Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

In-situ Polarized He3-Based Neutron Polarization Analyzer for SNS Magnetism Reflectometer

Published

Author(s)

W-T Lee, X Tong, J. Pierce, M. Fleenor, A. Ismaili, JL Robertson, Wangchun Chen, Thomas R. Gentile, A. Hailemariam, R J. Goyette, A. Parizzi, V Lauter, F. Klose, H. Kaiser, C. Lavelle, DV Baxter, G L. Jones, J. Wexler, L. McCollum

Abstract

We report here the construction and neutron transmission test results of an in-situ polarized 3He-based neutron polarization analyzer system for the Magnetism Reflectometer at the Spallation Neutron Source, Oak Ridge National Laboratory. The analyzer uses the Spin-Exchange Optical Pumping method to polarize the 3He nuclei of a cell of 3He gas. Polarized neutrons scattered from the sample are intercepted by the polarized 3He gas which strongly absorbs neutrons in one spin-state while allowing most neutrons in the other spin-state to pass through. To maintain a stable analyzing efficiency during an experiment, the 3He gas is continuously polarized in-situ on the instrument. Neutron transmission measurements showed that 73% 3He polarization was reached in this setup.
Citation
Journal of Physics: Conference Series
Issue
251

Keywords

He-3, in-situ, magnetism reflectrometer, neutron polarization

Citation

Lee, W. , Tong, X. , Pierce, J. , Fleenor, M. , Ismaili, A. , Robertson, J. , Chen, W. , Gentile, T. , Hailemariam, A. , Goyette, R. , Parizzi, A. , Lauter, V. , Klose, F. , Kaiser, H. , Lavelle, C. , Baxter, D. , Jones, G. , Wexler, J. and McCollum, L. (2011), In-situ Polarized He3-Based Neutron Polarization Analyzer for SNS Magnetism Reflectometer, Journal of Physics: Conference Series, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=903159 (Accessed October 8, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created January 30, 2011, Updated October 12, 2021
Was this page helpful?