Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 276 - 300 of 1314

Insulator-quantum Hall transition in monolayer epitaxial graphene

July 22, 2016
Author(s)
Lung-I Huang, Yanfei Yang, Randolph Elmquist, Shun-Tsung Lo, Fan-Hung H. Liu, Chi-Te Laing
We report on magneto-transport measurements on low-density, large-area monolayer epitaxial graphene devices grown on SiC. We observe temperature (T)-independent crossing points in the longitudinal resistivity (rho)sub(xx), which are signatures of the

MPInterfaces: A Materials Project based Python Tool for a High Throughput Computational Screening of Interfacial Systems

May 31, 2016
Author(s)
Arunima Singh, Kiran Mathew, Joshua Grabriel, Kamal Choudhary, Susan B. Sinnott, Albert Davydov, Francesca M. Tavazza, Richard G. Hennig
A Materials Project based open-source python tool, MPInterfaces, has been developed to automate the high throughput computational screening and study of interfacial systems. The framework encompasses creation and manipulation of interface structures for

Verification of a Foundry-Developed Transistor Model with Measurement Uncertainty

May 26, 2016
Author(s)
Dylan Williams, Richard Chamberlin, Wei Zhao, Jerome Cheron, Urteaga Miguel
We verify a foundry model for state-of-the-art 250 nm heterojunction bipolar transistors with large-signal measurements. We demonstrate the propagation of correlated measurement uncertainties through the verification process, and use them to quantify the

Testing of Cementitious Materials Using a Dynamic MEMS Micro Rheometer

May 17, 2016
Author(s)
Yong Sik Kim, Nicholas G. Dagalakis, Chiara C. Ferraris, Nicos Martys
Incompatibility of cementitious materials with admixtures often requires time consuming testing. Usually, several mixtures need to be prepared either using concrete or paste to determine the optimum high range water reducer dosage (HRWRA) and type. The

Vibrational Modes of Multilayered Ceramic Capacitors

April 28, 2016
Author(s)
Kirsten L. Peterson, Ward L. Johnson, Sudook A. Kim, Paul R. Heyliger
Micron-scale spacing of interleaved electrodes and high-dielectric ceramics in multilayer ceramic capacitors (MLCCs) provide exceptionally high capacitances in small volumes. This has led to MLCCs being the preferred type of capacitor in a wide range of

Public Safety Analytics R&D Roadmap

April 19, 2016
Author(s)
Tracy A. McElvaney, Ryan Felts, Marc Leh
The public safety community is in a period of great transition. Over the next 20 years, technology advancements will increase accessibility of data/video applications to public safety, and allow for the eventual migration of voice communications from

Surface conductance of graphene from non-contact resonant cavity

March 15, 2016
Author(s)
Jan Obrzut, Caglar Dogu Emiroglu, Oleg A. Kirillov, Yanfei Yang, Randolph E. Elmquist
A method is established to reliably determine surface conductance of single-layer or multi-layer atomically thin nano-carbon graphene structures. These can be synthesized by chemical vapor deposition (CVD), epitaxial growth on silicon carbide (SiC)

The Structural Origin of Electron Injection Enhancements with Fulleropyrrolidine Interlayers

February 25, 2016
Author(s)
Lee J. Richter, Hyunbok Lee, Christopher McNeil, Eliot Gann, Lars Thomsen, S. Park, J. Jeong, Z. A. Page, Egle Puodziukynaite, Todd Emrick, Alejandro Briseno, John C. Stephenson, Dean M. DeLongchamp
Market demand for ubiquitous, increased functionality products at low cost (the internet of things) is spurring development in additive, solution processing of electronic devices. Performance in thin-film functional devices, be they transistors, diodes, or

Absorption Cross Section Measurements of a Human Body in a Reverberation Chamber

February 8, 2016
Author(s)
Damir Senic, Antonio Sarolic, Zbigniew M. Joskiewicz, Christopher L. Holloway
We provide the results of human body absorption cross section (ACS) measurements. The setup was based on the reverberation chamber as a well-known measurement environment capable of performing ACS measurements. The approach was supported by reference

Large-Signal-Network-Analyzer Round Robin

February 1, 2016
Author(s)
Dylan F. Williams, Paul D. Hale, Catherine A. Remley, Gustavo Avolio, Dominique Schreurs, Diogo C. Ribeiro, Pawel Barmuta, Gian Piero Gibiino, Mohammad Rajabi, Arkadiusz Lewandowski, Jaros?aw Szatkowski, Kuangda Wang
This paper describes tests of the calibration-comparison method as an approach to assessing the measurement accuracy of large-signal network analyzer calibrations. We show that having one trusted reference calibration allows the calibration accuracy of the
Displaying 276 - 300 of 1314
Was this page helpful?