FCD Experiments

Search the title, description, test director, specimen, fuel type, and ignition.
Experiment Name Plot of Heat Release Rate Ignition Photo Date/Time Project Specimen Fuel Type Sort descending Total Heat Released (MJ) Peak HRR (kW)
Test45_HIPS_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of HIPS High Impact Polystyrene (HIPS)
509
2,955
Test46_HIPS_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
NTP Time Query Failed!
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of HIPS High Impact Polystyrene (HIPS)
504
3,228
Test66_HIPS1panel_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels one 1/4" thick, 24" wide, 96" tall panel of HIPS High Impact Polystyrene (HIPS)
274
1,465
Test29_Kydex_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of Kydex Kydex (PVC-acrylic copolymer)
111
1,060
Test30_Kydex_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of Kydex Kydex (PVC-acrylic copolymer)
182
1,070
BSEE_Test_001
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
gravel burner Methane
18.4
39.1
BSEE_Test_002
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
gravel burner Methane
2.24
44.0
Methanol_1m_Pool_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Characteristics of a 1 m Methanol Pool Fire 1 m diameter pool burner Methanol
753
282
Methanol_1m_Pool_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Characteristics of a 1 m Methanol Pool Fire 1 m diameter pool burner Methanol
1,243
279
NGQC_6m_draftflow_250kW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner Tube Burner Natural Gas
150.3
281.3
NGCal15m20MWburner2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
22,938
22,018
CompositeFloorTest_No2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Steel-Concrete Composite Floor Systems Subject to Fire, Phase 2 Four square burners Natural Gas
86,908
12,776
NGQC_3m_3kgs_500kW_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner Tube Burner Natural Gas
403
552
SSEgasBurner0
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind box burner Natural Gas
311
418
NGCal_6m_3MW_16kgs
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
1,932
3,159
SSEgasBurner1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind box burner Natural Gas
742
713
NGCal_6m_3MW_16kgs
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) tube gas burner Natural Gas
1,932
3,159
NGQC_3m_2kgs_400kW_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner box burner Natural Gas
307.8
438
NGQC_6m_20kgs_3MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry tube gas burner Natural Gas
2,372
3,094
SSEgasBurner2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind box burner Natural Gas
712
630

Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077

NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314