an important research topic in content-based 3D object retrieval. The aim of this track is to measure and compare the performance of sketch-based 3D shape retrieval methods based on a large scale hand-drawn sketch
Displaying 1126 - 1150 of 2714
Was this page helpful?