Standard Operating Procedures for Smolder Ignition Testing of Upholstery Fabrics

Published

Author(s)

Rick D. Davis, Mauro Zammarano, Szabolcs Matko, Roland H. Kraemer

Abstract

This manuscript describes a methodology to measure the influence of an upholstery cover fabric to promote smoldering mass loss of a small-scale mock-up. The primary test metric is total mock-up mass loss after 45 min exposure to the smoldering ignition source. The testing materials are available through NIST as Standard Reference Material (SRM) 1202: Fabric Smoldering Ignition Testing Materials.
Citation
Technical Note (NIST TN) - 1775
Report Number
1775

Keywords

Polyurethane foam, smoldering, furniture, flammability, SRM 1202¿

Citation

Davis, R. , Zammarano, M. , Matko, S. and Kraemer, R. (2012), Standard Operating Procedures for Smolder Ignition Testing of Upholstery Fabrics, Technical Note (NIST TN), National Institute of Standards and Technology, Gaithersburg, MD, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=912584 (Accessed April 17, 2024)
Created December 11, 2012, Updated February 19, 2017