Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 14126 - 14150 of 17285

Verification of Calibration Methods for Determining Photon-Counting Detection Efficiency using Superconducting Nano-Wire Single Photon Detectors

September 4, 2017
Author(s)
Igor Vayshenker, Robert D. Horansky, John H. Lehman, Malcolm G. White, Sae Woo Nam, Ingmar Mueller, Lutz Werner, G. Wuebbeler
In the recent years several ways to radiometrically calibrate optical fiber-coupled detectors have been developed. However, fiber-coupled calibration methods for single photon detectors have not been compared by national metrology institutes validating the

Successive Field-Induced Transitions in BiFeO 3 Around Room Temperature

July 21, 2017
Author(s)
Shiro Kawachi, Atsushi Miyake, Toshimitsu Ito, Sachith E. Dissanayake, Masaaki Matsuda, William D. Ratcliff, Yang Zhao, Shin Miyahara, Masashi Tokunaga
The Effects of high magnetic fields applied perpendicular to the spontaneous ferroelectric polarization on single crystals of BiFeO 3 were investigated through magnetization, magnetostriction, and neutron diffraction measurements. The magnetostriction

A Direct Error Measure for Affine Models of Nonlinear Algebraic Systems

February 19, 2017
Author(s)
D M. Lorenzetti
This paper proposes a measure of the deviation between a nonlinear equation and its affine model, and demonstrates applications to nonlinear systems. The measure expresses the model error relative to a representative change in its predicted value

ICSD Accessibility in Support of Materials Research and Design

February 19, 2017
Author(s)
Vicky L. Karen, A J. Belsky
The materials community in both science and industry use crystallographic data models on a daily basis to visualize, explain, and predict the behavior of chemicals and materials. Access to reliable information on the structure of crystalline materials

Navigation Performance Evaluation for Automated Guided Vehicles

May 12, 2015
Author(s)
Roger V. Bostelman, Tsai Hong Hong, Geraldine S. Cheok
Automatic guided vehicles (AGVs), an industrial form of mobile robot, typically navigate using a central computer commanding AGV movement on predefined paths. Although, how well they follow these paths is less defined in research articles and their

Light shifts in a pulsed cold-atom coherent-population-trapping clock

April 10, 2015
Author(s)
Eric M. Blanshan, Elizabeth A. Donley, John E. Kitching
Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in a variety of applications. A cold-atom coherent population trapping clock featuring laser-cooled 87Rb atoms and pulsed Ramsey

Photon-noise limited sensitivity in titanium nitride kinetic inductance detectors

February 20, 2015
Author(s)
Johannes Hubmayr, James A. Beall, Daniel T. Becker, Hsiao-Mei Cho, Gene C. Hilton, Dale Li, David P. Pappas, Jeffrey L. Van Lanen, Mark Devlin, Kent D. Irwin, Chris Groppi, Phillip Mauskopf
We demonstrate photon-noise limited performance at sub-millimeter wavelengths in microwave kinetic inductance detectors (MKIDs) made of a new superconducting material, a TiN/Ti/TiN trilayer film. Optical coupling is achieved by use of feedhorns, a standard

Volumetric Performance Evaluation of a Laser Scanner Based on Geometric Error Model

January 5, 2015
Author(s)
Balasubramanian Muralikrishnan, Massimiliano M. Ferrucci, Daniel S. Sawyer, Grant Gerner, Vincent D. Lee, Christopher J. Blackburn, Steven D. Phillips, Yuri Yakovlev, Andrey Astrelin, Spike Milligan, John Palmateer
… and therefore in the development of documentary Standards. The work described in this paper lays the …

Picometer Metrology for Precise Measurement of Refractive Index, Pressure, and Temperature

December 18, 2013
Author(s)
Jack A. Stone Jr., Patrick F. Egan, Donavon Gerty, Jay H. Hendricks, Douglas A. Olson, Jacob E. Ricker, Gregory E. Scace, Gregory F. Strouse
Fabry-Perot interferometers can be used for very precise measurement of the refractive index of gasses. This can enable increased accuracy of interferometer-based length measurement. In addition, because the refractive index of a gas depends on its

Absolute calibration of optical power and fluence rate for PDT: Report of AAPM TG140

July 23, 2013
Author(s)
Marla L. Dowell, Timothy Zhu, Christopher Bonnerup, Valdir Colussi, Jarod Finlay, Lothar Lilge, Thomas Slowery, claudio sibata
This report is primarily concerned with methods for optical calibration of laser power and light fluence rate for continuous wave (CW) light sources, predominantly used in photodynamic therapy (PDT). Dosimetry of light is very important for PDT, however

In-plane Rotation and Scale Invariant Clustering and Dictionary Learning

June 3, 2013
Author(s)
P J. Phillips, Challa Sastry, Yi-Chen Chen, Vishal M. Patel, Rama Chellappa
n this paper, we present an approach that simulta- neously clusters images and learns dictionaries from the clusters. The method learns dictionaries in the Radon transform domain, while clustering in the image domain. The main feature of the proposed
Displaying 14126 - 14150 of 17285
Was this page helpful?