Displaying 48926 - 48950 of 143775

Comparison of Microwave Black-Body Target Radiometric Measurements

July 30, 2010
Author(s)
Dave K. Walker, Dazhen Gu, Katherine MacReynolds, Randy Direen, James P. Randa, Amanda Cox, Derek A. Houtz, Robert L. Billinger
Accurate characterization of the brightness temperature (T_B) of black-body targets used for calibrating microwave remote-sensing radiometers includes many inputs: antenna pattern and loss, target temperature, target emissivity, mechanical alignment, and

Investigation into the Standardization of Tc-99

July 30, 2010
Author(s)
Lizbeth Laureano-Perez, Ronald Colle, Ryan P. Fitzgerald, Brian E. Zimmerman, Lonnie T. Cumberland
The standardization of 99Tc by several primary methods was investigated. This was performed to support a new 99Tc transfer standard that has been developed and will be disseminated by the National Institute of Standards and Technology (NIST) as Standard

Metrology of Microstructured Waveguides for Spintronic Applications

July 30, 2010
Author(s)
SangHyun S. Lim, Atif A. Imtiaz, Dazhen Gu, Pavel Kabos, Thomas Mitchell (Mitch) Wallis
Patterned permallay films as a part of a coplanar waveguide (CPW) were fabricated, and the magnetization dynamics of such structures was investigated as fundamental building blocks for magnetic spintronic devices. Anisotropic magneto-resistance (AMR)

Micro-feature dimensional and form measurements with the NIST fiber probe on a CMM

July 30, 2010
Author(s)
Balasubramanian Muralikrishnan, Jack A. Stone Jr., John R. Stoup, Chittaranjan Sahay
The NIST fiber probe is a Coordinate Measuring Machine (CMM) probing system intended for diameter and form measurement of micro features and small holes. This Moore M48 CMM at NIST can measure holes down to 500 um diameter with the Movamatic probe; the

REFLECTIVITY STUDIES OF PASSIVE MICROWAVE CALIBRATION TARGETS AND ABSORPTIVE MATERIALS

July 30, 2010
Author(s)
Dazhen Gu, Amanda Cox, Derek A. Houtz, Dave K. Walker, James P. Randa, Robert L. Billinger
We report the characterization of blackbody reflections as a part of the recent progress on the development of brightness standards for microwave remote sensing at National Institute of Standards and Technology (NIST).Three blackbody targets at variable

Use of Electronic Calibration Units for Vector-Network-Analyzer Verification

July 30, 2010
Author(s)
Dylan F. Williams, Arkadiusz C. Lewandowski, Denis X. LeGolvan, Ronald A. Ginley, Chih-Ming Wang, Jolene D. Splett
We present measurements indicating that electronic calibration units are stable enough to be used in place of mechanical vector-network-analyzer verification artifacts. This enables a new fully automated approach to verifying microwave vector-network

Using Microfluidic Channels to Determine ZThe Quantitative Permittivity of Nanoliter Fluid Volumes from 50 MHz TO 40 GHz USING MICROFLUIDIC CHANNELS TO DETERMINE THE QUANTITATIVE PERMITTIVITY OF NANOLITER FLUID VOLUMES FROM 50 MHZ TO 40 GHZ

July 30, 2010
Author(s)
James C. Booth, Nathan D. Orloff, Xiaoli Lu, Yu Y. Wang, Eduard Rocas, Jordi Mateu, Juan C. Collado Gomez, Michael D. Janezic
We describe the development of coplanar waveguide measurement structures integrated with microfluidic channels in order to rapidly determine the broadband dielectric properties of nanoliter volumes of fluids, fluid mixtures, and colloids over the range of

Examining the True Effectiveness of Loading a Reverberation Chamber

July 29, 2010
Author(s)
Jason Coder, John M. Ladbury, Christopher L. Holloway, Kate Remley
In this paper we explore how placing the same amount of absorber in different locations within a reverberation chamber can have different loading effects. This difference can have a significant impact on measurement reproducibility, both for measurements

SEABIRD TISSUE ARCHIVAL AND MONITORING PROJECT: Project Overview, and Updated Protocols for Collecting and Banking Seabird Eggs

July 29, 2010
Author(s)
Lauren B. Rust, Rebecca S. Pugh, Amanda J. Moors, Stacy S. Schuur, David G. Roseneau, Paul R. Becker
The Seabird Tissue and Archival Monitoring Project (STAMP) is a collaborative effort by the U.S. Fish and Wildlife Service (USFWS), the Alaska Maritime National Wildlife Refuge (AMNWR), and the National Institute of Standards and Technology (NIST) to

Converting Technical Content to Training Material

July 28, 2010
Author(s)
Georgia L. Harris, Dana S. Leaman
This paper provides the basis for an interactive mini tutorial and covers how to convert technical content to training materials. It includes: defining the audience, writing learning objectives, designing content and activities to achieve objectives