Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 526 - 550 of 583

Structural and thermoelectric properties of Bi2Sr2Co2Oy thin films on LaAlO3 (100) and fused silica substrates

January 12, 2009
Author(s)
Winnie K. Wong-Ng, Mark D. Vaudin, Shufang Wang, L Venimadhav, Shengming Guo, Ke Chen, Qi Li, A Soukiassian, D.G. Schlom, X.Q. Pan, D.G. Cahill, X. X. Xi
We have grown Bi2Sr2Co2Oy thin films on LaAlO3 (100) and fused silica substrates by pulsed laser deposition. The films on LaAlO3 are c-axis oriented and partially in-plane aligned with multiple domains while the films on fused silica are preferred c-axis

Local Structure of Cu in Cs8Na16Cu5Ge131 Type II Clathrate

January 8, 2009
Author(s)
Winnie K. Wong-Ng, Azzam Mansour, Matthew Beekman, George S. Nolas
We have used X-ray absorption spectroscopy (XAS) to investigate the local structure of Cu and Ge in the Cs8Na16Cu5Ge131 type II clathrate. We show that the local structure parameters, coordination number, and distances for Ge are consistent with those

Multichannel Decomposition and Isomerization of Octyl Radicals

October 9, 2008
Author(s)
Wing Tsang, William S. McGivern, Jeffrey A. Manion
The thermal cracking patterns from the decomposition and isomerization of octyl-1 radicals have been determined from the pyrolysis of n-octyl iodide in single pulse shock tube experiments at temperatures in the 850-1000 K range and pressures near 2 bar

Natural Gas Flow Calibration Service

August 1, 2008
Author(s)
Aaron Johnson
This document describes NIST's high pressure natural gas flow calibration service (NGFCS). Flow calibrations are conducted offsite at the Colorado Experimental Engineering Station Incorporated (CEESI) in Garner, Iowa. A parallel array of nine turbine meter

Synthesis and Single-Crystal X-Ray Diffraction Studies of New Framework Substituted Type II Clathrates, Cs 8 Na 16 Ag x Ge 136-x (x 7)

April 13, 2007
Author(s)
Matthew Beekman, Winnie Wong-Ng, James A. Kaduk, Alexander J. Shapiro, George S. Nolas
New inorganic type II clathrates with Ag atoms substituting for framework Ge atoms, Cs8Na16AgxGe136-x (x = 0, 5.9, and 6.7), have been synthesized by reaction of the pure elements at high temperature. Structural refinements have been performed using single

A High-Throughput Thermoelectric Power-Factor Screening Tool for Rapid Construction of Thermoelectric Property Diagrams

January 23, 2007
Author(s)
Makoto Otani, Nathan Lowhorn, Peter K. Schenck, Winnie K. Wong-Ng, Martin L. Green, K Itaka, H Koinuma
We have developed a high throughput screening tool that maps out thermoelectric power factors of combinatorial composition-spread film libraries. The screening tool allows us to measure the electrical conductivity and Seebeck coefficient of over 1000

Combined NMR and XAS Study on Local Environments and Electronic Structures of the Electrochemically Li-Ion Deintercalated Li1-xCo1/3Ni1/3Mn1/302 Electrode System

January 1, 2004
Author(s)
W S. Yoon, C P. Grey, Mahalingam Balasubramanian, Xiao-Qing Yang, Daniel A. Fischer, James McBreen
Combined 6Li MAS NMR, in-situ metal K-edge (hard) XAS, and O K-edge (soft) XAS have been carried out during the first charging process for the layered Li1-xCo1/3Ni1/3Mn1/3O2 cathode material. The 6Li MAS NMR results showed the prescence of Li in the Ni2+

Compact Photoconductive-based Sampling System with Electronic Sampling Delay

May 1, 2000
Author(s)
W. L. Cao, M. Du, C G. Lee, Nicholas Paulter
As electronic signals move to higher frequencies and wider bandwidths, there is need for new methods of measuring these bandwidths, there is need for new methods of measuring these high frequency/high speed (tens of Hgz and or high bit rate (tens of GBs

Improved Time-Base for Waveform Parameter Estimation

May 1, 2000
Author(s)
Bryan C. Waltrip, Owen B. Laug, Gerard N. Stenbakken
An improved gated-oscillator time-base and associated auto-calibration algorithm for use in a high-accuracy sampling waveform acquistion system are described. The time-base architecture consists of a stable 100 MHz gated-oscillator, 24-bit counter chain

Nonrandom Quantization Errors in Timebases

May 1, 2000
Author(s)
Gerard N. Stenbakken, D. Liu, J. A. Starzyk, Bryan C. Waltrip
Timebase distortion causes nonlinear distortion of waveforms measured by sampling instruments. When such instruments are used to measure the rms amplitude of the sampled waveforms, such distortions result in errors in the measured rms values. This paper

A Wide Bandwidth Printed Wiring Board Transmission Line Probe

March 1, 1999
Author(s)
Nicholas Paulter, Jon R. Pratt
An inexpensive, wide bandwidth, high cycle 50 ω probe is described for making electrical contact to printed wiring board planar transmission lines. The electrical transfer function of the probe and its contact repeatability are presented.
Displaying 526 - 550 of 583
Was this page helpful?