High Pressure Release and Dispersion of Hydrogen in a Partially Enclosed Compartment

March 1, 2011
Author(s)
Kuldeep R. Prasad, Thomas G. Cleary, William M. Pitts, Jiann C. Yang
The study of compressed hydrogen release from high-pressure storage systems has practical application for hydrogen and fuel cell technologies. Such releases may occur either due to accidental damage to a storage tank or connecting piping, or direct PRD

Fire Spread and Growth on Flexible Polyurethane Foam

October 18, 2009
Author(s)
William M. Pitts, Gregory Hasapis, Patrick Macatangga
A series of experiments designed to characterize fire spread and growth on flat samples of commercial non-fire-retarded flexible polyurethane foam have been performed. 1.2 m × 1.2 m square sections of foam were ignited along one edge, and the fire spread

NUMERICAL SIMULATION OF FIRE SPREAD ON POLYURETHANE FOAM SLABS

March 17, 2009
Author(s)
Kuldeep R. Prasad, Roland Kramer, Nathan D. Marsh, Marc R. Nyden, Thomas J. Ohlemiller, William M. Pitts, Mauro Zammarano
The NIST Fire Dynamics Simulator (FDS) is used extensively by the fire protection engineer for performance based design and forensic analysis. The equations of motion describing the gas phase are relatively well known and the approximations in the various

Structural Fire Response and Probable Collapse Sequence of World Trade Center Building 7 (Volume 1). Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NIST NCSTAR 1-9) ***DRAFT for Public Comments***

August 1, 2008
Author(s)
Therese P. McAllister, Richard G. Gann, Jason D. Averill, John L. Gross, William L. Grosshandler, James R. Lawson, Kevin B. McGrattan, William M. Pitts, Kuldeep R. Prasad, Fahim Sadek, Harold E. Nelson
This is the primary technical report on the National Institute of Standards and Technology (NIST) investigation of the collapse of World Trade Center Building 7 (WTC 7), conducted under the National Construction Safety Team Act. The investigation

Structural Fire Response and Probable Collapse Sequence of World Trade Center Building 7 (Volume 2). Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NIST NCSTAR 1-9) ***DRAFT for Public Comments***

August 1, 2008
Author(s)
Therese P. McAllister, Richard G. Gann, Jason D. Averill, John L. Gross, William L. Grosshandler, James R. Lawson, Kevin B. McGrattan, William M. Pitts, Kuldeep R. Prasad, Fahim Sadek, Harold E. Nelson
This is the primary technical report on the National Institute of Standards and Technology (NIST) investigation of the collapse of World Trade Center Building 7 (WTC 7), conducted under the National Construction Safety Team Act. The investigation

Round Robin Study of Total Heat Flux Gauge Calibration at Fire Laboratories.

September 1, 2006
Author(s)
William M. Pitts, A V. Murthy, J L. Deris, J R. Filtz, K Nygard, D Smith, I Wetterlund
Total heat flux gauges are widely employed in fire research and fire testing laboratories. Several fire laboratories have developed systems for calibrating these gauges. There are major differences between these calibration facilities, and prior to this

Visual Evidence, Damage Estimates, and Timeline Analysis (Appendices D-G) Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NIST NCSTAR 1-5A)

December 1, 2005
Author(s)
William M. Pitts, Kathryn M. Butler, Valentine Junker
This report summarizes the collection and analysis of visual material used for the National Institute of Standards and Technology (NIST) World Trade Center (WTC) Investigation. The task consisted of four major subtasks: 1) identification, collection, data

Visual Evidence, Damage Estimates, and Timeline Analysis (Chapters 1-8) Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NIST NCSTAR 1-5A)

December 1, 2005
Author(s)
William M. Pitts, Kathryn M. Butler, Valentine Junker
This report summarizes the collection and analysis of visual material used for the National Institute of Standards and Technology (NIST) World Trade Center (WTC) Investigation. The task consisted of four major subtasks: 1) identification, collection, data

Use of Visual Imagery for the NIST World Trade Center Investigation

November 13, 2005
Author(s)
William M. Pitts, Kathryn M. Butler, Valentine Junker
The attack on the World Trade Center (WTC) in New York City on September 11, 2001 by terrorists flying hijacked commercial aircraft into the two towers (WTC 1 and WTC 2) was among the worst building disasters in the history of the United States. In

Reconstruction of the Fires in the World Trade Center Towers. Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NIST NCSTAR 1-5) ***DRAFT for Public Comments***

September 1, 2005
Author(s)
Richard G. Gann, Anthony P. Hamins, Kevin B. McGrattan, George W. Mulholland, Harold E. Nelson, Thomas J. Ohlemiller, William M. Pitts, Kuldeep R. Prasad
The collapses of the World Trade Center towers on September 11, 2001, resulted from a combination of aircraft impact damage and the ensuing fires. This report documents: The information obtained on the factors that affected the nature, duration and

Visual Evidence, Damage Estimates, and Timeline Analysis (Chapters 1-8). Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NIST NCSTAR 1-5A) ***DRAFT for Public Comments***

September 1, 2005
Author(s)
William M. Pitts, Kathryn M. Butler, Valentine Junker
This report summarizes the collection and analysis of visual material used for the National Institute of Standards and Technology (NIST) World Trade Center (WTC) Investigation. The task consisted of four major subtasks: 1) identification, collection, data

Visual Evidence, Damage Estimates, and Timeline Analysis (NIST NCSTAR 1-5A)Chapter 9-Appendices A-M. Federal Building and Fire Safety Investigation of the World Trade Center Disaster

September 1, 2005
Author(s)
William M. Pitts, Kathryn M. Butler, Valentine Junker
This report summarizes the collection and analysis of visual material used for the National Institute of Standards and Technology (NIST) World Trade Center (WTC) Investigation. The task consisted of four major subtasks: 1) identification, collection, data

Round Robin Study of Total Heat Flux Gauge Calibration at Fire Laboratories

October 1, 2004
Author(s)
William M. Pitts, A V. Murthy, J L. de Ris, J R. Filtz, K Nyard, D Smith, I Wetterlund
Total heat flux gauges are widely employed in fire research and fire testing laboratories. Several fire laboratories have developed systems for calibrating these gauges. There are major differences between these calibration facilities, and prior to this