Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 1701 - 1725 of 2737

Reference Ballistic Chronograph

April 30, 2009
Author(s)
Nicholas G. Paulter Jr., Donald R. Larson
A ballistic chronograph with a measurement uncertainty of less than +/- 0.1 m/s has been designed, constructed and tested. Because of this low uncertainty, this chronograph can be used as a reference to calibrate and/or characterize the performance of

Three-Magon Splitting and Confluence Processes for Magnetostatic Backward Volume-Spin-Wave Excitations in Yttrium Iron Garnet Films

April 27, 2009
Author(s)
Pavel Kabos, Cesar O. Ordonez-Romero, Boris A. Kalinikos, Pavol Krivosik, Wei Tong, Carl E. Patton
Brillouin light scattering (BLS) has been used to observe and confirm the existence of nonlinear three magnon splitting and confluence processes for propagating spin waves in the magnetostatic backward volume wave (MSBVW) configuration. Wave vector and

EtherNet/IP Interoperability Recommendations

April 22, 2009
Author(s)
James D. Gilsinn, Kevin Knake
The EtherNet/IP interoperability recommendations are a result of work generated by the ongoing series of EtherNet/IP Implementors Workshops. The recommendations were created to promote EtherNet/IP device interoperability through product functionality

Reference Metrology in a Research Fab: The NIST Clean Calibrations Thrust

April 12, 2009
Author(s)
Ronald G. Dixson, Ndubuisi G. Orji, Joseph Fu, Thomas B. Renegar, Xiaoyu A. Zheng, Theodore V. Vorburger, Albert M. Hilton, Marc J. Cangemi, Lei Chen, Michael A. Hernandez, Russell E. Hajdaj, Michael R. Bishop, Aaron Cordes
In 2004, the National Institute of Standards and Technology (NIST) commissioned the Advanced Measurement Laboratory (AML) – a state-of-the-art, five-wing laboratory complex for leading edge NIST research. The NIST NanoFab – a 1765 m2 (19,000 ft2) clean

An Independent Measurement System for Testing Automotive Crash Warning Systems

April 2, 2009
Author(s)
Sandor S. Szabo, Joseph A. Falco, Richard J. Norcross
This report describes the National Institute of Standards and Technology's role in the Integrated Vehicle-Based Safety Systems (IVBSS) program, a four-year safety initiative sponsored by the United States Department of Transportation (U.S. DOT) to develop

Sensitivity of SEM width measurements to model assumptions

March 31, 2009
Author(s)
John S. Villarrubia, Zejun Ding
The most accurate width measurements in a scanning electron microscope (SEM) require raw images to be corrected for instrumental artifacts. Corrections are based upon a physical model that describes the sample-instrument interaction. Models differ in their

Report on Acceleration Comparison SIM.AUV.V-K1 - Draft B

March 20, 2009
Author(s)
David J. Evans, Adriana Hornikova, Stefan D. Leigh, Andrew L. Rukhin, William E. Strawderman
The first regional key comparison in vibration conducted under the auspices of the Inter-American System of Metrology (SIM) was begun in 1996. The comparison was registered with the International Bureau of Weights and Measures (BIPM) through the

Polymerization Stress Development in Dental Composites: Effect of Cavity Design Factor

March 13, 2009
Author(s)
Joseph M. Antonucci, Anthony A. Giuseppetti, Justin N. O'Donnell, Gary E. Schumacher, Drago Skrtic
Objective: To assess the effect of the cavity design factor (C-factor) on polymerization stress development (PSD) in resin composites. Methods: An experimental resin (BT resin) was prepared, which contained 2,2-bis[p-(2 hydroxy-3 -methacryloxypropoxy

Energy Efficient Lighting - Solid State Luminaires (Handbook 150-1A)

February 27, 2009
Author(s)
C Cameron Miller, Lawrence I. Knab, Ambler Thompson, Jon M. Crickenberger
NIST Handbook 150-1A presents technical requirements and guidance for the accreditation of laboratories under the National Voluntary Laboratory Accreditation Program (NVLAP) Energy Efficient Lighting/Solid State Lighting program. It is intended for

SRM Spotlight

February 18, 2009
Author(s)
Regina R. Montgomery
The SRM Spotlight is a newsletter published by the Measurement Services Division for users of NIST standard reference materials. The Spotlight announces new reference materials and provides information about their use. In addition, this newsletter contains

ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers

January 30, 2009
Author(s)
Balasubramanian Muralikrishnan, Daniel S. Sawyer, Christopher J. Blackburn, Steven D. Phillips, Bruce R. Borchardt, William T. Estler
Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings), and possibly in the calculated lengths of

Dimensional measurement traceability of 3D imaging data

January 19, 2009
Author(s)
Steven D. Phillips, Craig M. Shakarji, Michael Krystek, K Summerhays
This paper discusses the concept of metrological traceability to the SI unit of length, the meter. We describe how metrological traceability is realized, give a recent example of the standardization of laser trackers, and discuss progress and challenges to

Advice from the CCL on the use of unstabilized lasers as standards of wavelength: the helium-neon laser at 633 nm

January 1, 2009
Author(s)
Jack A. Stone Jr., Jennifer Decker, Patrick Gill, Andrew Lewis, Patrick Juncar, Daniele Rovera, Miguel Villiseid
The Consultative Committee for Length has recommended that red (633 nm) unstabilized Helium-Neon lasers, operating on the 3s2¿_2p4 transition, should be included in the list of standard frequencies for realization of the meter. This article discusses

Character contrast

January 1, 2009
Author(s)
Edward F. Kelley
Measurement of a small black area on a white electronic display screen is often accompanied by serious contamination from veiling glare in the detector. The black measurement can be thousands of percent in error. Character-stroke-contrast or small-area

Maintenance and Validation of Liquid-in-Glass Thermometers

January 1, 2009
Author(s)
Christina D. Cross, Dean C. Ripple, Gregory F. Strouse
Liquid-in-glass thermometers are pervasive in use throughout industry and provide a convenient method for measuring temperature over for a broad range of applications with reasonable stability and accuracy. However, liquid-in-glass thermometers are subject
Displaying 1701 - 1725 of 2737