Improving Automated Insertion Applications by Restoring Rigid-Body Condition in Point-Based Registration
Published
Author(s)
Geraldine S. Cheok, Marek Franaszek, Karl Van Wyk, Jeremy A. Marvel
Abstract
Accurate knowledge of an object's location is essential in automated robotic applications such as machine tending, pick-and-place operations, and part assembly. Perception systems are used to acquire the object's location, and this information is then passed on to the robot. However, the measured location of the object is in the coordinate frame of the perception system. For the robot to act on the object, the location of the object must be transformed relative to the coordinate frame of the robot. In manufacturing applications that involve industrial robots, a common way to register coordinate frames to each other or to a global frame is by rigid-body, point-based registration using at least three common points or fiducials that are measured in both frames. Researchers at the National Institute of Standards and Technology have developed a method to improve this registration method. The new method restores the rigid-body condition (RRBC). This paper presents an assessment of the NIST RRBC method by conducting practical robotic peg-in-hole experiments. In these experiments, a robot arm was used to insert a peg into a hole. A simple Pass/Fail metric was used to evaluate the effectiveness of the method. The results show that the RRBC reduces the number of failed insertions, especially with tight tolerances.
Cheok, G.
, Franaszek, M.
, Van, K.
and Marvel, J.
(2017),
Improving Automated Insertion Applications by Restoring Rigid-Body Condition in Point-Based Registration, NIST Interagency/Internal Report (NISTIR), National Institute of Standards and Technology, Gaithersburg, MD, [online], https://doi.org/10.6028/NIST.IR.8198
(Accessed October 2, 2025)