Experiment Name | Plot of Heat Release Rate | Ignition Photo | Date/Time | Project | Specimen Sort descending | Fuel Type | Total Heat Released (MJ) | Peak HRR (kW) |
---|---|---|---|---|---|---|---|---|
Test57_OSB_R3 | Vertical Upward Flamespread on Parallel Panels | 7/16" thick, 24" wide, 96" tall panels of OSB | Oriented Strand Board (OSB) | 262
|
526
|
|||
Test65_RedCedar_R4 | Vertical Upward Flamespread on Parallel Panels | 7/8" thick, 22.5" wide, 96" tall planks of Western Red Cedar | Western Red Cedar | 65.1
|
378
|
|||
Test15_RedCedar_R1 | Vertical Upward Flamespread on Parallel Panels | 7/8" thick, 22.5" wide, 96" tall planks of Western Red Cedar | Western Red Cedar | 139
|
307
|
|||
Test22_RedCedar_R2 | Vertical Upward Flamespread on Parallel Panels | 7/8" thick, 22.5" wide, 96" tall planks of Western Red Cedar | Western Red Cedar | 44.4
|
322
|
|||
Test43_RedCedar_R3 | Vertical Upward Flamespread on Parallel Panels | 7/8" thick, 22.5" wide, 96" tall planks of Western Red Cedar | Western Red Cedar | 38.8
|
398
|
|||
Test9_SIS_wire_R1 | Vertical Upward Flamespread on Parallel Panels | 90 vertically oriented strands of SIS wire | XLPE (SIS Wire) | 16.0
|
132.8
|
|||
Test10_SIS_wire_R2 | Vertical Upward Flamespread on Parallel Panels | 96 vertically oriented strands of SIS wire attached to 1/4" thick, 24" wide, 96"tall panels of GPO-3 | XLPE (SIS Wire) and (GPO-3) | 47
|
142
|
|||
SSEgasBurner3 | Structure Separation Experiments: Shed Burns without Wind | box burner | Natural Gas | 1,268
|
1,019
|
|||
SSEgasBurner0 | Structure Separation Experiments: Shed Burns without Wind | box burner | Natural Gas | 311
|
418
|
|||
SSEgasBurner1 | Structure Separation Experiments: Shed Burns without Wind | box burner | Natural Gas | 742
|
713
|
|||
NGQC_3m_2kgs_400kW_R3 | Natural Gas Confirmation Burner | box burner | Natural Gas | 307.8
|
438
|
|||
SSEgasBurner2 | Structure Separation Experiments: Shed Burns without Wind | box burner | Natural Gas | 712
|
630
|
|||
S01_ISOburn1 | Kitchen Room Fire | Box Burner with Target Wall | Natural Gas | 1,852
|
1,508
|
|||
SB02-ISOburn3 | Kitchen Room Fire | Box Burner with Target Wall | Natural Gas | 2,001
|
1,422
|
|||
SB03b_MildFire | Kitchen Room Fire | Box Burner with Target Wall | Natural Gas | 1,395
|
1,792
|
|||
SB04b_ISOFire | Kitchen Room Fire | Box Burner with Target Wall | Natural Gas | 4,167
|
1,402
|
|||
OSB03b_MildFire | Kitchen Room Fire | Box Burner with Target Wall | Natural Gas | 1,448
|
1,852
|
|||
OSB04b_ISOFire | Kitchen Room Fire | Box Burner with Target Wall | Natural Gas | 4,803
|
2,156
|
|||
OSB05b_MildFire | Kitchen Room Fire | Box Burner with Target Wall | Natural Gas | 1,430
|
1,793
|
|||
S03b_MildFire | Kitchen Room Fire | Box Burner with Target Wall | Natural Gas | 1,439
|
1,822
|
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)