NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Tip Characterization for Scanned Probe Microscope Width Metrology
Published
Author(s)
Samuel Dongmo, John S. Villarrubia, Samuel N. Jones, Thomas B. Renegar, Michael T. Postek, Jun-Feng Song
Abstract
Determination of the tip shape is an important prerequisite for converting the various scanning probe microscopies form imaging tools into dimensional metrology tools with sufficient accuracy to meet the critical dimension measurement requirements of the semiconductor industry. Determination of the tip shape generally requires that the tip be used to image a tip characterizer. Characterizing the characterizer has itself been an obstacle to progress, since most methods require the geometry of the characterizer to be known with uncertainty small compared to the size of the tip. We have recently developed a blind reconstruction method which allows the 3-dimensional tip shape to be estimated from an image of an unknown characterizer. This method has heretofore been tested only in simulations. We report here initial results of an experimental test of the technique. We compare the reconstructed profile of a tip to an independently measured profile using a scanning electron microscope (SEM). A relatively large (500 nm radius) diamond stylus profiler tip was used in order to test the principle of blind reconstruction in a size regime where SEM instrumental uncertainties are small compared to the tip size. The blind reconstruction and SEM profiles agree well, differing only by an amount comparable to the reproducibility of the stylus profiler images (better than 2% of the sample corrugation in this instance).
Proceedings Title
Characterization and Metrology for ULSI Technology 1998 International Conference
Conference Dates
March 1, 1998
Conference Title
International Conference on Characterization and Metrology for ULSI Technology
Dongmo, S.
, Villarrubia, J.
, Jones, S.
, Renegar, T.
, Postek, M.
and Song, J.
(1998),
Tip Characterization for Scanned Probe Microscope Width Metrology, Characterization and Metrology for ULSI Technology 1998 International Conference
(Accessed October 14, 2025)