Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Slow- and rapid-scan frequency-swept electrically detected magnetic resonance of MOSFETs with a non-resonant microwave probe within a semiconductor wafer-probing station

Published

Author(s)

Duane J. McCrory, Mark Anders, Jason Ryan, Pragya Shrestha, Kin P. Cheung, Patrick M. Lenahan, Jason Campbell

Abstract

We report on a novel electron paramagnetic resonance (EPR) technique that merges electrically detected magnetic resonance (EDMR) with a conventional semiconductor wafer probing station. This union, which we refer to as wafer-level EDMR (WL-EDMR), allows EDMR measurements to be performed on an unaltered, fully-processed semiconductor wafer. Our measurements replace the conventional EPR microwave cavity or resonator with a very small non-resonant near-field microwave probe. Bipolar amplification effect (BAE), spin dependent charge pumping (SDCP), and spatially-resolved EDMR is demonstrated on various 4H-SiC MOSFET structures. These measurements are made via both "rapid scan" frequency-swept EDMR, and "slow scan" frequency swept EDMR. The elimination of the resonance cavity and incorporation with a wafer probing station greatly simplifies the EDMR detection scheme and offers promise for widespread EDMR adoption in semiconductor reliability laboratories.
Citation
Review of Scientific Instruments
Volume
90
Issue
1

Citation

McCrory, D. , Anders, M. , Ryan, J. , Shrestha, P. , Cheung, K. , Lenahan, P. and Campbell, J. (2019), Slow- and rapid-scan frequency-swept electrically detected magnetic resonance of MOSFETs with a non-resonant microwave probe within a semiconductor wafer-probing station, Review of Scientific Instruments, [online], https://doi.org/10.1063/1.5053665, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=926629 (Accessed October 8, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created January 13, 2019, Updated October 12, 2021
Was this page helpful?