Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Electromigration of Cu Interconnects Under AC, Pulsed-DC and DC Test Conditions - Ramifications on Accelerated Testing

Published

Author(s)

Robert R. Keller, David T. Read, Roey Shaviv, Greg Harm, Sangita Kumari

Abstract

Electromigration (EM) of a dual damascene, single-via fed, test vehicle was measured using DC, AC followed by DC, and three rectangular-wave DC stressing conditions at 598 K. In some of the experiments samples were allowed to cool between stress cycles. Void formation and migration inside Cu interconnects were filmed. We show void formation by AC and void migration and consolidation by DC. We found that neither AC stressing followed by DC stressing to failure nor DC coupled with thermal cycling had an effect on the net, DC only, EM performance. All tests, regardless of thermal history and current cycling conditions, resulted in similar DC lifetimes and their distributions. We conclude that for this test structure, only net DC testing time has a significant effect on time to failure. AC stress, thermal history (including cooling to room temperature) and pulsed DC stressing have no effect on electromigration lifetime under DC conditions. We further conclude that the standard test methodologies, using accelerated DC stress conditions at elevated temperatures, are adequate. However, since only the net DC stress time has any measurable effect on EM lifetime, accelerated testing provides a good predictor for lifetime expectations only for the DC component of continuous operating conditions, but underestimates lifetime expectation under pulsed DC, and variable usage operating conditions by 50 % or more, depending on duty cycle. We also conclude that neither AC stress nor DC cycling, and changes to grain structure that may result, vaccinate Cu interconnects against EM failures and thus, do not provide any measurable benefit to net, DC only, EM lifetime.
Proceedings Title
2011 IEEE International Reliability Physics Symposium
Conference Dates
April 12-14, 2011
Conference Location
Monterey, CA

Keywords

AC, accelerated testing, DC, electromigration

Citation

Keller, R. , Read, D. , Shaviv, R. , Harm, G. and Kumari, S. (2011), Electromigration of Cu Interconnects Under AC, Pulsed-DC and DC Test Conditions - Ramifications on Accelerated Testing, 2011 IEEE International Reliability Physics Symposium, Monterey, CA, [online], https://doi.org/10.1109/IRPS.2011.5784570 (Accessed December 10, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created April 10, 2011, Updated November 10, 2018