Infrared Imaging and Spectroscopy Beyond the Diffraction Limit

July 22, 2015
Author(s)
Andrea Centrone
Progress in nanotechnology is enabled by and dependent on the availability of measurement methods with spatial resolution commensurate with nanomaterials’ length scales. Chemical imaging techniques, such as scattering scanning near-field optical microscopy

Direct Measurement of Trace Polycyclic Aromatic Hydrocarbons in Diesel Fuel with 1H and 13C NMR Spectroscopy: Effect of PAH Content on Fuel Lubricity

June 17, 2015
Author(s)
Peter Y. Hsieh, Jason A. Widegren, Andrew Slifka, Andrew J. Hagen, Ronald A. Rorrer
Surface-active trace compounds present in diesel fuels protect pumps and injectors against premature wear through boundary lubrication. Due to the vast number of hydrocarbon compounds found in petroleum distillate fuels, it is difficult to measure the

Analysis of Several High-Resolution Bands of Spiropentane, C5H8

June 15, 2015
Author(s)
Alfons Weber, A. Maki, J. E. Price, Jared Harzan, J. W. Nibler, T. Masiello, T Blake
The high resolution absorption spectrum of spiropentane (C5H8) from 200 cm-1 to 4000 cm−1 has been measured and a detailed analysis is presented for eight bands in the region from 700 cm−1 to 2200 cm−1. Two fundamental perpendicular bands were analyzed

COMMON SPURIOUS SIGNALS OBSERVED IN MASS SPECTROMETERS

June 1, 2015
Author(s)
Thomas J. Bruno, Paris D. Svoronos-Cambanas
The following table provides guidance in the recognition and interpretation of spurious signals (m/z peaks) that will sometimes be observed in mass spectra, especially mass spectra obtained from gas chromatography mass spectrometry systems (GC-MS) [1,2]

SOLID PHASE MICROEXTRACTION SORBENTS

June 1, 2015
Author(s)
Thomas J. Bruno, Paris D. Svoronos Cambanas
While trapping sorbents have been used for many years in headspace analysis (most commonly with gas chromatography), the modern techniques of solid phase microanalysis (SPME) are particularly applicable to survey analyses [1]. In the following tables, we

STATIONARY PHASES FOR POROUS LAYER OPEN TUBULAR COLUMNS

June 1, 2015
Author(s)
Thomas J. Bruno, Paris D. Svoronos Cambanas
The practical application of solid adsorbents in capillary chromatography typically makes use of porous layer open tubular (PLOT) columns. Early capillary PLOT columns suffered from detector spiking due to particulates becoming dislodged and entering the