Displaying 226 - 250 of 361

R-22 Replacement Status (in Portuguese) Part 1 and Part 2

March 1, 2005
Author(s)
J M. Calm, Piotr A. Domanski
Since its initial recognition in 1928 and commercialization in 1936, R-22 has been applied in systems ranging from the smallest window air conditioners to the largest chillers and heat pumps, including those for district cooling and heating. Individual

MEMS Sensors for HVAC&R: Small, Fast, Cheap.

December 1, 2004
Author(s)
David A. Yashar, Piotr A. Domanski
Microelectronic mechanical systems (MEMS) have revolutionized the market for sensors by providing small, fast-responding measurement devices at lowcost. They have been widely accepted in several commonproducts. As an example, today’s automobile uses

R-22 Replacement Status

November 1, 2004
Author(s)
J M. Calm, Piotr A. Domanski
Since its initial recognition in 1928 and commercialization in 1936, R-22 has been applied in systems ranging from the smallest window air conditioners to the largest chillers and heat pumps, including those for district cooling and heating. Individual

R-22 Replacement Status (in Chinese)

September 17, 2004
Author(s)
J M. Calm, Piotr A. Domanski
Since its initial recognition in 1928 and commercialization in 1936, R-22 has been applied in systems ranging from the smallest window air conditioners to the largest chillers and heat pumps, including those for district cooling and heating. Individual

R-22 Replacement Status

August 1, 2004
Author(s)
J M. Calm, Piotr A. Domanski
The next step in the transition to environmentally safer refrigerants is phase out of R-22. It is the most widely used refrigerant, both in the United States and on a global basis. Its application range in residential, commercial, industrial, and transport

MEMS Sensors for HVAC&R

May 1, 2004
Author(s)
David A. Yashar, Piotr A. Domanski
MicroElectronic Mechanical Systems (MEMS) have revolutionized the market for sensors by providing small, fast-responding measurement devices at very low cost. These measurement devices have been widely accepted in many areas of engineering and have vastly

An Optimized Design of Finned-Tube Evaporators Using the Learnable Evolution Model

April 1, 2004
Author(s)
Piotr A. Domanski, David A. Yashar, Kenneth Kaufman, RK S. Michalski
Optimizing the refrigerant circuitry for a finned-tube evaporator is a daunting task for traditional exhaustive search techniques due to the extremely large number of circuitry possibilities. For this reason, more intelligent search techniques are needed