Experiment Name Plot of Heat Release Rate Ignition Photo Date/Time Project Specimen Fuel Type Total Heat Released (MJ) Peak HRR (kW) Sort descending
Test48_XPSpink1_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1" thick, 24" wide, 96" tall panels of Pink XPS Foam Extruded Polystyrene Foam (XPS)
55.3
1,332
SB04b_ISOFire
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
4,167
1,402
Test15_4woodCrib_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry wood cribs Cellulose
2,523
1,402
1B-SCh0-0
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind Steel Shed Wood Cribs Cellulose
1,170
1,404
SB02-ISOburn3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
2,001
1,422
Test64_XPSgreen2_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 2" thick, 24" wide, 96" tall panels of Green XPS Foam Extruded Polystyrene Foam (XPS)
97.8
1,426
Test27_4plasticCommodity_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry cardboard boxes filled with polystyrene cups Cellulose, Polystyrene
700
1,430
Test66_HIPS1panel_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels one 1/4" thick, 24" wide, 96" tall panel of HIPS High Impact Polystyrene (HIPS)
274
1,465
S01_ISOburn1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
1,852
1,508
Test54_XPSpink2_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 2" thick, 24" wide, 96" tall panels of Pink XPS Foam Extruded Polystyrene Foam (XPS)
84.5
1,510
B5-1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Fire Barriers in Full-Scale Chair Mock-ups upholstered chair mockup Polyurethane Foam
327
1,547
Test63_XPSpink2_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 2" thick, 24" wide, 96" tall panels of Pink XPS Foam Extruded Polystyrene Foam (XPS)
93.2
1,580
CornerTest1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Cross Laminated Timber Compartments room corner mockup Cellulose, Plastic
1,522
1,624
Test41_XPSPink2_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 2" thick, 24" wide, 96" tall panels of Pink XPS Foam Extruded Polystyrene Foam (XPS)
100.6
1,687
SB03b_MildFire
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
1,395
1,792
OSB05b_MildFire
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
1,430
1,793
Test6_4Pallet_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry wood pallets and paper Cellulose
1,073
1,801
S03b_MildFire
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
1,439
1,822
Test55_XPSgreen2_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 2" thick, 24" wide, 96" tall panels of Green XPS Foam Extruded Polystyrene Foam (XPS)
110
1,839
OSB03b_MildFire
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
1,448
1,852

Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077

NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314