February 15, 2018
Author(s)
Daniel S. Hussey, Hong Yao, Adam J. Brooks, Ali Haghshenas, Jumao Yuan, Caroline G. Lowery, Jacob M. LaManna, David L. Jacobson, Nikolay Kardjilov, Shengmin Guo, Michael M. Khonsari, Leslie G. Butler
Fatigue in selective laser melted (SLM) and conventional SS316 dogbones was studied with neutron imaging methods for attenuation, scattering, and diffraction. To detect the microcrack evolution in fatigued samples,two methods of grating-based neutron