Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Journals

Connection between f-electron correlations and magnetic excitations in UTe2

Author(s)
Thomas Halloran, Peter Czajka, Gicela Saucedo Salas, Corey Frank, Jose Rodriguez Rivera, Daniel Mazzonne, Jakob Lass, Nicholas Butch
Abstract The detailed anisotropic dispersion of the low-temperature, low-energy magnetic excitations of the candidate spin-triplet superconductor UTe 2 is...

α-Synuclein interaction with POPC/POPS vesicles

Author(s)
Marija Dubackic, Veronica Lattanzi, Yun Liu, Michael Haertlein, Juliette Devos, Emma Sparr, Sara Linse, Ulf Olsson
We have investigated the interactions between α-Synuclein (aSyn) and small unilamellar vesicles composed of a mixture of zwitterionic POPC and anionic POPS...

Methods to evaluate 3D lidars used for automated driving

Author(s)
Prem Rachakonda, Abhilash Mane, Craig I. Schlenoff, Kamel S. Saidi
Evaluating perception sensor systems for on-road autonomous vehicles is still fraught with ambiguity due to the varying and dynamic environmental factors that...

The Application of Digital PCR as a Reference Measurement Procedure to Support the Accuracy of Quality Assurance for Infectious Disease Molecular Diagnostic Testing

Author(s)
Samreen Falak, Denise O'Sullivan, Megan Cleveland, Simon Cowen, Eloise Busby, Alison Devonshire, Esmeralda Valiente, Gerwyn Jones, Martin Kammel, Mojca Milavec, Laura Vierbaum, Ingo Schellenberg, Heinz Zeichhardt, Andreas Kummrow, Peter Vallone, Rainer Macdonald, Jim Huggett
Background Nucleic Acid Amplification Tests (NAATs) are used to diagnose many infectious diseases. They are typically sensitive and specific and can be quickly...

Interlaboratory Measurement of Adeno-Associated Virus: Comparative Quantification of Full and Empty Capsids

Author(s)
Sean Lehman, Wyatt Vreeland, Jerome Jacques, Sharee Adams-Hall, Shreya Ahuja, Adnan Arnaout, Hunter Balduf, Ivan Budyak, Thomas Cleveland, Dennis Delgado, James Deng, Brandon Doyle, David Duewer, Carsten Elger, Jeffrey Fagan, Tim Guo, Jorge Haller, Luisa Hilgenfeld, Van Hoang, Allison Huldin, Matthew Hyatt, Sambit Kar, Sandeep Kedia, Bashkim Kokona, Amy Liu, Li Ma, Diane McCarthy, He Meng, Easton Noble, Veronika Oettle, Andrew Pla, Thomas Powers, Dean Ripple, Herbert Runnels, Raphael Ruppert, Florian Semmelmann, Christopher Sims, Saurabh Singh, Ronald Toth, Austin Vogt, Sabine Wenzel, Neal Whitaker, Zhiwen Yang, Brandon Zhuang
Recombinant adeno-associated virus (AAV) is one of the main viral vector-based gene therapy platforms. AAV is a virus consisting of a ≈25 nm diameter capsid...

Nagaoka ferromagnetism in 3 × 3 arrays and beyond

Author(s)
Yan Li, Keyi Liu, Garnett Bryant
Nagaoka ferromagnetism (NF) is a long-predicted example of itinerant ferromagnetism (IF) in the Hubbard model that has been studied theoretically for many years...

Disseminable single-photon source for quantum radiometry

Author(s)
Hristina Georgieva, Thomas Gerrits, Lijun Ma, Riley Dawkins, Marco Lopez, Oliver Slattery, Sven Rodt, Stephan Reitzenstein, Alan Migdall, Stefan Kueck
We present a disseminable single-photon source based on an InGaAs quantum dot in a micro-mesa. This source achieves a maximum photon flux of 2.8 million photons...

229ThF4 thin films for solid-state nuclear clocks

Author(s)
Chuankun Zhang, Lars von der Wense, Jack Doyle, Jacob Higgins, Tian Ooi, Hans Friebel, Jun Ye, R. Elwell, J.E.S. Terhune, H.W.T. Morgan, A.N. Alexandrova, H.B. Tran Tan, Andrei Derevianko, Eric R. Hudson

Faint White Dwarf Flux Standards: Data and Models

Author(s)
ralph bohlin, Susana Deustua, ABHIJIT SAHA, Gautham Narayan, Annalisa Calamida, Ivan Hubeny, Thomas Matheson, Armin Rest, Jay Holberg, Karl Gordon, Christopher Stubbs
Abstract Fainter standard stars are essential for the calibration of larger telescopes. This work adds to the calibration spectra (CALSPEC) database of 19 faint...

Recommendations for assessing commutability of a replacement batch of a secondary calibrator certified reference material

Author(s)
Liesbet Deprez, Jesper Johansen, Thomas Keller, Jeffrey Budd, Neil Greenberg, Cas Weykamp, Sverre Sandberg, MAURO PANTEGHINI, Ferruccio Ceriotti, Elizabeth Barczak, Robert Rej, Pernille Kjeilen Fauskanger, Finlay MacKenzie, Johanna Camara, Alicia Lyle, W. Greg Miller, VINCENT DELATOUR
Commutable secondary certified reference materials (CRMs) play an essential role in the calibration hierarchy of many in-vitro diagnostic measurement procedures...
Was this page helpful?